Entrotec PRO-DC1 Assembly instructions

Legal
2
Legal and Copyright Notice
Entrotec regularly develop and enhance product lines, these changes will be included in the latest
documentation. Whilst every effort has been made to ensure the accuracy of the information
supplied herein, Entrotec is not responsible for any errors or omissions. Many of the images
shown are for illustration purpose only. The actual product may vary due to product enhancement
or custom configurations. The materials contained in this document are protected and may be
subject to intellectual property rights.
Copyright 2021 Entrotec Limited. All rights reserved.
Installation Specification
It is the responsibility of the installer to follow Entrotec’s installation and cable specification as well
as ALL relevant wiring regulations. Failure to comply with Entrotec’s installation and cable
specification may result in erratic operation of equipment and could invalidate any warranty.
Installations must comply with the following applicable standards:
•BS 7671: Requirements for electrical installations. IET Wiring Regulations 18th Edition.
•The Electricity at Work Regulations 1989
•ANSI/TIA-568.0-D: Generic Telecommunications Cabling for Customer Premises.
•ANSI/TIA-568.1-D: Commercial Building Telecommunications Cabling Standard.
IET Wiring Regulations 18th Edition: Regulation 444 (MEASURES AGAINST ELECTROMAGNETIC
DISTURBANCES) imposes requirements for segregation of circuits.
IET Wiring Regulations 18th Edition: Regulation 528 (PROXIMITY TO WIRING SYSTEMS TO OTHER
SERVICES) imposes requirements for segregation of door entry / access control circuits (Band I),
230VAC mains circuits (Band II) and other higher voltage circuits.
IET Wiring Regulations 18th Edition: Regulations 541 and 542 impose requirements for earthing
and bonding conductors. Ensure ALL metalwork is bonded to the buildings earth, this includes call
panels, exit switches, cabinets and metal conduit. Ring terminals and earth points are provided on
call panels and cabinets to terminate earth cables, ensure these connections are made.
WARNING - ISOLATION OF ELECTRICAL EQUIPMENT
In compliance with The Electricity at Work Regulations 1989, electrical equipment should be
made dead to prevent danger while work is carried out on or near that equipment. No person
shall be engaged in any work activity on or so near any live conductor.
Warranty and Support
Entrotec systems are renowned for their reliability and have a 2-year warranty on all Entrotec
manufactured products as standard. This warranty does not cover water damage, vandalism,
mains electrical faults, lightning strikes, damage caused by miswiring or cable faults.
Entrotec offer complimentary training courses and telephone support:
01506 886 235 - 8:30am to 5pm Mon-Thurs and 8:30am to 4pm Friday.
technicalsupport@entrotec.co.uk

Contents
3
Contents
1Cable Specification ............................................................................................................4
Typical Configuration ......................................................................................................4
2Overview...........................................................................................................................5
3Power Supply ....................................................................................................................6
Mains Supply Connections..............................................................................................6
4Secure Lock Relay ..............................................................................................................7
Input + Exit Switch Connections .....................................................................................7
Fail Open Lock Connection .............................................................................................7
Fail Closed Lock Connection ...........................................................................................7
Lock Suppression ............................................................................................................7
5Call Panel Splitter ..............................................................................................................8
6Call Panel Connections.......................................................................................................8
7Pairing Secure Lock Relay with Call Panel ...........................................................................9
Confirm Door No. of Call Panel.......................................................................................9
Secure Lock Relay RS485 Address...................................................................................9
8Device List.......................................................................................................................10

Cable Specification
4
1Cable Specification
The cabling system is based on Unshielded Twisted Pair Category 5e (Cat5e) or Category 6 (Cat6).
The cable must be annealed pure copper, meeting or exceeding the requirements defined in the
standard ANSI/TIA 568 C.2.
Failure to comply with this cable specification may result in erratic operation of equipment.
The specification below shows the minimum cable requirements, allow for extra cabling if
redundancy is required.
Connection
Cable
A
Door controller to each call
panel:
2x Cat5e or Cat6.
B
Lock Relay to locks:
2x 1.5mm² multi-stranded flex or singles (route through
any exit/fire switch or break glass for fail safe operation).
C
Lock Relay to exit switch:
1 Pair UTP (2 cores), Cat5e or Cat6.
D
Lock Relay to fire switch:
1 Pair UTP (2 cores), Cat5e or Cat6.
Typical Configuration
FIGURE 1-1
NOTE
For setup of the Call Panel refer to the PRO-DP* Installation Guide.

Power Supply
6
3Power Supply
FIGURE 3-1
Mains Supply Connections
FIGURE 3-2
WARNING
Isolate mains supply before connecting.
Fused Terminal Block
Earth Point
Pre-Wired 12V to Internal Devices
Backup Battery Connections for
Sealed Lead Acid Battery
Output Voltage Adjustment
SYSTEM VOLTAGE 13.8VDC
Always test the output voltage.
Only adjust if required.
Fuse Holder
Mains Supply Cable from
Fused Spur
1.5mm² Twin + Earth
LIVE - BROWN
NEUTRAL - BLUE
EARTH - GREEN/YELLOW
Sheath
A
B
C
D
E
A
B
L
N
E
B
B
L
N
E
E
A
C
D
A

Secure Lock Relay
7
4Secure Lock Relay
FIGURE 4
PL1 - Input Connections: Trigger
Input
FS1 - Lock Supply Fuse
(2 Amp Time Delay)
PL2 - Output Connections: Lock
Supply and Relay Outputs
VR1 – Not Used
SW1 - RS485 Address
Input + Exit Switch Connections
FIGURE 4-1
For double pole push to exit / fire switches
with fail open locks, see section 4.2.
Fail Open Lock Connection
Connection for fail open locks (power to
hold), e.g. magnetic locks.
FIGURE 4-2
Fail Closed Lock Connection
Connection for fail closed locks (power to
release), e.g. electric strike.
FIGURE 4-3
Lock Suppression
+
_
Lock
Secure
Lock
Relay
FIGURE 4-4 - 1N4007 DIODE FITTED AT LOCK
Entrotec recommend locks with built in
suppression. If such a lock is not being used
it is ESSENTIAL to fit suitable suppression, as
close to the lock as possible. This prevents
back EMF and spikes from damaging
equipment and causing erratic operation.
WARNING
Failure to fit adequate suppression may
invalidate any warranty.
SUITABLE SUPPRESSION
Entrotec supply 1N4007 diodes.
A
B
C
D
E
D
A
C
B
E

Call Panel Splitter
8
5Call Panel Splitter
FIGURE 5-1
6Call Panel Connections
FIGURE 6-1
Connection
Cable Type
Detail
RS485 from Call Panel Splitter
1x Cat5e or Cat6
1 Pair UTP - RS485A + RS485B
12VDC from Call Panel
Splitter
1 Pair UTP - 12v (White)
2 Pair UTP - 0v (Black)
Ethernet to Network Switch
1x Cat5e or Cat6
RJ45 - T568B
FIGURE 6-2 - EIA/TIA-568B COLOUR CODE
12VDC Connections to Call Panel
12v, 0v
RS485 Data to Call Panel
FS1-FS4 - Call Panel Supply Fuses
(1.25 Amp Fast Acting)
PL5 - Not Used
PL1-PL4 - Call Panel Connection
Plugs
A
B
C
D
E
A
B
C
Up to 90M
A
B
C
C
D
E
A
B

Pairing Secure Lock Relay with Call Panel
9
7Pairing Secure Lock Relay with Call Panel
Confirm Door No. of Call Panel
i. Connect a laptop or PC to the same network as the Call Panel.
ii. Use a web browser and enter the IP address of the Call Panel in to the address bar.
iii. Login to the call panel using the username admin and the device admin password.
iv. Navigate to Local Settings > Basic.
v. Check the Door No. - each Call Panel on a block should have a unique number.
FIGURE 7-1
Secure Lock Relay RS485 Address
•Each Secure Lock Relay must have the address corresponding to the last 2 digits within the Door
No. of the associated Call Panel.
oE.g. Door No. 8001 = RS485 address 1. Door No. 8015 = RS485 address 15.
•SW1 Switches 1-6 set the binary address (0-63).
Switch
1
2
3
4
5
6
Binary Value
1
2
4
8
16
32
Address 0
0
0
0
0
0
0
Address 1
1
0
0
0
0
0
Address 3
1
1
0
0
0
0
Address 7
1
1
1
0
0
0
Address 15
1
1
1
1
0
0
Address 31
1
1
1
1
1
0
Address 63
1
1
1
1
1
1
FIGURE 7-2 - BINARY ADDRESS TABLE
ON = 1
OFF = 0

Device List
10
8Device List
IP Address
Block ID
SIP ID
Type
Description
192.168.1.111
1
8001
Call Panel
Ashwood Court, Front Door

Notes
11
This manual suits for next models
1
Table of contents
Other Entrotec Intercom System manuals
Popular Intercom System manuals by other brands

Elvox
Elvox 6600 Series Installer's guide

Cusam
Cusam CS-200BV-1 user manual

Telegärtner
Telegärtner DoorLine Pro EXCLUSIVE Series Operating and assembly instructions

Farfisa
Farfisa Alba Series manual

Vimar
Vimar ELVOX Pixel Up Series Installation and wiring manual

Fermax
Fermax 1-2L VDS KIT VIDEO OUTDOOR PANEL installation instructions