Entryvue 13505 User manual

VIDEO DOOR PHONE SYSTEM
USER MANUAL (English)
Item No. : 13505
Version2.0.1.1.3.28
The design and specifications can be changed without notice to users.
Copyright of this manual is reserved.

CONTENTS
- - - - - - - - - - - - - - - - - - - - - - - - - - - - 1
- - - - - - - - - - - - - - - - - - - - - - - - - - 1
- - - - - - - - - - - - - - - - - - - - - - - - - - - 2
- - - - - - - - - - - - - - - - - - - - - - - 2
3.2 Placing Name Label - - - - - - - - - - - - - - - - - - - - - - - - - - 3
- - - - - - - - - - - - - - - - - - - - - - 3
- - - - - - - - - - - - - - - - - - - - - - - - - 4
- - - - - - - - - - - - - - - - - - - 4
- - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
- - - - - - - - - - - - - - - - - - - - - - 5
4.2.1 Door Lock Controlled by Internal Power - - - - - - - 5
4.2.2 Door Lock Controlled by Dry Contact - - - - - - - - - - 5
4.2.3 How to setup the unlock parameter in Monitor - - 6
- - - - - - - - - - - - - - - - 7
- - - - - - - - - - - - - - - - - - - 8
4.4.1 Basic IN-OUT Wiring Mode - - - - - - - - - - - - - - - - 8
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9
- - - - - - - - - - - - 9
- - - - - - - - - - - - -- - 9
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11
-1-
128mm
178mm
Microphone
Camera Lens
LED Indicator
Speaker
178mm
16.5mm
59mm
1 2 3 4 5 6
ON DIP
MIC adjustment
SPK adjustment
Lock Control Jumper
JP-LK
CN-LK
BUS
RS485
123
EB+
T/R-
SET
T/R+
EB-
N.O.
LK+(COM)
LK-(GND)
+12V

-2-
•+12V: 12VDC power output.
•LK-(GND): power ground.
•LK+(COM):
•NO.: electronical load relay normally open contact(refer to DT technical guide for
•EB+:
•EB-: Exit buton.
•JP-LK:
•T/R-:
•T/R+:
•SET: DIP
•PA:
•PB:
•Bus(L1,L2): non-polarised bus line.
21
34
-3-
3.2 Placing Name Label
Use a screwdriver to open the
,revoclebalemantnerapsnart
insert a name paper, then put the
use one hand to hold the unit and another
hand with a screwdriver to loosen the screw
and then adjust the angle of the camera ,then
fix the screw.

-4-
-
+
AC~
monitor
DPS PS4
Y
•Single Mode: that means the door only has one can only call the monitor with
it's code among 00~15.please refer to 5.2.
•Double Mode:that means the door has two A can call the adress 00~15
of the monitor r.please refer to 5.2.
1. Single set the DIP swiches of Bit 3 on door station to 'on' state (refer to 5.1), single
2. Double .set the DIP swiches of Bit 3 on door to 'off' state (refer to 5.1),double
-5-
4.2.1 Door Lock Controlled by Internal Power
Note:
1. Only available to power on the unlock type os electoric lock.
2. The door lock is limited to 12V, and holding current must be less than 250mA.
3.
4. TheUnlock Mode Parameter of Monitor must be set to 0 (by default).
4.2.2 Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according to the lock.
2. The inside relay contact is restricted to AC or DC 24V/3A.
3. The jumper must be taken off
4. Setup the Unlock Mode of Monitor for different lock types.
•Power-on-to-unlock type:Unlock Mode=0 (by default)
•Power-off-to-unlock type:Unlock Mode=1
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
L1
T/R -
T/R+
RS-485
JP-LK
BUS
L2
Connect to DPS
1
2
3
LOCK EB
Jumper posi on in 1-2
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
L1
T/R -
T/R+
RS-485
JP-LK
BUS
L2
Connect to DPS
1
2
3
LOCK
Take offthe Jum
cut the red wire
per
POWER
SUPPLY

-6 -
4.2.3 How to setup the unlock parameter in Monitor
monitor
intercom
setup
exit
Outdoor Tone -- 01
Intercom Tone -- 05
Monitor Time -- 1min
Advanced Set...
Auto Record -- OFF
Exit
0
* * *
Password:
Slave Addr Set -- 0
Guard Unit Set -- 0
Date/Time Set...
Other Settings...
Information...
Exit
Hardware ver 0302
Software ver 0168
Voltage 22.4V
Manufacture 00.0T
Restore to default
Exit
Unlock Time 1
Unlock Mode 0
Exit
1.Press MENU bu on twice
to ent er the MAIN M ENU
page, then press setup.
2.Select Advanced Set...
and press MENU to
4.Select
and press MENU to
enter next page.
Note:
y, so you only need to set on one monitor.
3.the above are not fit for T-views series monitors. Please refer to T-views series
monitor user manual to how to set the unlock parameter.
5.Press UNLOCK n
and hold for 2s.
6.Use / to select the
item, use / to change
the value of the item. Select
Exit
press MENU
y.
3.The default password is
2008. Press / to
change the lock, Press /
bu on to select the loca on,a er
finishing, press MENU to
enter next step.
-7 -
85~260VAC
DPS PS5
monitors
L1 L2 L1 L2 L1 L2 L1 L2
1# Camera
ID=00
ID=10
ID=01
ID=11
2# Camera3# Camera
4# Camera
1 2 3 4 5 6
ON
1 2 3 4 56
ON
1 2 3 4 56
ON
1 2 3 4 5 6
ON
enter is required.

-8-
4.4.1 Basic IN-OUT Wiring Mode
ID=00
Code=0, DIP-6=off
Code=30, DIP-6=off
Code=31, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
85~260AC
DPS PS5
monitor
monitor
monitor
1 2 3 4 5 6
ON
1 2 3 4 56
ON
Note:
-9-
Attention: You must follow the dip switch settings in the table on page 11 .
So, 1st monitor all switches down, 2nd monitor switch 1 up, 3rd monitor
switch 2 up, etc.
5.DIP
5.2 DIP
5.1 DIP
There are 6 bit switches in total. The DIP switches are used to configure the User Code for each
Monitor.
Bit-6 is line terminal switch, which have to be set to ON if the Monitor is at the end of the line(bus),
otherwise set to OFF.
Bit state Setting Bit state Setting
sirotinomehT
not at the end
of the bus.
The monitor
is at the end
of the bus.
123 4 5 6
ON
123 4 5 6
ON
ON(1)
=
OFF(0)
=
ON
ON
ON
12345 6
Total 6 bits in the DIP switches can be co
•
two bit must be set correctly,
to 10, the fourth one set to 1
•Bit-3: Single mode or double line mode for door set 'on' state to be
ff
•Bit-4:reserved and unused.
•Bit-5: Unlocking quick by default it is set to 0, for 1 second unlocking set to 1 for 5
seconds.
•Bit-6: reserved and unused.
installaon, but the power supply needs to be restated whenever the switches have been modified.

-10--11-
Bit state User Code Bit state User Code Bit state User Code
22=edoC11=edoC0=edoC
21=edoC1=edoC
1 2 3 4 56
ON
Code=23
31=edoC2=edoC
1 2 3 4 56
ON
Code=24
41=edoC3=edoC
1 2 3 4 56
ON
Code=25
51=edoC4=edoC
1 2 3 4 5 6
ON
Code=26
61=edoC5=edoC
1 2 3 4 5 6
ON
Code=27
71=edoC6=edoC
1 2 3 4 56
ON
Code=28
81=edoC7=edoC
1 2 3 4 5 6
ON
Code=29
91=edoC8=edoC
1 2 3 4 5 6
ON
Code=30
02=edoC9=edoC
1 2 3 4 56
ON
Code=31
Code=10 Code=21
The value is from 0 to 31, which have 32 different codes .
1 2 3 4 56
ON
1 2 3 4 5 6
ON
1 2 3 4 56
ON
1 2 3 4 56
ON
1 2 3 4 56
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 56
ON
1 2 3 4 56
ON
1 2 3 4 56
ON
1 2 3 4 56
ON
1 2 3 4 56
ON
1 2 3 4 56
ON
1 2 3 4 56
ON
1 2 3 4 56
ON
1 2 3 4 56
ON
1 2 3 4 5 6
ON
1 2 3 4 56
ON
1 2 3 4 5 6
ON
1 2 3 4 56
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
AB
Note:
1. If the mode is set to single mode for door
2. If the mode is set to double for door
response A must set the user code
)rewoPlanretnI(Am003,cdV21:ylppusrewoPkcoL
gnikrowniW21,ybdnatsniW1:noitmusnoCrewoP
A5.1cdV84.xaM:tcatnocyrdMOC,ON
rotinoMybtes,sdnoces9ot1:emitgnikcolnU
Cº54~Cº01-:erutarepmetgnikroW