Entrotec ELITE User manual

ELITE
INSTALLATION
MANUAL
REV 3
USING ENT07101 Rev 3 VER0113

PREMAN0113/VAT/1
Recommended Installation Procedures
for Entrotec Equipment.
The recommendations give below assume the use of CW1308 type cable and are made in conjunction
with reference to IEE Wiring Regulations 17th Edition 528-01 ‘Proximity to electrical services’ and
BS EN 61000-6-3:2007 & BS EN 50133-1.
Door entry & access control equipment are in ‘Band 1’ classification.
230v mains cables are in the ‘Band 2’ classification.
Other cable types can be used but the guidelines given below may or may not be relevant and other
installation procedures may need to be adapted.
All unprotected cable runs should be kept away from mains cables as the radiation from these cables
may cause the system to be erratic in operation.
In a building where the only way to wire is via an electrical intake, riser cupboard or lift shaft then metallic
trunking or conduit should be used unless there is sufficient room within the cupboards to distance
the door entry cables from the mains cables.
Mains cables should not be run in the same trunking/conduit as the door entry cables
(although segregated metallic compartment trunking is acceptable).
We recommend that where the cabling is not protected in a metallic containment system that a distance
of 1 Metre should be adopted unless other protective measures have been taken conforming to the
relevant industry regulations.
If unprotected cables are to run across mains cables then this should be at 90 degrees.
In accordance with IEE Wiring Regulations (17th Edition) please ensure that all metalwork is bonded to the
buildings earth, this includes the main control panel, all conduit (if metallic) and most importantly THE
EXTERNAL CALL PANELS, READERS & FIRE SWITCHES. A ring connector is provided in the external panels
for termination of the earth cable but this bonding is often ignored, please ensure that this connection is made.
If you have any queries about a particular site or are in need of technical assistance please
phone, fax or email Entrotec for technical help :-
Tel: 08448586370
Fax: 01506 886233
Email:
Vaughn Turner
System Engineering Manager
Issue 6. 14/01/2013
Warning!!! Rogue cable is prevalent. Please ensure cables are pure copper and not copper clad imitations
as their high resistance will cause system malfunction. These cables may have CCS, CCA, CCAM in their
description/part number and are definitely to be avoided as are unmarked outer sheaths. These cables are
available in CW1308, RG59, CAT5/6 and mains supply formats. Entrotec will not accept any responsibility
for systems wired with incorrect cable (i.e. not to specification).
Tests. To test for CCS (copper clad steel) use a magnet, if it attracts Do Not Use. To test for CCA (copper
clad aluminium) heat core with a lighter, if aluminium melts (as its melting point is much lower than copper)
Do Not Use. CCAM (copper clad magnesium) is not widely available at present but will burn using the heat
test.
PREMAN0113/VAT/2
Contents
System Overview and Specification. ...................................1
Cabling Requirements. ........................................................2
Overall Schematic. ..............................................................3
Typical Controller Layout. ....................................................4
Typical Installation Layout. ..................................................5
Handset Connections. .........................................................6
Video Schematic. ................................................................7
Preset Adjustments. ............................................................7
Programming the ‘On Board’ Service/Trades Time Clock. ..8
Handset Auxiliary Equipment Connections. ....................... 9
FS4/FS5/PTE/EPTE Wiring. .............................................. 10
Typical Wiring Schematics. ............................................11-12

PREMAN0113/VAT/1
Recommended Installation Procedures
for Entrotec Equipment.
The recommendations give below assume the use of CW1308 type cable and are made in conjunction
with reference to IEE Wiring Regulations 17th Edition 528-01 ‘Proximity to electrical services’ and
BS EN 61000-6-3:2007 & BS EN 50133-1.
Door entry & access control equipment are in ‘Band 1’ classification.
230v mains cables are in the ‘Band 2’ classification.
Other cable types can be used but the guidelines given below may or may not be relevant and other
installation procedures may need to be adapted.
All unprotected cable runs should be kept away from mains cables as the radiation from these cables
may cause the system to be erratic in operation.
In a building where the only way to wire is via an electrical intake, riser cupboard or lift shaft then metallic
trunking or conduit should be used unless there is sufficient room within the cupboards to distance
the door entry cables from the mains cables.
Mains cables should not be run in the same trunking/conduit as the door entry cables
(although segregated metallic compartment trunking is acceptable).
We recommend that where the cabling is not protected in a metallic containment system that a distance
of 1 Metre should be adopted unless other protective measures have been taken conforming to the
relevant industry regulations.
If unprotected cables are to run across mains cables then this should be at 90 degrees.
In accordance with IEE Wiring Regulations (17th Edition) please ensure that all metalwork is bonded to the
buildings earth, this includes the main control panel, all conduit (if metallic) and most importantly THE
EXTERNAL CALL PANELS, READERS & FIRE SWITCHES. A ring connector is provided in the external panels
for termination of the earth cable but this bonding is often ignored, please ensure that this connection is made.
If you have any queries about a particular site or are in need of technical assistance please
phone, fax or email Entrotec for technical help :-
Tel: 08448586370
Fax: 01506 886233
Email:
Vaughn Turner
System Engineering Manager
Issue 6. 14/01/2013
Warning!!! Rogue cable is prevalent. Please ensure cables are pure copper and not copper clad imitations
as their high resistance will cause system malfunction. These cables may have CCS, CCA, CCAM in their
description/part number and are definitely to be avoided as are unmarked outer sheaths. These cables are
available in CW1308, RG59, CAT5/6 and mains supply formats. Entrotec will not accept any responsibility
for systems wired with incorrect cable (i.e. not to specification).
Tests. To test for CCS (copper clad steel) use a magnet, if it attracts Do Not Use. To test for CCA (copper
clad aluminium) heat core with a lighter, if aluminium melts (as its melting point is much lower than copper)
Do Not Use. CCAM (copper clad magnesium) is not widely available at present but will burn using the heat
test.
PREMAN0113/VAT/2
Contents
System Overview and Specification. ...................................1
Cabling Requirements. ........................................................2
Overall Schematic. ..............................................................3
Typical Controller Layout. ....................................................4
Typical Installation Layout. ..................................................5
Handset Connections. .........................................................6
Video Schematic. ................................................................7
Preset Adjustments. ............................................................7
Programming the ‘On Board’ Service/Trades Time Clock. ..8
Handset Auxiliary Equipment Connections. ....................... 9
FS4/FS5/PTE/EPTE Wiring. .............................................. 10
Typical Wiring Schematics. ............................................11-12

Cabling Requirements Page 2
EliteMAN0113/ 2 of 12
1). Between front panel(s)
and main control unit.
2). Between lock releases
and main control unit.
3). Between handsets and
main control unit.
4). Between ancillary
equipment and main
control unit if fitted.
5). Between readers and
access control unit if fitted.
6). Between camera and
main control unit if fitted.
7). Between handsets and
flashing beacons and/or
extension sounders.
8). Between MLR display(s)
and main control unit.
9). Between handsets and
extension handsets
CW1308 - 1 core per handset attached, 2 cores for common +
service (trades) and 4 cores for speech. If DDA display fitted
(MLR PCB), a further 5 cores minimum are required. Note: an
earth wire is required between the front panel and systems
bonded earth. If ENT11130A fitted then 1 core per handset + 2
core for common & Trades + 1 6 pair for LCD/SP/Amp
connections.
2 Cores 1.5mm² Minimum (Running via any Push To Exit and Fire
Switches). 2 pair CW1308 for door monitoring and anti-tailgating.
CW1308 - 4 pair minimum or 6 pair minimum if using Entroview
series video handsets.
CW1308 - 2 cores for each of the following:- Push to exit, Fire
switch, Door open buzzer. Door contacts require 3 cores if using
the Anti-tailgating circuit. Note: Fail safe lock release cables
should be run via fire switch and push to exit NC contacts.
CW1308 - 6 cores minimum (run separately from other multi -
cores).
1 x RG59U + 1 pair CW1308 for Camera power.
4 cores of CW1308.
CW1308 - 5 cores minimum.
CW1308 - 4 pair minimum.
Ancillary Equipment
System overview and specification
The RDC Elite system Using ENT07101 Rev 3
The ENT07101 Rev 3 PCB has the following features :-
1). Full isolation of handsets. If a user ‘damages’ or shorts the cables to the handset then only
this handset will be affected, all other handsets will work independently.
2). Full fuse isolation of all power supply lines.
3). Call monitoring. Green LED’s on the control PCB illuminate to show a call in progress and
handset being called.
4). Fuse ‘blown’ indicator LED’s. Red LED’s illuminate to show that a handset fuse has blown.
5). Switch Mode power supply. Up to 3.6 amps continuous at 13.8 volts. (Can be increased to suit
requirements).
6). Battery backup. When required via Switch Mode power supply set at 13.8 volts.
7). Up to 16 handsets. Up to 8 handsets on main PCB and a further 8 handset ports by using an
8 way marshalling PCB.
8). Dual entrance. Can be supplied as a 8 or 16 way dual entrance system (additional marshalling
PCB required if more than 8 handsets are required).
9). Video system. The system can be upgraded to a video system on a ‘mix & match’ basis
using standard Entroview twisted pair series video handsets.
Requires minimum of 12 cores (6 pair CW1308) to handset and the inclusion of video
camera(s). 1 additional pair and a video coax is required between each camera
panel and the main control unit.
10). Adjustable call period. Length of time a handset is ‘live’ for, once a call is made to it. 1 to 60
seconds adjustable via preset.
11). Adjustable call tone period. Length of time a handset ‘rings’ for, once called. 1 to 60
seconds adjustable via preset.
12). Adjustable speech period. Length of time a caller can speak for, once a handset has been
lifted (this time period is terminated on replacement of the handset),
adjustable via preset. 10 to 120 seconds.
14). Adjustable lock release period. Length of time a door is released for, once opened,
adjustable via preset. 1 to 60 seconds.
15). Anti- tail gating. Shortens door release time to 1 second after door is open (requires n/c
door contact when the door is in the closed position).
16). Call tone reassurance. Call tone reassurance at front panel (level adjustable via preset).
17). Onboard Summer/Winter time clock. Inbuilt Trades clock that automatically adjusts to GMT
summer / winter time periods. By removal of link PL14 an external time
clock can be used by connecting it’s contacts to PL23 0v and ETC.
Page 1
EliteMAN0113/ 1 of 12

Cabling Requirements Page 2
EliteMAN0113/ 2 of 12
1). Between front panel(s)
and main control unit.
2). Between lock releases
and main control unit.
3). Between handsets and
main control unit.
4). Between ancillary
equipment and main
control unit if fitted.
5). Between readers and
access control unit if fitted.
6). Between camera and
main control unit if fitted.
7). Between handsets and
flashing beacons and/or
extension sounders.
8). Between MLR display(s)
and main control unit.
9). Between handsets and
extension handsets
CW1308 - 1 core per handset attached, 2 cores for common +
service (trades) and 4 cores for speech. If DDA display fitted
(MLR PCB), a further 5 cores minimum are required. Note: an
earth wire is required between the front panel and systems
bonded earth. If ENT11130A fitted then 1 core per handset + 2
core for common & Trades + 1 6 pair for LCD/SP/Amp
connections.
2 Cores 1.5mm² Minimum (Running via any Push To Exit and Fire
Switches). 2 pair CW1308 for door monitoring and anti-tailgating.
CW1308 - 4 pair minimum or 6 pair minimum if using Entroview
series video handsets.
CW1308 - 2 cores for each of the following:- Push to exit, Fire
switch, Door open buzzer. Door contacts require 3 cores if using
the Anti-tailgating circuit. Note: Fail safe lock release cables
should be run via fire switch and push to exit NC contacts.
CW1308 - 6 cores minimum (run separately from other multi -
cores).
1 x RG59U + 1 pair CW1308 for Camera power.
4 cores of CW1308.
CW1308 - 5 cores minimum.
CW1308 - 4 pair minimum.
Ancillary Equipment
System overview and specification
The RDC Elite system Using ENT07101 Rev 3
The ENT07101 Rev 3 PCB has the following features :-
1). Full isolation of handsets. If a user ‘damages’ or shorts the cables to the handset then only
this handset will be affected, all other handsets will work independently.
2). Full fuse isolation of all power supply lines.
3). Call monitoring. Green LED’s on the control PCB illuminate to show a call in progress and
handset being called.
4). Fuse ‘blown’ indicator LED’s. Red LED’s illuminate to show that a handset fuse has blown.
5). Switch Mode power supply. Up to 3.6 amps continuous at 13.8 volts. (Can be increased to suit
requirements).
6). Battery backup. When required via Switch Mode power supply set at 13.8 volts.
7). Up to 16 handsets. Up to 8 handsets on main PCB and a further 8 handset ports by using an
8 way marshalling PCB.
8). Dual entrance. Can be supplied as a 8 or 16 way dual entrance system (additional marshalling
PCB required if more than 8 handsets are required).
9). Video system. The system can be upgraded to a video system on a ‘mix & match’ basis
using standard Entroview twisted pair series video handsets.
Requires minimum of 12 cores (6 pair CW1308) to handset and the inclusion of video
camera(s). 1 additional pair and a video coax is required between each camera
panel and the main control unit.
10). Adjustable call period. Length of time a handset is ‘live’ for, once a call is made to it. 1 to 60
seconds adjustable via preset.
11). Adjustable call tone period. Length of time a handset ‘rings’ for, once called. 1 to 60
seconds adjustable via preset.
12). Adjustable speech period. Length of time a caller can speak for, once a handset has been
lifted (this time period is terminated on replacement of the handset),
adjustable via preset. 10 to 120 seconds.
14). Adjustable lock release period. Length of time a door is released for, once opened,
adjustable via preset. 1 to 60 seconds.
15). Anti- tail gating. Shortens door release time to 1 second after door is open (requires n/c
door contact when the door is in the closed position).
16). Call tone reassurance. Call tone reassurance at front panel (level adjustable via preset).
17). Onboard Summer/Winter time clock. Inbuilt Trades clock that automatically adjusts to GMT
summer / winter time periods. By removal of link PL14 an external time
clock can be used by connecting it’s contacts to PL23 0v and ETC.
Page 1
EliteMAN0113/ 1 of 12

Overall Schematic (Using ENT07101 Rev 3)
Page 3
16 x 2 LCD Module
for Trade Clock Setting
Prog Right UP
SN SB DO CA
Door ‘B’
Connections
Door ‘A’ Connections
RG59 to
Camera
RG59 to
Camera
2 AMP
Delay
500mA
Fast Blow
Handset Fuses 500mA Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
2 AMP
Delay
3.15 AMP
Delay
12V
0V
PL1
PL2
PL3
PL4
PL5
PL6
PL8 PL12 PL21 PL25
PL29
PL30
PL31
PL32
PL28
PL24
PL22
PL20
PL18
PL16
PL15
PL13PL11PL10
PL17
V+
V-
0v
ETC
PL19 PL23
Speech
Time
Callup
Time
Call Tone
Time
Reassurance
Volume
Door A
Lock Timer
Door B
Lock Timer
Common Bus
PL7
PL14
DR
VT
0V
BZ
S2
S1
DS
V-
V+
DR
VT
0V
BZ
S2
S1
DS
FS1 FS11
Re-Assurance LED’s
Showing system status
Video Adj.
Trade Clock Link
Remove if using
external timer
PL7 & 27 =
Anti-tailgating
Link. Remove
to use ATG
connection.
PL7 & 27 =
Anti-tailgating
Link. Remove
to use ATG
connection.
EliteMAN0113/ 3 of 12
Terminal Identifier:-
PL1, 2, 29 & 30 - Button returns/call lines 1 to 16 for doors A & B. Sit at 5 volts DC and go to 0v when button pressed.
PL3 & 31 (S) - Service/Trades (S) button returns for doors A & B. Sit at 5 volts DC and go to 0v when button pressed.
PL3 & 31 (C) - Button common sits at 0v.
PL4 & 32 - Speaker amp connections for doors A & B. +6 = 6 volts DC, 0v = 0v. S1 = door panel microphone, S2 = door panel speaker.
PL6 & 28 (12v) - 12 volts DC supply to locks fused by FS1 & FS11. Use 1.5mm flex
PL6 & 28 (NC) - Normally Closed switched 0v for fail open releases. Use 1.5mm flex
PL6 & 28 (NO) - Normally Open switched 0v for fail locked releases. Use 1.5mm flex
PL6 & 28 (C, NC & NO) - volt free spare contacts to trigger automatic doors etc.
PL5 & 33 (C) - 0v common for external lock triggers.
PL5 & 33 (FS) - Non timed fire switch input (for timed input when using Drop key switches use PE). Sits at 5 volts and drops to 0v.
PL5 & 33 (PE) - Timed lock release trigger for push to exits, drop key fire switches and access controllers. Sits at 5 volts and drops to 0v.
PL5 & 33 (AT) - Anti tail gating. Requires normally open going closed door monitor contacts. Sits at 0v and goes to 5 volts when door opened.
If not used insert PL7 & 27.
PL14 - Service/Trades timeclock link. Remove if using external timeclock.
PL17 - 12 to 14 volt DC power supply input.
PL19 - Twisted pair video output to expansion PCB’s etc.
PL23 - External service/trades time clock input. Note: remove PL14 to disable internal time clock.
PL24 - Common bus to remote marshalling PCB’s. DR = Door Release, VT = 12 volt DC supply, 0v = 0v, BZ = buzz tone, S2 = mic input
from handset, S1 = speaker input to handset, DS = Door Status for door open LED on handset.
PL10, 11, 13, 15, 16, 18, 19, 20 & 22 - Phone ports for first 8 handsets. See Page 6 for handset connections.
PL8 & 25 - Video inputs from cameras. Use RG59 screened cable.
PL12 & 21 - MLR connections to door panel MLR PCB’s. SN = Speak Now, SB = System Busy, DO = Door Open & CA = Call Accept
NOTE:- Cables colour coded for suggested installation wiring. Note all cables CW1308 unless stated otherwise.
2
2
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
S
C
+6V
0V
S1
S2
12V
NC
NO
C
NC
NO
C
FS
PE
AT
PL33
PL27
SN SB DO CA SN SB DO CA
9
10
11
12
13
14
15
16
S
C
+6V
0V
S1
S2
12V
NC
NO
C
NC
NO
C
FS
PE
AT
-
+
Battery
1
2
3
4
5
6
7
8
DR
VT
0V
BZ
S2
S1
DS
V-
V+
CB
X
CALL CALL CALL CALL CALL CALL CALL CALL
FUSED FUSED FUSED FUSED FUSED FUSED FUSED FUSED
12V0V DS S2S1 BZDR V- V+ Phone 9 Phone 10 Phone 11 Phone 12 Phone 13 Phone 14 Phone 15 Phone 16
No
Connections
Required as
Ribbon Cable
Connects
No Connections Required
as Ribbon Cable Connects
Handset Fuses 500mA Fast Blow
Spare
DC output
ON
MCB
240~ Input
Page 4
Typical Controller Layout (Using ENT07101 Rev 3)
16 x 2 LCD Module
for Trade Clock Setting
Prog Right UP
SN SB DO CA SN SB DO CASN SB DO CA SN SB DO CA
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
S
C
+6V
0V
S1
S2
12V
NC
NO
C
NC
NO
C
FS
PE
AT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
S
C
+6V
0V
S1
S2
12V
NC
NO
C
NC
NO
C
FS
PE
AT
2 AMP
Delay
500mA
Fast Blow
Handset Fuses 500mA Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
2 AMP
Delay
3.15 AMP
Delay 12V
0V
PL1
PL2
PL3
PL4
PL5
PL6
PL8 PL12 PL21 PL25
PL29
PL30
PL31
PL32
PL28
PL33
PL24
PL22
PL20
PL18
PL16
PL15
PL13PL11PL10
PL17
V+
V-
0v
ETC
PL19 PL23
Speech
Time
Callup
Time
Call Tone
Time
Reassurance
Volume
Door A
Lock Timer
Door B
Lock Timer
Common Bus
PL27PL7
PL14
DR
VT
0V
BZ
S2
S1
DS
V-
V+
DR
VT
0V
BZ
S2
S1
DS
FS1 FS11
Re-Assurance LED’s
Showing system status
Video Adj.
Trade Clock Link
Remove if using
external timer
EliteMAN0113/ 4 of 12
PSU60W Shown. Power supply may vary. 60W Power supplies
Post January 2011 have fixed 13.8v output and no spare
output. PSU Chassis is now Earthed.
Example of typical Elite controller layout. Parts and
models may vary.
1
2
3
4
5
6
7
8
WE/BE
BE/WE
WE/OE
OE/WE
WE/GN
GN/WE
WE/BN
BN/WE
WE/GY
GY/WE
RD/BE
BE/RD
RD/OE
OE/RD
RD/GN
GN/RD
RD/BN
BN/RD
NC
OE/WE+WE/GN+WE/BN
BN
BE
GN/WE
BN/WE
WE/BE+BE/WE+WE/OE
1 Amp
Fit In-Line
Fuse if
SBD
WE/GY
GY/WE
RD/BE
BE/RD
2
1.5mm Flex
WE/GY
GY/WE
RD/BE
BE/RD
SN SB DO CA
WE/BE
BE/WE
WE/OE
WE/BE
BE/WE
WE/OE
OE/WE
WE/GN
GN/WE
WE/BN
BN/WE
WE/GY
GY/WE
RD/BE
BE/RD
RD/OE
OE/RD
RD/GN
GN/RD
RD/BN
BN/RD
NC
GN/WE
BN/WE
OE/WE+WE/GN+WE/BN
WE/BE+BE/WE+WE/OE
Fit In-Line
Fuse if
SBD
BN
BE

Overall Schematic (Using ENT07101 Rev 3)
Page 3
16 x 2 LCD Module
for Trade Clock Setting
Prog Right UP
SN SB DO CA
Door ‘B’
Connections
Door ‘A’ Connections
RG59 to
Camera
RG59 to
Camera
2 AMP
Delay
500mA
Fast Blow
Handset Fuses 500mA Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
2 AMP
Delay
3.15 AMP
Delay
12V
0V
PL1
PL2
PL3
PL4
PL5
PL6
PL8 PL12 PL21 PL25
PL29
PL30
PL31
PL32
PL28
PL24
PL22
PL20
PL18
PL16
PL15
PL13PL11PL10
PL17
V+
V-
0v
ETC
PL19 PL23
Speech
Time
Callup
Time
Call Tone
Time
Reassurance
Volume
Door A
Lock Timer
Door B
Lock Timer
Common Bus
PL7
PL14
DR
VT
0V
BZ
S2
S1
DS
V-
V+
DR
VT
0V
BZ
S2
S1
DS
FS1 FS11
Re-Assurance LED’s
Showing system status
Video Adj.
Trade Clock Link
Remove if using
external timer
PL7 & 27 =
Anti-tailgating
Link. Remove
to use ATG
connection.
PL7 & 27 =
Anti-tailgating
Link. Remove
to use ATG
connection.
EliteMAN0113/ 3 of 12
Terminal Identifier:-
PL1, 2, 29 & 30 - Button returns/call lines 1 to 16 for doors A & B. Sit at 5 volts DC and go to 0v when button pressed.
PL3 & 31 (S) - Service/Trades (S) button returns for doors A & B. Sit at 5 volts DC and go to 0v when button pressed.
PL3 & 31 (C) - Button common sits at 0v.
PL4 & 32 - Speaker amp connections for doors A & B. +6 = 6 volts DC, 0v = 0v. S1 = door panel microphone, S2 = door panel speaker.
PL6 & 28 (12v) - 12 volts DC supply to locks fused by FS1 & FS11. Use 1.5mm flex
PL6 & 28 (NC) - Normally Closed switched 0v for fail open releases. Use 1.5mm flex
PL6 & 28 (NO) - Normally Open switched 0v for fail locked releases. Use 1.5mm flex
PL6 & 28 (C, NC & NO) - volt free spare contacts to trigger automatic doors etc.
PL5 & 33 (C) - 0v common for external lock triggers.
PL5 & 33 (FS) - Non timed fire switch input (for timed input when using Drop key switches use PE). Sits at 5 volts and drops to 0v.
PL5 & 33 (PE) - Timed lock release trigger for push to exits, drop key fire switches and access controllers. Sits at 5 volts and drops to 0v.
PL5 & 33 (AT) - Anti tail gating. Requires normally open going closed door monitor contacts. Sits at 0v and goes to 5 volts when door opened.
If not used insert PL7 & 27.
PL14 - Service/Trades timeclock link. Remove if using external timeclock.
PL17 - 12 to 14 volt DC power supply input.
PL19 - Twisted pair video output to expansion PCB’s etc.
PL23 - External service/trades time clock input. Note: remove PL14 to disable internal time clock.
PL24 - Common bus to remote marshalling PCB’s. DR = Door Release, VT = 12 volt DC supply, 0v = 0v, BZ = buzz tone, S2 = mic input
from handset, S1 = speaker input to handset, DS = Door Status for door open LED on handset.
PL10, 11, 13, 15, 16, 18, 19, 20 & 22 - Phone ports for first 8 handsets. See Page 6 for handset connections.
PL8 & 25 - Video inputs from cameras. Use RG59 screened cable.
PL12 & 21 - MLR connections to door panel MLR PCB’s. SN = Speak Now, SB = System Busy, DO = Door Open & CA = Call Accept
NOTE:- Cables colour coded for suggested installation wiring. Note all cables CW1308 unless stated otherwise.
2
2
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
S
C
+6V
0V
S1
S2
12V
NC
NO
C
NC
NO
C
FS
PE
AT
PL33
PL27
SN SB DO CA SN SB DO CA
9
10
11
12
13
14
15
16
S
C
+6V
0V
S1
S2
12V
NC
NO
C
NC
NO
C
FS
PE
AT
-
+
Battery
1
2
3
4
5
6
7
8
DR
VT
0V
BZ
S2
S1
DS
V-
V+
CB
X
CALL CALL CALL CALL CALL CALL CALL CALL
FUSED FUSED FUSED FUSED FUSED FUSED FUSED FUSED
12V0V DS S2S1 BZDR V- V+ Phone 9 Phone 10 Phone 11 Phone 12 Phone 13 Phone 14 Phone 15 Phone 16
No
Connections
Required as
Ribbon Cable
Connects
No Connections Required
as Ribbon Cable Connects
Handset Fuses 500mA Fast Blow
Spare
DC output
ON
MCB
240~ Input
Page 4
Typical Controller Layout (Using ENT07101 Rev 3)
16 x 2 LCD Module
for Trade Clock Setting
Prog Right UP
SN SB DO CA SN SB DO CASN SB DO CA SN SB DO CA
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
S
C
+6V
0V
S1
S2
12V
NC
NO
C
NC
NO
C
FS
PE
AT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
S
C
+6V
0V
S1
S2
12V
NC
NO
C
NC
NO
C
FS
PE
AT
2 AMP
Delay
500mA
Fast Blow
Handset Fuses 500mA Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
2 AMP
Delay
3.15 AMP
Delay 12V
0V
PL1
PL2
PL3
PL4
PL5
PL6
PL8 PL12 PL21 PL25
PL29
PL30
PL31
PL32
PL28
PL33
PL24
PL22
PL20
PL18
PL16
PL15
PL13PL11PL10
PL17
V+
V-
0v
ETC
PL19 PL23
Speech
Time
Callup
Time
Call Tone
Time
Reassurance
Volume
Door A
Lock Timer
Door B
Lock Timer
Common Bus
PL27PL7
PL14
DR
VT
0V
BZ
S2
S1
DS
V-
V+
DR
VT
0V
BZ
S2
S1
DS
FS1 FS11
Re-Assurance LED’s
Showing system status
Video Adj.
Trade Clock Link
Remove if using
external timer
EliteMAN0113/ 4 of 12
PSU60W Shown. Power supply may vary. 60W Power supplies
Post January 2011 have fixed 13.8v output and no spare
output. PSU Chassis is now Earthed.
Example of typical Elite controller layout. Parts and
models may vary.
1
2
3
4
5
6
7
8
WE/BE
BE/WE
WE/OE
OE/WE
WE/GN
GN/WE
WE/BN
BN/WE
WE/GY
GY/WE
RD/BE
BE/RD
RD/OE
OE/RD
RD/GN
GN/RD
RD/BN
BN/RD
NC
OE/WE+WE/GN+WE/BN
BN
BE
GN/WE
BN/WE
WE/BE+BE/WE+WE/OE
1 Amp
Fit In-Line
Fuse if
SBD
WE/GY
GY/WE
RD/BE
BE/RD
2
1.5mm Flex
WE/GY
GY/WE
RD/BE
BE/RD
SN SB DO CA
WE/BE
BE/WE
WE/OE
WE/BE
BE/WE
WE/OE
OE/WE
WE/GN
GN/WE
WE/BN
BN/WE
WE/GY
GY/WE
RD/BE
BE/RD
RD/OE
OE/RD
RD/GN
GN/RD
RD/BN
BN/RD
NC
GN/WE
BN/WE
OE/WE+WE/GN+WE/BN
WE/BE+BE/WE+WE/OE
Fit In-Line
Fuse if
SBD
BN
BE

Typical Installation Layout Page 5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
S
C
+6V
0V
S1
S2
12V
NC
NO
C
NC
NO
C
FS
PE
AT
PL1
PL2
PL3
PL4
PL5
PL6
SN SB DO CA
PL12
P4 P3 P2 P1
Please Note:-
FS is a none timed
input and is suitable
for Latching Fire
switches such as the
MEM type lever fire
switch.
NO
NO
NCNC
Fire
Switch
Push to
Exit
Magnetic or Fail
Open Release
1N4000
Series
Diode
Fail Secure Lock
Connection
Spare
Contacts
NC
NO To PL24 DS on common bus terminal
PL24
Common Bus
DR
VT
0V
BZ
S2
S1
DS
Note:-
Magnetic lock door contacts
CAN NOT be used for ATG
function as these locks now
monitor power to the lock
and not door status
ENT11130A
Part Number:
ASS11130A1
Elite LCD
12v 0v S1 S2 SN SB DO CA
-
+
-
+
Speaker Microphone
TP1
5vA
TP2
12v
TP3
5vD
TP4
0v
Speaker
Volume
PR1
PR3
Microphone
Volume
LCD
Contrast
PR2
1 Amp
Fuse
PL2 PL1
FS1
PL3
See Note A
Note A: Please note if system
is to conform to Secured By
Design standards then a 1A
in-line fuse must be fitted here.
Lock & trigger wires must not
be routed via the door panel.
P8 P7 P6 P5
P12 P11 P10 P9
P16 P15 P14 P13
T
Proximity
Reader
Mic
WE/BE
BE/WE
WE/OE
OE/WE
WE/GN
GN/WE
WE/BN
BN/WE
WE/GY
GY/WE
RD/BE
BE/RD
RD/OE
OE/RD
RD/GN
GN/RD
BN/RD RD/BN
NC
2
1.5mm Flex
OE/WE+
WE/GN+
WE/BN
WE/BE+
BE/WE+
WE/OE
Connections as per
Manufacturers Inst.
GN/WE BN/WE
WE/BE
BE/WE
WE/OE
OE/WE
BN
BE
BE/RD
RD/BE
GY/WE
WE/GY
EliteMAN0113/ 5 of 12 EliteMAN0113/ 6 of 12
Page 6
Handset Connections
DR
VT
0V
BZ
S2
S1
DS
Do Not Wire To EX With Spare Core(s)
PL10
ED3+ ED4+,& RH3+
Wiring Schematic
White/Blue
Blue/White
White/Orange
Orange/White
White/Green
Green/White
White/Brown
1(DR)
2(VT)
3(0V)
4(BZ)
5(S2)
6(S1)
7(DS)
ON
PRIVACY
ON
PRIVACY
4 Pair CW1308 Colour Code
PL10
DR (Door Release)
VT (12v DC)
0V (0 Volts)
BZ (Buzz input)
S2 (Mic)
S1 (Speaker)
DS (Door Status)
V- (TP Video -)
V+ (TP Video +)
White/Blue + Blue/White
White/Orange + Orange/White
White/Green + White/Brown
White/Grey
Green/White
Brown/White
‘EX’ To Extension Sounders/
Flashing Beacons Only
6 Pair CW1308 Colour Code
Grey/White
Red/Blue
Blue/Red
Note:- Spare Blue / White shown in ‘DR’ may be
used to ‘Double-Up’ on VT or 0V if needed.
DR
VT
0V
BZ
S2
S1
DS
V-
V+
CB
X
EX
Entroview 300 / 400
Wiring Schematic
NOTE - The EX
connection is ONLY
to be used on
Entrotec Extension
sounders and
accessories. DO
NOT fit a wire into
EX for any other
purpose.
Any unused cores to be tied to
system 0v.
ONLY USE
CW1308 CABLE
PL10
Multiple ED3+ ED4+ & RH3+
Wiring Schematic (up to 3).
White/Blue
Blue/White
White/Orange
Orange/White
White/Green
Green/White
White/Brown
1(DR)
2(VT)
3(0V)
4(BZ)
5(S2)
6(S1)
7(DS)
ON
PRIVACY
ON
PRIVACY
4 Pair CW1308 Colour Code
1(DR)
2(VT)
3(0V)
4(BZ)
5(S2)
6(S1)
7(DS)
ON
PRIVACY
ON
PRIVACY
8(EX)
1(DR)
2(VT)
3(0V)
4(BZ)
5(S2)
6(S1)
7(DS)
8(V-)
9(V+)
1(DR)
2(VT)
3(0V)
4(BZ)
5(S2)
6(S1)
7(DS)
8(V-)
9(V+)
DR
VT
0V
BZ
S2
S1
DS
V-
V+
CB
X
EX
DR
VT
0V
BZ
S2
S1
DS
V-
V+
CB
X
EX
Spare port
supplies
12v & Video
1 port per
additional
handset reqd.
Handset port where call
is made to e.g. Phone 1
with 2 video handsets.
Mulitple Video
Handsets per call
(up to 3)
Separate Door Contacts
White/Blue + Blue/White
White/Orange + Orange/White
White/Green + White/Brown
White/Grey
Green/White
Brown/White
Grey/White
Blue/Red
Red/Blue
White/Blue + Blue/White
White/Orange + Orange/White
Blue/Red
Red/Blue
Orange/White

Typical Installation Layout Page 5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
S
C
+6V
0V
S1
S2
12V
NC
NO
C
NC
NO
C
FS
PE
AT
PL1
PL2
PL3
PL4
PL5
PL6
SN SB DO CA
PL12
P4 P3 P2 P1
Please Note:-
FS is a none timed
input and is suitable
for Latching Fire
switches such as the
MEM type lever fire
switch.
NO
NO
NCNC
Fire
Switch
Push to
Exit
Magnetic or Fail
Open Release
1N4000
Series
Diode
Fail Secure Lock
Connection
Spare
Contacts
NC
NO To PL24 DS on common bus terminal
PL24
Common Bus
DR
VT
0V
BZ
S2
S1
DS
Note:-
Magnetic lock door contacts
CAN NOT be used for ATG
function as these locks now
monitor power to the lock
and not door status
ENT11130A
Part Number:
ASS11130A1
Elite LCD
12v 0v S1 S2 SN SB DO CA
-
+
-
+
Speaker Microphone
TP1
5vA
TP2
12v
TP3
5vD
TP4
0v
Speaker
Volume
PR1
PR3
Microphone
Volume
LCD
Contrast
PR2
1 Amp
Fuse
PL2 PL1
FS1
PL3
See Note A
Note A: Please note if system
is to conform to Secured By
Design standards then a 1A
in-line fuse must be fitted here.
Lock & trigger wires must not
be routed via the door panel.
P8 P7 P6 P5
P12 P11 P10 P9
P16 P15 P14 P13
T
Proximity
Reader
Mic
WE/BE
BE/WE
WE/OE
OE/WE
WE/GN
GN/WE
WE/BN
BN/WE
WE/GY
GY/WE
RD/BE
BE/RD
RD/OE
OE/RD
RD/GN
GN/RD
BN/RD RD/BN
NC
2
1.5mm Flex
OE/WE+
WE/GN+
WE/BN
WE/BE+
BE/WE+
WE/OE
Connections as per
Manufacturers Inst.
GN/WE BN/WE
WE/BE
BE/WE
WE/OE
OE/WE
BN
BE
BE/RD
RD/BE
GY/WE
WE/GY
EliteMAN0113/ 5 of 12 EliteMAN0113/ 6 of 12
Page 6
Handset Connections
DR
VT
0V
BZ
S2
S1
DS
Do Not Wire To EX With Spare Core(s)
PL10
ED3+ ED4+,& RH3+
Wiring Schematic
White/Blue
Blue/White
White/Orange
Orange/White
White/Green
Green/White
White/Brown
1(DR)
2(VT)
3(0V)
4(BZ)
5(S2)
6(S1)
7(DS)
ON
PRIVACY
ON
PRIVACY
4 Pair CW1308 Colour Code
PL10
DR (Door Release)
VT (12v DC)
0V (0 Volts)
BZ (Buzz input)
S2 (Mic)
S1 (Speaker)
DS (Door Status)
V- (TP Video -)
V+ (TP Video +)
White/Blue + Blue/White
White/Orange + Orange/White
White/Green + White/Brown
White/Grey
Green/White
Brown/White
‘EX’ To Extension Sounders/
Flashing Beacons Only
6 Pair CW1308 Colour Code
Grey/White
Red/Blue
Blue/Red
Note:- Spare Blue / White shown in ‘DR’ may be
used to ‘Double-Up’ on VT or 0V if needed.
DR
VT
0V
BZ
S2
S1
DS
V-
V+
CB
X
EX
Entroview 300 / 400
Wiring Schematic
NOTE - The EX
connection is ONLY
to be used on
Entrotec Extension
sounders and
accessories. DO
NOT fit a wire into
EX for any other
purpose.
Any unused cores to be tied to
system 0v.
ONLY USE
CW1308 CABLE
PL10
Multiple ED3+ ED4+ & RH3+
Wiring Schematic (up to 3).
White/Blue
Blue/White
White/Orange
Orange/White
White/Green
Green/White
White/Brown
1(DR)
2(VT)
3(0V)
4(BZ)
5(S2)
6(S1)
7(DS)
ON
PRIVACY
ON
PRIVACY
4 Pair CW1308 Colour Code
1(DR)
2(VT)
3(0V)
4(BZ)
5(S2)
6(S1)
7(DS)
ON
PRIVACY
ON
PRIVACY
8(EX)
1(DR)
2(VT)
3(0V)
4(BZ)
5(S2)
6(S1)
7(DS)
8(V-)
9(V+)
1(DR)
2(VT)
3(0V)
4(BZ)
5(S2)
6(S1)
7(DS)
8(V-)
9(V+)
DR
VT
0V
BZ
S2
S1
DS
V-
V+
CB
X
EX
DR
VT
0V
BZ
S2
S1
DS
V-
V+
CB
X
EX
Spare port
supplies
12v & Video
1 port per
additional
handset reqd.
Handset port where call
is made to e.g. Phone 1
with 2 video handsets.
Mulitple Video
Handsets per call
(up to 3)
Separate Door Contacts
White/Blue + Blue/White
White/Orange + Orange/White
White/Green + White/Brown
White/Grey
Green/White
Brown/White
Grey/White
Blue/Red
Red/Blue
White/Blue + Blue/White
White/Orange + Orange/White
Blue/Red
Red/Blue
Orange/White

Page 7
Video Schematic (Dual or Single Entrance)
16 x 2 LCD Module
for Trade Clock Setting
Prog Right UP
SN SB DO CA SN SB DO CA
Door ‘B’ ConnectionsDoor ‘A’ Connections
RG59 to
Camera
RG59 to
Camera
SN SB DO CA SN SB DO CA
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
PL1
PL8 PL12 PL21 PL21
PL29
RG59 Crimp
Connector
RG59 Crimp
Connector
12 volt DC supply
PL17 +12V / 0v
Camera Camera
Camera signals are automatically switched from
Door ‘A’ to Door ‘B’ when calls are generated.
Preset Adjustments
Speech Time: Adjusts how long the user can talk for before the system resets.
Adjustable between 10 seconds and 2 minutes.
Callup Time: Adjusts how long the system stays ‘live’ for once a call has been made.
Adjustable between 10 seconds and 2 minutes.
Call Tone Time: Adjusts how long the call tone is emitted to the handsets and front panel.
Adjustable between 1 second and 25 seconds.
Reassurance Volume: Adjusts the volume of the call tone at the front panels and should be
set in accordance with ‘on-site’ conditions.
Door A Lock Timer: Adjusts the door open time period and should be adjusted to suit ‘on-
site’ requirements. 1 to 30 Seconds
Door B Lock Timer: Adjusts the door open time period and should be adjusted to suit ‘on-
site’ requirements. 1 to 30 Seconds
Video Adj. Video adjustment: Adjusts the video balance to fine tune the video picture
quality and should be adjusted ‘on-site’ to suit installation
conditions.
EliteMAN0113/ 7 of 12
Speech
Time
Callup
Time
Call Tone
Time
Reassurance
Volume
Door A
Lock Timer
Door B
Lock Timer
++
++ +
+
16 x 2 LCD Module
for Trade Clock Setting
Prog Right UP
Programming the ‘On Board’ Service/Trades Time Clock Page 8
On switch on of the system the screen will display ENTROTEC. Then display the Date, the day of the week, the timer status on line 1
ENTROTEC
Then time of day, nxon (next on period of timer) and the next on time as example below.
Note: When nxon displays 00;00 :-
Next on period is during
subsequent day.
Features:
Up to 12 daily programmable on/off periods.
Can be programmed by 5 day week (12 on/off periods).
Can be programmed by week end (12 on/off periods).
Can be programmed on an individual day basis (12 on/off periods).
To Edit time clock settings proceed as below:
If at anytime the timer is left for more than 10 seconds without any button ‘pushes’ it first asks if you would like to erase all settings
‘N’ for no being highlighted but to change to ‘Y’ for yes press the right button and then press Prog to confirm and save the settings. Or
after a further 10 seconds it asks you if you want to ‘Save Changes’ with again ‘N’ and ‘Y’ as above or leaving it alone for a further 10
seconds the timer reverts to original ‘non-programming’ mode.
To Change Date and Time: Press Prog button and the year will be displayed. To change the year press the Up button until the correct
year is displayed or if already correct press the Prog button again to display the month setting and press the Up button to correct the
month setting or if correct press the Prog button again to adjust the day setting by using the Up button. To change the time press the
Prog again and using the Right button select the hours, minutes or seconds that you want ot adjust and adjust using the Up button.
When any of the above have been adjusted leave for 10 seconds and the Save Changes Y/N screen will appear highlighting ‘N’ to
save your settings press the Right button to highlight ‘Y’ and press the Prog button.
To Change the Daily (DLY) On & Off Times. Press the Prog button 6 times and DLY 1 will be highlighted and it’s condition i.e On or
Off. To change the condition press the Up button. To adjust the time period first press the Right button to highlight either the hours or
minutes and use the Up button to adjust the time, leave for 10 seconds and the Save Changes Y/N screen will appear highlighting ‘N’
to save your settings press the Right button to highlight ‘Y’ and press the Prog button.
To Change the Week day (M-F) On & Off Times. Repeatedly press the Prog button until M-F 1 will be highlighted and it’s condition
i.e On or Off. To change the condition press the Up button. To adjust the time period first press the Right button to highlight either the
hours or minutes and use the Up button to adjust the time, leave for 10 seconds and the Save Changes Y/N screen will appear
highlighting ‘N’ to save your settings press the Right button to highlight ‘Y’ and press the Prog button.
To Change the Weekend (WKN) On & Off Times. Repeatedly press the Prog button until WKN 1 will be highlighted and it’s condition
i.e On or Off. To change the condition press the Up button. To adjust the time period first press the Right button to highlight either the
hours or minutes and use the Up button to adjust the time, leave for 10 seconds and the Save Changes Y/N screen will appear
highlighting ‘N’ to save your settings press the Right button to highlight ‘Y’ and press the Prog button.
.
To Change the Individual Day (Mon) On & Off Times. Repeatedly press the Prog button until MON 1 (or the appropriate day)
will be highlighted and it’s condition i.e On or Off. To change the condition press the Up button. To adjust the time period first press the
Right button to highlight either the hours or minutes and use the Up button to adjust the time, leave for 10 seconds and the
Save Changes Y/N screen will appear highlighting ‘N’ to save your settings press the Right button to highlight ‘Y’ and press the Prog
button.
30/08/07 THU ON
09;17 nxon 11;30
Timer On
Timer Off
Led’s showing timer status
EliteMAN0113/ 8 of 12

Page 7
Video Schematic (Dual or Single Entrance)
16 x 2 LCD Module
for Trade Clock Setting
Prog Right UP
SN SB DO CA SN SB DO CA
Door ‘B’ ConnectionsDoor ‘A’ Connections
RG59 to
Camera
RG59 to
Camera
SN SB DO CA SN SB DO CA
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
PL1
PL8 PL12 PL21 PL21
PL29
RG59 Crimp
Connector
RG59 Crimp
Connector
12 volt DC supply
PL17 +12V / 0v
Camera Camera
Camera signals are automatically switched from
Door ‘A’ to Door ‘B’ when calls are generated.
Preset Adjustments
Speech Time: Adjusts how long the user can talk for before the system resets.
Adjustable between 10 seconds and 2 minutes.
Callup Time: Adjusts how long the system stays ‘live’ for once a call has been made.
Adjustable between 10 seconds and 2 minutes.
Call Tone Time: Adjusts how long the call tone is emitted to the handsets and front panel.
Adjustable between 1 second and 25 seconds.
Reassurance Volume: Adjusts the volume of the call tone at the front panels and should be
set in accordance with ‘on-site’ conditions.
Door A Lock Timer: Adjusts the door open time period and should be adjusted to suit ‘on-
site’ requirements. 1 to 30 Seconds
Door B Lock Timer: Adjusts the door open time period and should be adjusted to suit ‘on-
site’ requirements. 1 to 30 Seconds
Video Adj. Video adjustment: Adjusts the video balance to fine tune the video picture
quality and should be adjusted ‘on-site’ to suit installation
conditions.
EliteMAN0113/ 7 of 12
Speech
Time
Callup
Time
Call Tone
Time
Reassurance
Volume
Door A
Lock Timer
Door B
Lock Timer
++
++ +
+
16 x 2 LCD Module
for Trade Clock Setting
Prog Right UP
Programming the ‘On Board’ Service/Trades Time Clock Page 8
On switch on of the system the screen will display ENTROTEC. Then display the Date, the day of the week, the timer status on line 1
ENTROTEC
Then time of day, nxon (next on period of timer) and the next on time as example below.
Note: When nxon displays 00;00 :-
Next on period is during
subsequent day.
Features:
Up to 12 daily programmable on/off periods.
Can be programmed by 5 day week (12 on/off periods).
Can be programmed by week end (12 on/off periods).
Can be programmed on an individual day basis (12 on/off periods).
To Edit time clock settings proceed as below:
If at anytime the timer is left for more than 10 seconds without any button ‘pushes’ it first asks if you would like to erase all settings
‘N’ for no being highlighted but to change to ‘Y’ for yes press the right button and then press Prog to confirm and save the settings. Or
after a further 10 seconds it asks you if you want to ‘Save Changes’ with again ‘N’ and ‘Y’ as above or leaving it alone for a further 10
seconds the timer reverts to original ‘non-programming’ mode.
To Change Date and Time: Press Prog button and the year will be displayed. To change the year press the Up button until the correct
year is displayed or if already correct press the Prog button again to display the month setting and press the Up button to correct the
month setting or if correct press the Prog button again to adjust the day setting by using the Up button. To change the time press the
Prog again and using the Right button select the hours, minutes or seconds that you want ot adjust and adjust using the Up button.
When any of the above have been adjusted leave for 10 seconds and the Save Changes Y/N screen will appear highlighting ‘N’ to
save your settings press the Right button to highlight ‘Y’ and press the Prog button.
To Change the Daily (DLY) On & Off Times. Press the Prog button 6 times and DLY 1 will be highlighted and it’s condition i.e On or
Off. To change the condition press the Up button. To adjust the time period first press the Right button to highlight either the hours or
minutes and use the Up button to adjust the time, leave for 10 seconds and the Save Changes Y/N screen will appear highlighting ‘N’
to save your settings press the Right button to highlight ‘Y’ and press the Prog button.
To Change the Week day (M-F) On & Off Times. Repeatedly press the Prog button until M-F 1 will be highlighted and it’s condition
i.e On or Off. To change the condition press the Up button. To adjust the time period first press the Right button to highlight either the
hours or minutes and use the Up button to adjust the time, leave for 10 seconds and the Save Changes Y/N screen will appear
highlighting ‘N’ to save your settings press the Right button to highlight ‘Y’ and press the Prog button.
To Change the Weekend (WKN) On & Off Times. Repeatedly press the Prog button until WKN 1 will be highlighted and it’s condition
i.e On or Off. To change the condition press the Up button. To adjust the time period first press the Right button to highlight either the
hours or minutes and use the Up button to adjust the time, leave for 10 seconds and the Save Changes Y/N screen will appear
highlighting ‘N’ to save your settings press the Right button to highlight ‘Y’ and press the Prog button.
.
To Change the Individual Day (Mon) On & Off Times. Repeatedly press the Prog button until MON 1 (or the appropriate day)
will be highlighted and it’s condition i.e On or Off. To change the condition press the Up button. To adjust the time period first press the
Right button to highlight either the hours or minutes and use the Up button to adjust the time, leave for 10 seconds and the
Save Changes Y/N screen will appear highlighting ‘N’ to save your settings press the Right button to highlight ‘Y’ and press the Prog
button.
30/08/07 THU ON
09;17 nxon 11;30
Timer On
Timer Off
Led’s showing timer status
EliteMAN0113/ 8 of 12

Page 9
Handset Auxiliary Equipment Connections.
1
4
Set J1 up
and J2 down
DR
VT
0V
BZ
S2
S1
DS
X
EX
V-
V+
CB
ED+ Series Handsets
Entroview Series handsets
and Apartment Stations
WE/BE
BE/WE
WE/OE
TRG
RESET
COM
COM
N/C
N/C
N/O
N/O
12V
0V
Mountcastle Relay
2 sets of volt free C/O contacts
rated at 1 amp.
Note :-
The EX connection is
only used on these
accessories and additional
handsets. Do not
fit a wire into EX for
any other purpose.
Note: Fit jumper link PL4
to enable EX output
Marshalling
Marshalling
Note: These volt free contacts
maybe used to trigger door bells,
additional sounders, Silent Bell
units etc using external power
supplies. An example of using
a door bell is shown below.
RELAY
TRG
RESET
COM
COM
N/C
N/C
N/O
N/O
12V
0V
Door
Bell
PSU
230~
Input
Door
Bell
+
_
Front Door Bell Push
(if fitted).
Delay off time adjust
Flashing Beacon
Black
Red
Timer ENT9876/1
TRG 0v 12v COM N/C N/O
RELAY
TRG
RESET
COM
COM
N/C
N/C
N/O
N/O
12V
0V
EliteMAN0113/ 10 of 12
EliteMAN0113/ 9 of 12
124 3 3
Microswitch
Grey Wire = 16/0.2 (NO Connection).
Brown Wire = 1.5mm (NC Connection).
FS4 or 5 Fire Switch
124 3
Microswitch
Grey Wire = 16/0.2 (NO Connection).
Brown Wire = 1.5mm (NC Connection).
PTE/EPTE Push to Exit Switch
To Push to Exit Common
See wire ‘C’ in table.
To Push to Exit Input
See wire ‘B’ in table.
To Lock 12v Supply
See wire ‘A’ in table.
2
1.5mm Flex (Brown)
To Lock +
To Lock -
From System Switched Negative
See table below
2
1.5mm 2 core Flex
Brown Wire
Blue Wire
CW1308 2 Pair
A
Link Wire (A2)
C
D
E
Connection Terminal: Apex DP Elite Cont. Entrocare DP E100 E2000 KMS Simple Key PAC 512
B
2
Wire A (Brown 1.5mm )
Wire B (CW1308)
Wire C (CW1308)
2
Wire D (Brown 1.5mm )
2
Wire E (Blue 1.5mm )
PL1/12V PL6/12V
(PL28/12V) PL1/12V 12V Lock 2/+12V
PL3/0V PL3/0V
PL3/PE PL3/PE
Lock +
or BGU
Lock +
or BGU
Lock +
or BGU
Lock +
or BGU
Lock +
or BGU
Lock +
or BGU
Lock +
or BGU
PL1/NC PL1/NC
PL5/C
(PL33/C)
PL5/PE
(PL33/PE)
PL6/NC
(PL28/NC)
Door1 0V
(Door2 0v)
Door1REX
(Door2REX)
Door1 NC
Relay
(Door2 NC)
31/N/C
(34/N/C)
11/GND
DC Out +
Door Lock1 NC
(Door Lock 2 NC)
GND 1
(GND 2)
RTE 1
(RTE 2)
9/OL1
(10/OL2)
Access/Lock
Door 1 0V
(Door 2 0V)
Door 1 RTE
(Door 2 RTE)
Lock 1 NC
(Lock 2 NC)
Connection Table:
Note: Connections in brackets are for 2nd door connections. Also note if system Door Entry DE then all connections
for locks are made at the Door Entry System (i.e. Access Controllers trigger Door Entry PE inputs with a NO 0V).
From ‘A’ if PTE Only
Page 10
FS4/5 & PTE/EPTE Wiring Diagram.
NC
NO
NC
NO
FS PTE
AA2 D D
+
-
D
C
B1N4007
Diode
E
If Fitted
Fail Safe Lock
FA/
AOV BGU
Schematic
I/O BY
Others
FA/AOV
NC NC
Grey Wire = 16/0.2 (NO Connection).
Brown Wire = 1.5mm (NC Connection).
Grey Wire = 16/0.2 (NO Connection).
Brown Wire = 1.5mm (NC Connection).
0v
12v
TRG
NO
12v
0v
TRG
TRG
12v
0v
COM
NO
TRG

Page 9
Handset Auxiliary Equipment Connections.
1
4
Set J1 up
and J2 down
DR
VT
0V
BZ
S2
S1
DS
X
EX
V-
V+
CB
ED+ Series Handsets
Entroview Series handsets
and Apartment Stations
WE/BE
BE/WE
WE/OE
TRG
RESET
COM
COM
N/C
N/C
N/O
N/O
12V
0V
Mountcastle Relay
2 sets of volt free C/O contacts
rated at 1 amp.
Note :-
The EX connection is
only used on these
accessories and additional
handsets. Do not
fit a wire into EX for
any other purpose.
Note: Fit jumper link PL4
to enable EX output
Marshalling
Marshalling
Note: These volt free contacts
maybe used to trigger door bells,
additional sounders, Silent Bell
units etc using external power
supplies. An example of using
a door bell is shown below.
RELAY
TRG
RESET
COM
COM
N/C
N/C
N/O
N/O
12V
0V
Door
Bell
PSU
230~
Input
Door
Bell
+
_
Front Door Bell Push
(if fitted).
Delay off time adjust
Flashing Beacon
Black
Red
Timer ENT9876/1
TRG 0v 12v COM N/C N/O
RELAY
TRG
RESET
COM
COM
N/C
N/C
N/O
N/O
12V
0V
EliteMAN0113/ 10 of 12
EliteMAN0113/ 9 of 12
124 3 3
Microswitch
Grey Wire = 16/0.2 (NO Connection).
Brown Wire = 1.5mm (NC Connection).
FS4 or 5 Fire Switch
124 3
Microswitch
Grey Wire = 16/0.2 (NO Connection).
Brown Wire = 1.5mm (NC Connection).
PTE/EPTE Push to Exit Switch
To Push to Exit Common
See wire ‘C’ in table.
To Push to Exit Input
See wire ‘B’ in table.
To Lock 12v Supply
See wire ‘A’ in table.
2
1.5mm Flex (Brown)
To Lock +
To Lock -
From System Switched Negative
See table below
2
1.5mm 2 core Flex
Brown Wire
Blue Wire
CW1308 2 Pair
A
Link Wire (A2)
C
D
E
Connection Terminal: Apex DP Elite Cont. Entrocare DP E100 E2000 KMS Simple Key PAC 512
B
2
Wire A (Brown 1.5mm )
Wire B (CW1308)
Wire C (CW1308)
2
Wire D (Brown 1.5mm )
2
Wire E (Blue 1.5mm )
PL1/12V PL6/12V
(PL28/12V) PL1/12V 12V Lock 2/+12V
PL3/0V PL3/0V
PL3/PE PL3/PE
Lock +
or BGU
Lock +
or BGU
Lock +
or BGU
Lock +
or BGU
Lock +
or BGU
Lock +
or BGU
Lock +
or BGU
PL1/NC PL1/NC
PL5/C
(PL33/C)
PL5/PE
(PL33/PE)
PL6/NC
(PL28/NC)
Door1 0V
(Door2 0v)
Door1REX
(Door2REX)
Door1 NC
Relay
(Door2 NC)
31/N/C
(34/N/C)
11/GND
DC Out +
Door Lock1 NC
(Door Lock 2 NC)
GND 1
(GND 2)
RTE 1
(RTE 2)
9/OL1
(10/OL2)
Access/Lock
Door 1 0V
(Door 2 0V)
Door 1 RTE
(Door 2 RTE)
Lock 1 NC
(Lock 2 NC)
Connection Table:
Note: Connections in brackets are for 2nd door connections. Also note if system Door Entry DE then all connections
for locks are made at the Door Entry System (i.e. Access Controllers trigger Door Entry PE inputs with a NO 0V).
From ‘A’ if PTE Only
Page 10
FS4/5 & PTE/EPTE Wiring Diagram.
NC
NO
NC
NO
FS PTE
AA2 D D
+
-
D
C
B1N4007
Diode
E
If Fitted
Fail Safe Lock
FA/
AOV BGU
Schematic
I/O BY
Others
FA/AOV
NC NC
Grey Wire = 16/0.2 (NO Connection).
Brown Wire = 1.5mm (NC Connection).
Grey Wire = 16/0.2 (NO Connection).
Brown Wire = 1.5mm (NC Connection).
0v
12v
TRG
NO
12v
0v
TRG
TRG
12v
0v
COM
NO
TRG

240v ~
Typical Elite Functional Main Entrance Door Schematic
Entrotec Elite Door Entry Controller
Functional Door Panel
Access
Control
Reader
Fireman Switch
(Double Pole
2 or 3 Switch).
Main Push to Exit
(Double Pole
Push to Exit).
Front Door
To Handsets
Individual cables
ON
PRIVACY
4 Pair CW1308
or 6 Core Alarm
Cable.
See Cabling Table
2
2 Pair + 2 x 1.5mm
See Note
2
2 Pair + 2 x 1.5mm
See Note
Access Control Controller
3 x 1.5mm Brown
Blue, Earth Stranded
Flex or singles.
2 pair CW1308
To Fire Alarm
(Volt free N/C contacts)
To Telecom Line
To Slave Access Controllers
RG59 if Video
Camera
if video
Modem
To IRS System
2 x Magnetic locks
Magnetic Lock
(monitored
magnetic lock).
Magnetic Lock
(unmonitored
magnetic lock).
Top Magnetic
Lock
Bottom Magnetic
Lock
6 Pair CW1308 Entroview 100
Privacy
Or
EliteMAN0113/ 11 of 12
6 Pair CW1308
to LCD
LCD
4 pair CW1308
Cabling Table
VRP01S - VRP05S = 4 & 6 Pair CW1308
VRP06S (7) - VRP12S = 8 & 6 Pair CW1308
VRP13S (14) - VRP16S = 10 & 6 Pair CW1308
Add RG59B cable if video is required from
2
camera to controller + 2 core 0.75mm flex
Access control reader cables must be run separately
and in accordance with manufacturers recommendations.
These cable
amounts are
minimum
reqd.
EliteMAN0113/ 12 of 12
Wiring Key
2
A = = 2 cores 1.5mm Flex to Magnetic Locks.
B = = 2 Pair CW1308 to Magnetic Lock Contacts.
C = = 3 Pair CW1308 to Prox Readers.
2
D = = 3 Pair CW1308 + 2 core 1.5mm Flex to PTE, FS & magnetic locks (Lock 12VDC Supply).
E = = 4 Pair CW1308 to Audio Handsets.
F = = CW1308 to door panel (See table for no.of cores) + 1 x 6 Pair for LCD
G = = 6 Pair CW1308 to video handsets (for apartment stations use 8 or 10 pair).
H = = 1 core RG59 from panel or dome camera.
2
J = = 2 core 0.75mm flex (12VDC) for camera power.
ON
PRIVACY
ON
PRIVACY
ED3+ or 4+ Handset
IF Dual Entrance repeat for Door 2
G
Entroview 300
On Privacy
Door Open
Entroview 300
FS4/BZ/DP = Double pole fire switch.
Prox/BZ/T11 = Prox stand-alone reader.
PTE/YR = Double pole push to exit.
PTE/EPTE/YR = Double pole push to exit.
Resetable Call Point (Break Glass Unit BGU).
AOV (by Fire Alarm Co.) NC contacts opening
on Fire Alarm activation
EliteXXXX= Elite Functional Panel c/w Prox Reader.
M32SC = Securitron M32 (monitored) or similar.
230v mains input to un-switched fused spur. All
controllers and system metalwork Must Be Earthed.
Equipment Key All metalwork to be earthed
PUSH
TO EXIT
FIRE
1
4466
7 9
00
4
6
7
Trade
3
5
1
8
2
Break
Glass
PUSH
TO EXIT
In emergency press
and hold exit button
while opening door
230V~
AOV
If Fitted
NC Contacts
opened if Fire
Elite Main Controller
(8 or 16 way)
C/W Prox Controller
230V~
PUSH
TO EXIT
FIRE
Dome
Camera
Break
Glass
A
JC
D
B
AOV
If Fitted
NC Contacts
opened if Fire
F
MED1
1
4466
7 9
00
4
6
7
Trade
3
5
1
8
2
H
E

240v ~
Typical Elite Functional Main Entrance Door Schematic
Entrotec Elite Door Entry Controller
Functional Door Panel
Access
Control
Reader
Fireman Switch
(Double Pole
2 or 3 Switch).
Main Push to Exit
(Double Pole
Push to Exit).
Front Door
To Handsets
Individual cables
ON
PRIVACY
4 Pair CW1308
or 6 Core Alarm
Cable.
See Cabling Table
2
2 Pair + 2 x 1.5mm
See Note
2
2 Pair + 2 x 1.5mm
See Note
Access Control Controller
3 x 1.5mm Brown
Blue, Earth Stranded
Flex or singles.
2 pair CW1308
To Fire Alarm
(Volt free N/C contacts)
To Telecom Line
To Slave Access Controllers
RG59 if Video
Camera
if video
Modem
To IRS System
2 x Magnetic locks
Magnetic Lock
(monitored
magnetic lock).
Magnetic Lock
(unmonitored
magnetic lock).
Top Magnetic
Lock
Bottom Magnetic
Lock
6 Pair CW1308 Entroview 100
Privacy
Or
EliteMAN0113/ 11 of 12
6 Pair CW1308
to LCD
LCD
4 pair CW1308
Cabling Table
VRP01S - VRP05S = 4 & 6 Pair CW1308
VRP06S (7) - VRP12S = 8 & 6 Pair CW1308
VRP13S (14) - VRP16S = 10 & 6 Pair CW1308
Add RG59B cable if video is required from
2
camera to controller + 2 core 0.75mm flex
Access control reader cables must be run separately
and in accordance with manufacturers recommendations.
These cable
amounts are
minimum
reqd.
EliteMAN0113/ 12 of 12
Wiring Key
2
A = = 2 cores 1.5mm Flex to Magnetic Locks.
B = = 2 Pair CW1308 to Magnetic Lock Contacts.
C = = 3 Pair CW1308 to Prox Readers.
2
D = = 3 Pair CW1308 + 2 core 1.5mm Flex to PTE, FS & magnetic locks (Lock 12VDC Supply).
E = = 4 Pair CW1308 to Audio Handsets.
F = = CW1308 to door panel (See table for no.of cores) + 1 x 6 Pair for LCD
G = = 6 Pair CW1308 to video handsets (for apartment stations use 8 or 10 pair).
H = = 1 core RG59 from panel or dome camera.
2
J = = 2 core 0.75mm flex (12VDC) for camera power.
ON
PRIVACY
ON
PRIVACY
ED3+ or 4+ Handset
IF Dual Entrance repeat for Door 2
G
Entroview 300
On Privacy
Door Open
Entroview 300
FS4/BZ/DP = Double pole fire switch.
Prox/BZ/T11 = Prox stand-alone reader.
PTE/YR = Double pole push to exit.
PTE/EPTE/YR = Double pole push to exit.
Resetable Call Point (Break Glass Unit BGU).
AOV (by Fire Alarm Co.) NC contacts opening
on Fire Alarm activation
EliteXXXX= Elite Functional Panel c/w Prox Reader.
M32SC = Securitron M32 (monitored) or similar.
230v mains input to un-switched fused spur. All
controllers and system metalwork Must Be Earthed.
Equipment Key All metalwork to be earthed
PUSH
TO EXIT
FIRE
1
4466
7 9
00
4
6
7
Trade
3
5
1
8
2
Break
Glass
PUSH
TO EXIT
In emergency press
and hold exit button
while opening door
230V~
AOV
If Fitted
NC Contacts
opened if Fire
Elite Main Controller
(8 or 16 way)
C/W Prox Controller
230V~
PUSH
TO EXIT
FIRE
Dome
Camera
Break
Glass
A
JC
D
B
AOV
If Fitted
NC Contacts
opened if Fire
F
MED1
1
4466
7 9
00
4
6
7
Trade
3
5
1
8
2
H
E

Entrotec Limited
Access House
5, Ashwood Court, Oakbank
Livingston. EH53 0TL
Tel: 01506 886230 Fax: 01506 886233
Customer Support: 08448586370
Web: www.entrotec.com
Online Shop: www.entrotec-online.co.uk
Manufactured in the UK
Other manuals for ELITE
1
This manual suits for next models
1
Table of contents
Other Entrotec Intercom System manuals
Popular Intercom System manuals by other brands

AES
AES StylusAB Installation & user manual

urmet domus
urmet domus modo 1719 Installation and use manual

Vimar
Vimar Elvox 6604/AU operating instructions

Securam
Securam SafeLogic Basic EC-0601A Series operating instructions

VnetPhone
VnetPhone Riders V4 manual

Intratone
Intratone LABEL MODULE installation instructions

Comelit
Comelit MT SB2 01 Technical manual

M-E
M-E VDV-610 COMPACT operating instructions

Digitus Biometrics
Digitus Biometrics dbNEXII user manual

Aiphone
Aiphone GW-LE8 instructions

NuTone
NuTone LA-204WH Installation & operating instructions

Zenitel
Zenitel VINGTOR STENTOFON ECP-AA1 Installation, configuration & operation