TH51, TH52, TH56
Endress+Hauser 3
Measurement range Measuring range by type and size
!Note!
These values are valid for single and duplex thermocouples. The temperature limits given are intended only as
a guide to the user and should not be taken as absolute values or as guarantees of satisfactory life or
performance. These types and sizes are sometimes used at temperatures above the given limits, but usually at
the expense of stability or life or both. In other instances, it may be necessary to reduce the above limits in
order to achieve adequate service.
!Note!
Duplex versions (2 elements) of Type N with 1/16", 3/16" and 3/8" sheath diameter are not available.
Thermocouples with 316 SS sheath are rated for a maximum temperature of 1700 °F (927 °C).
Electronics
Family of temperature trans-
mitters
Thermocouple assemblies with iTEMP®transmitters are an installation ready solution to improve the
functionality of temperature measurement by increasing accuracy and reliability when compared to direct
wired sensors. Overall installation costs are lower than with direct wired sensors, since an inexpensive pair of
signal (4 to 20 mA) wires can be run over long distances.
PC programmable device TMT
181
PC programmable devices offer you extreme flexibility and help control costs with the ability to stock one
device and program it for your needs. Regardless of your choice of output, all iTEMP®transmitters can be
configured quickly and easily with a PC. To help you with this task, Endress+Hauser offers free software
ReadWin®2000 which can be downloaded from our website. Go to www.readwin2000.com to download
ReadWin®2000 today.
HART®device TMT 182 HART®communication is all about easy, reliable data access and getting better information more
inexpensively. iTEMP®transmitters integrate seamlessly into your existing control system and provide painless
access to preventative diagnostic information.
Configuration with a DXR 275 or 375 hand-held or a PC with configuration program (Commuwin II,
ReadWin®2000) or configure with AMS or PDM.
Field transmitter TMT 162 Field transmitter with HART®communication and blue backlit display. Can be read easily from a distance, in
sunlight and at night. Large measurement value, bargraph and fault indication displayed. Benefits are: dual
sensor input, highest reliability in harsh industrial environments, mathematic functions, thermometer drift
monitoring and sensor back-up functionality, corrosion detection.
Upper Temperature Limits for Various Sheath Diameters °F (°C)
Nominal Diameter Thermocouple Type
Sheath OD Element wire
Dia. (in)
Element wire
Gauge
TJEKN
∅1/16" 0.010 30 500 °F (260 °C) 825 °F (440 °C) 950 °F (510 °C) 1690 °F (920 °C)
∅1/8" 0.020 24 600 °F (315 °C) 970 °F (520 °C) 1200 °F (650 °C) 1960 °F (1070 °C)
∅3/16" 0.029 21
700 °F (370 °C)
1150 °F (620 °C) 1350 °F (730 °C)
2100 °F (1150 °C)∅¼" 0.039 19 1330 °F (720 °C) 1510 °F (820 °C)
∅3/8" 0.060 15
Maximum Element
Temperature Range Limits
-454 to 752 °F
(-270 to +400 °C)
-346 to 2192 °F
(-210 to +1200 °C)
-454 to 1832 °F
(-270 to +1000 °C)
-454 to 2500 °F
(-270 to +1372 °C)
-454 to 2372 °F
(-270 to +1300 °C)