TECHNICAL DATA
(Modification rights reserved)
Protocol setting:
Address, baudrate, parity and stop bits can be set via:
1. Product Congurator Software (available on www.epluse.com/EE210)
2. Modbus protocol (please see Application Note Modbus (available on www.epluse.com/EE210)
FLOAT (read register):
Register
address
Communication
address
Parameter
name
30026 0x19 temperature [°C], [°F]
30028 0x1B relative humidity [%]
30030 0x1D water vapour partial pressure [mbar], [psi]
30032 0x1F dew point temperature [°C], [°F]
30036 0x23 absolute humidity [g/m³], [g/ft³]
30038 0x25 mixing ratio [g/kg], [gr/lb]
30040 0x27 specic enthalpy [kJ/kg], [BTU/lb]
30042 0x29 frost point temperature [°C], [°F]
INTEGER (read register):*
Register
address
Communication
address
Parameter
name
30301 0x12C temperature [°C], [°F]
30302 0x12D relative humidity [%]
30303 0x12E water vapour partial pressure [mbar], [psi]
30304 0x12F dew point temperature [°C], [°F]
30306 0x131 absolute humidity [g/m³], [g/ft³]
30307 0x132 mixing ratio [g/kg], [gr/lb]
30308 0x133 specic enthalpy [kJ/kg], [BTU/lb]
30309 0x134 frost point temperature [°C], [°F]
* Values are stored with a scaling of 1:100 (e.g.: 2550 is equivalent to 25.5°C)
INTEGER (write register):*
Register
address
Communication
address
Parameter
name
60001 0x00 Slave-ID (modbus addresse)
60002 0x01 Modbus protocol settings*
*For Modbus protocol setting please see Application Note Modbus
(www.epluse.com/EE210)
INFO (read register):
Register
address
Communication
address
Parameter
name
30001 0x00 Serial number (as ASCII)
30009 0x08 Firmware version
The measured values are saved as a 32 Bit float value from 0x19 to 0x1F and from 0x23 to 0x29. Additionally the measured values
are available as 16 Bit signed integer from 0x12C to 0x12F and from 0x131 to 0x134.
The factory setting for the Slave-ID (Modbus address) is 242 as an integer 16Bit value. This ID can be changed by the user in the
register 60001 (0x00), permitted values are 1 - 247 permitted.
The serial number as ASCII-code is located at register address 30001-30008 (16 Bit per address).
The Firmware version is located at register address 30009 (Bit 15...8 = major release; Bit 7...0 = minor release).
The choice of measurement units (metric or not metric) must be done in the ordering guide, see EE210 data sheet.
Switching from metric to non metric or vice versa by using the EE-PCS is not possible.
DIGITAL SETTINGS
BACnet PICS are abvailable for download at www.epluse.com/EE210
BACnet Setup
Modbus Setup
Address Switch
Address Switch
Slave address setting via EE-PCS Product Conguration Software:
All switches at position 0 → address has to be set via Product Conguration Software
(factory setting 242).
Example: Slave address is set via conguration software.
Slave address setting via Dip-Switch:
Setting the Dip-Switch to any other address than 0 overwrites the slave address set
via conguration software.
Example: Slave address set to 11 (=00001011 binary).
0
1
0
1
0 0 0 0 0 0 0 0
1 1 0 1 0 0 0 0
Measured Values
Relative Humidity (RH)
Sensor E+E Sensor HCT01-00D
Working range 0...100 % RH
RH accuracy (incl. hysteresis, non-linearity and repeatability)
Wall & duct version:
-15...40 °C (5...104 °F) ≤90 % RH ±(1.3 + 0.003*measured value) % RH
-15...40 °C (5...104 °F) >90 % RH ± 2.3 % RH
-40...60 °C (-40...140 °F) ±(1.5 + 0.015*measured value) % RH
Remote probe version
at 20 °C (68 °F) ±2.5 % RH