Proline Promag W 500
2 Endress+Hauser
Table of contents
About this document ........................ 4
Symbols used ................................ 4
Function and system design ................... 5
Measuring principle ............................ 5
Measuring system ............................. 6
Equipment architecture ......................... 8
Safety ..................................... 8
Input .................................... 10
Measured variable ............................ 10
Measuring range ............................. 10
Operable flow range ........................... 12
Input signal ................................ 12
Output .................................. 14
Output and input variants ....................... 14
Output signal ............................... 15
Signal on alarm .............................. 18
Ex connection data ........................... 21
Low flow cut off ............................. 22
Galvanic isolation ............................ 22
Protocol-specific data .......................... 22
Power supply ............................. 27
Terminal assignment .......................... 27
Device plugs available .......................... 28
Pin assignment, device plug ...................... 29
Supply voltage .............................. 30
Power consumption ........................... 31
Current consumption .......................... 31
Power supply failure .......................... 31
Electrical connection .......................... 32
Potential equalization ......................... 41
terminals .................................. 43
Cable entries ............................... 43
Cable specification ............................ 43
Performance characteristics .................. 45
Reference operating conditions ................... 45
Maximum measured error ....................... 45
Repeatability ............................... 46
Influence of ambient temperature ................. 46
Installation ............................... 46
Mounting location ............................ 46
Orientation ................................ 48
Inlet and outlet runs .......................... 48
Adapters .................................. 49
Length of connecting cable ...................... 49
Mounting the transmitter housing ................. 51
Special mounting instructions .................... 51
Environment .............................. 52
Ambient temperature range ..................... 52
Storage temperature .......................... 53
Degree of protection .......................... 53
Vibration resistance ........................... 53
Shock resistance ............................. 53
Shock resistance ............................. 53
Mechanical load ............................. 53
Electromagnetic compatibility (EMC) ............... 53
Process .................................. 53
Medium temperature range ...................... 53
Conductivity ................................ 54
Pressure-temperature ratings .................... 54
Pressure tightness ............................ 56
Flow limit ................................. 56
Pressure loss ............................... 57
System pressure ............................. 57
Vibrations ................................. 58
Mechanical construction .................... 58
Dimensions in SI units ......................... 58
Dimensions in US units ......................... 74
Weight ................................... 86
Measuring tube specification ..................... 90
Materials .................................. 91
Fitted electrodes ............................. 94
Process connections ........................... 94
Surface roughness ............................ 94
Operability ............................... 94
Operating concept ............................ 94
Languages ................................. 95
Local operation .............................. 95
Remote operation ............................ 95
Service interface ............................ 101
Network integration .......................... 102
Supported operating tools ...................... 103
HistoROM data management .................... 104
Certificates and approvals .................. 106
CE mark .................................. 106
C-Tick symbol .............................. 106
Ex approval ............................... 106
Pharmaceutical compatibility .................... 107
Drinking water approval ....................... 107
HART certification ........................... 107
FOUNDATION Fieldbus certification ............... 107
Certification PROFIBUS ........................ 108
EtherNet/IP certification ....................... 108
Certification PROFINET ........................ 108
Radio approval ............................. 108
Other standards and guidelines .................. 108
Ordering information ...................... 109
Application packages ...................... 109
Diagnostics functions ......................... 109
Heartbeat Technology ........................ 109
Cleaning ................................. 110
OPC-UA server ............................. 110