1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-)
2. Connect the OUTPUT 1 N/O and COM to OPEN contacts in the operator
(see operator manufacturer’s manual for proper terminals)
3. To Enter Programming mode: Press 0000 *
(This is the factory set Master Code change for security)
4. The KPX 100 is shipped in multi user mode from the factory
5. To set PERSONAL MASTER CODE: Press 0 and 4-8 digits and #
To program Relay 1 users
6. To set USER CODE 1: Press 1 then 00 and 4 to 8 digits and #
7. To set USER CODE 2: Press 1 then 01 and 4 to 8 digits and #
8. To set USER CODE 3: Press 1 then 02 and 4 to 8 digits and #
9. Continue as needed up to 100 codes: (00 - 99)
10. To set OUTPUT for 10 seconds: Press 402 then #
(40 is output program code. Time may be from 1 –999 seconds)
11. To Place Relay 1 in Toggle or Latch Mode: Press 41 then #
12. To deactivate the need to press the # key for access codes: Press 82 1 then #
(When using automatic mode the "bypass # to activate" the user codes must be same number of digits as master code)
13. To Exit programming: Press *
For additional detailed information regarding additional functions, connection to door controls, alarms and trouble shooting please refer to the
manual. (see index)
0
0
0
0
*
Optional additional digits
?
?
?
?
?
?
?
?
1
0
1
#
Optional additional digits
?
?
?
?
?
?
?
?
1
0
2
#
Optional additional digits
0
?
?
?
?
?
?
?
?
#
*This must be done after changing modes Record the new code
Location
codes
Pg 1
Note: Each successful program action
is followed by (2) "beeps" confirming
acceptance

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
*
4
1
#
4
0
0
#
1
1
#
?
?
?
?
2
#
?
?
?
?
#
8
9
0
0
KPX 100 Quick Start For Single-User Mode
1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-)
2. Connect the OUTPUT 1 N/O and COM to OPEN contacts in the operator
(see operator manufacturer’s manual for proper terminals)
3. To Enter Programming mode: Press 0000 *
(This is the factory set Master Code change for security)
4. The KPX 100 is shipped in multi user mode from the factory
5. To change to Single User Mode: Press 8900 then #
6. To set PERSONAL MASTER CODE: Press 0 and 4 digits and #
To program Relay users
7. To set USER CODE Relay 1: Press 1 then 4 digits and #
8. To set USER CODE Relay 2: Press 2 then 4 digits and #
9. To set OUTPUT for 10 seconds: Press 402 then #
(40 is output program code. Time may be from 1 –999 seconds)
10. To Place Relay 1 in Toggle or Latch Mode: Press 41 then #
11. To Exit programming: Press *
For additional detailed information regarding additional functions, connection to door controls, alarms and trouble shooting please refer to the
manual. (see index)
0
0
0
0
*
Pg 2
0
?
?
?
?
#
*This must be done after changing modes Record the new code
Note: Each successful program action
is followed by (2) "beeps" confirming
acceptance

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
Pg 3
D.A.P. Reset see
Page 5

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
Pg 4

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
Pg 5
0
?
?
?
?
#
*This must be done after DAP reset
Record the new code

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
0
0
0
0
*
Set system into programming mode with factory set master code.
8
9
0
0
8
9
0
1
#
#
Set system to single user mode, clear all previous data & refreshes system
Set system to multi user mode, clear all previous data & refreshes system
4
0
4
1
4
2
1 to 999
#
#
#
Output 1 in momentary mode from 1 to 999 seconds
Output 1 in Start / Stop Mode (toggle)
Output 1 in Start / Stop Mode (toggle) with
accelerated code
5
0
5
1
5
2
1 to 999
#
#
#
Output 2 in momentary mode from 1 to 999 seconds
Output 2 in Start / Stop Mode (toggle)
Output 2 in Start / Stop Mode (toggle) with
accelerated code
0
2
#
#
#
4 digits, fixed
4 digits, fixed
4 digits, fixed
Personal Master Code & Super User Code
User Code 1 for output 1 with Duress Code function
User code 2 for output 2
1
Personal Master Code & Super User Code
#
100 User codes in Group 1 for output 1 with
Duress Code function
0
1
2
00 to 99
0 to 9
4 to 8 digits
4 to 8 digits
4 to 8 digits
10 User Codes in Group 2 for output 2
#
#
i)
ii)
Pg 6

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
7
0
7
1
7
2
7
6
5 to 10
00
#
#
#
#
After 10 successive false codes, keypad will lock
for 30 seconds
After 10 successive false codes, the Duress output
switches to ground
Selectable from 5 to 10 successive false codes, the
keypad locks for 15 minutes. The keypad can be
reset to release lock with the Master Code at any
time during the locking period.
Removal of all above security settings
8
0
8
0
#
#
1
0
Door Forced Open Alarm is Activated
Door Forced Open Alarm is Disabled
8
1
1
#
1 second notification beep is given to notify the
person outside to open the door when output
relay is activated with a user code or egress
button. Good for the locking device that gives no
sound when it activates, such as magnetic lock.
8
1
0
#
Notification beep disabled and replaced by 2
short successful code entry beeps for valid
user codes.
8
2
1
#
Auto Entry Mode is selected. Key that follows
the user code is not required in code entry. The user
codes must be set in the same digit length as the
Master Code in Auto Entry mode and the code can be
4-8 digits
8
2
0
#
Manual Entry Mode is selected. Key that follows
the user code is required in code entry. The user codes
can be 4-8 digits and are not required to be the same
length as the Master Code.
#
#
Pg 7

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
8
3
8
3
1
0
#
#
Tones are active on key press
Tones are off. Use for silent environment requirements
9
9
#
#
No Propped Open Alarm
Time from 1 to 999 seconds until door
propped open activates alarm
0
1 to 999
*
Keypad exits programming mode and returns to normal operation
Pg 8

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
MASTER CODE
*
8
9
0
0
#
MASTER CODE
*
8
9
0
1
#
Pg 9

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
*
MASTER CODE
*
LOCATION 1
#
OPTION
LOCATION n
#
OPTION n
*
Pg 10

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
0
0
0
0
*
-----------
8
9
0
0
#
-----------
0
3
2
8
9
1
8
3
2
1
#
#
---
---
2
6
8
5
4
#
---
4
0
1
#
Output 1 has been set to momentary mode with 1 second duration
5
1
#
-------------------
Output 2 has been set to Start / Stop (toggle) mode
7
2
1
0
#
---------
*
----------------------------
*
#
8
3
2
1
6
8
5
4
---------
---------
Output 1 activates for 1 second
Output 2 Starts or Stops (toggle mode)
#
8
3
2
1
---------
Output 1 activates for 1 second
8
3
2
1
---------
Output 2 Starts or Stops (toggle mode)
#
#
1
2
0
3
2
1
---------
Duress output activates (output switches to (-) ground) & Output 1
activates for 1 second
Pg 11

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
8
3
#
8
3
2
1
---------
---------
Output 1 starts
Output 1 stops
3
2
8
9
---------
Lockout is reset and keypad resumes normal operation
#
Pg 12

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
0
0
0
0
---------
System is set to programming mode using factory set Master User Code
*
8
9
0
1
---------
System is set to Multi-User Mode *8 (see note (a) below
#
0
3
2
8
--------
3289 has been stored as the new Personal Master Code & Super User Code
#
9
1
8
3
2
--------
8321 has been stored as 1st user code in Group 1 with duress
code function
#
1
0
1
1
3
3
2
--------
33221 has been stored as 3rd user code in Group 1 with
duress code function
#
2
0
3
1
2
6
8
--------
6854 has been stored as 1st user code in Group 2
#
5
1
4
2
5
4
3
--------
54321 has been stored as 2nd user code in Group 2
#
2
2
1
4
----------------------------
Output 1 is set to Momentary Mode with 1 second duration
#
0
1
5
---------------------------------
Output 2 is set to Toggle Mode
#
1
7
-------------------------
Keypad is set to lock for 15 minutes after 10 successive false
codes
#
2
1
0
*
-----------------------------------
#
#
8
3
2
1
#
-----------------------------------
Output 1 activates for 1 second
1
1
2
1
#
-------------------------------
Output 1 activates for 1 second
3
3
3
2
2
#
-------------------------------
Output 1 activates for 1 second
1
#
6
8
5
4
#
-----------------------------------
Output 2 Starts or Stops (toggle mode)
5
4
3
2
Output 2 Starts or Stops (toggle mode)
1
#
--------------------
1
1
1
2
--------
11223 has been stored as 2nd user code in Group 1 with
duress code function
#
2
0
2
3
Pg 13

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
#
-------------------------------
0
3
2
1
#
---
Duress output activates (switches to ground) & Output 1 activates for 1 second
3
1
2
2
#
---
Duress output activates 9 switches to ground) & Output 1 activates for 1 second
3
5
3
2
2
#
---
Duress output activates 9 switches to ground) & Output 1 activates for 1 second
1
8
3
#
8
3
2
1
--------------------
-------------
Output 1 starts
Output 1 Starts
Output 1 Stops
1
1
Output 1 Starts
1
1
2
2
---------
Output 1 Stops
3
#
#
#
3
2
8
9
#
-------------------------------
Output 1 activates for 1 second
1
3
2
8
9
#
-------------------------------
Output 2 Starts or Stops (toggle mode)
2
Pg 14

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
3
2
8
9
---------
Lockout is reset and keypad resumes normal operation
#
*
3
2
8
9
---------
Keypad is now in Programming Mode
*
#
1
0
5
#
2
3
#
*
Pg 15

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
Pg 16

KPX 100 Instuctions.doc Rev 1.6 7/10//2018
(B) DOOR SENS
a) Door Auto Relock –the system will
immediately re-lock the door after a valid
access has been gained to prevent “tailgate”
entry.
b) Door Forced-open alarm –The keypad will
generate an instant alarm if the door is
forced to open. Enable the function with
Program Option 801
c) Door Propped Open Alarm –The keypad
will generate an alarm if the door is left
open longer than the pre-set time. Enable
the function with Program Option 9 with
duration of 1 to 999 seconds.
With the help of a normally closed door d) Inter-lock Control –When the door is open
Position sensor (usually a magnetic door the inter-lock output of the keypad will give
switch)on the door to set up the following a (-) command to de-activate the other
functions. keypad in an inter-lock system.
Pg 17
Other manuals for KPX 100
1
Table of contents
Other EMX Industries, Inc. Keypad manuals
Popular Keypad manuals by other brands

ADEMCO
ADEMCO 6137 installation guide

Salto
Salto CONLAN CM1000EMV user manual

Select Engineered Systems
Select Engineered Systems SPRFC1 user manual

urmet domus
urmet domus FDI K-PAD Install & user's guide

CDVI
CDVI Krypto K3 Quick start installation guide

Assa Abloy
Assa Abloy S series Installation & programming guide