p 3
Eraser Company Inc. • Syracuse, NY USA • Ph: 315-454-3237 • info@eraser.com • www.eraser.com • Fax 315-454-3090
INSERT INSTALLATION: Remove the clear plastic
guard. The collet has two parts. The rst holds the
stripping insert and is mounted on the motor shaft by
use of a set screw. The second part (nut) screws onto
the rst part and varies the pressure on the insert
to allow adjustability for dierent wire sizes. It is not
necessary to remove the collet assembly from the
motor shaft to install the stripping insert. Unscrew the
front part of the collet from the insert holder. Slide the
insert into the holder, aligning the slots in the insert
with the slots in the holder. The insert should protrude
1/8” - 3/16” (3.1 - 4.8mm) from the front of the collet.
*See Insert Selection Guide.
STRIP LENGTH STOP: The Model L1 has a strip
length stop rod that protrudes from the motor shaft
and is held in place by a small set screw on the
motor shaft. Using the larger of the 3 Allen wrenches
provided, loosen the set screw holding the collet
assembly to the motor shaft, and slide the assembly
o the shaft. Adjust the strip length rod to the desired
position using the smaller of the Allen wrenches
provided. Replace the collet assembly with stripping
insert and the plastic guard.
After replacing the collet assembly and guards on
the unit, connect the unit to the power supply.
OPERATION:
NOTE: Safety glasses or other suitable eye
protection should be worn when using these units.
Turn the unit on. Insert the wire into the stripping
insert. The wire will strip while being pushed in, not
while being withdrawn. If the wire does not strip,
turn the unit o, remove the guard and use the collet
adjusting wrenches to tighten the insert further.
Replace the guard and try stripping the wire again.
Repeat this procedure as often as necessary until a
satisfactory strip is achieved.
If using the strip length stop insert the wire until it
butts against the stop, then withdraw. Once set, the
unit may be used continuously.
MAINTENANCE:
Keep the unit clean and free of insulation dust, and
replace inserts when worn. No other maintenance is
required.
TROUBLE SHOOTING:
PROBLEM: Wire does not strip.
SOLUTIONS:
1) Check that insert size is correct for wire being
stripped.
2) Tighten collet on insert.
3) Check that insert is pushed back far enough into
the collet.
4) Check if insert is worn, and replace.
PROBLEM: Wire breaks when inserted.
L1 Magnet Wire Stripper
Strip Length Stop Insulation is
removed as
wire is inserted
WIRE SIZE CARBIDE TIPPED INSERTS
Concave Face Flat Face Bullet Nose
29-24 AWG (0.28-0.51mmø) L30CC-IR9007 L30CF-IR9008 L30CB-IR9009
24-20 AWG (0.51-0.81mmø) L35CC-IR9017 L35CF-IR9018 L35CB-IR9019
20-16 AWG (081-1.30mmø) L31CC-IR9027 L31CF-IR9028 L31CB-IR9029
15-13 AWG (1.45-1.83mmø) L33CC-IR9037 L33CF-IR9038 L33CB-IR9039
WIRE SIZE HEAVY DUTY GRADE INSERTS
Concave Face Flat Face Bullet Nose
29-24 AWG (0.28-0.51mmø) L30HC-IR1951 L30HF-IR1961 L30HB-IR1981
24-20 AWG (0.51-0.81mmø) L35HC-IR1952 L35HF-IR1962 L35HB-IR1982
20-16 AWG (081-1.30mmø) L31HC-IR1953 L31HF-IR1963 L31HB-IR1983
15-13 AWG (1.45-1.83mmø) L33HC-IR1954 L33HF-IR1964 L33HB-IR1984