ESP Aperta User manual

USER MANUAL
www.espuk.com
EZTAG3 | PROXIMITY AND KEYPAD DOOR ENTRY
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 1

2
System Components
Proximity and Keypad Reader 10 x Proximity Tags 1 x Hex Key
4 x Plastic wall plug
4 x Countersunk screws
1 x Diode and 1 x Capacitor
Optional Accessories
EVBPSBB
Lock Power Supply
EV-EXIT
Push to Release
EV-EBG
Emergency Release
EV-ML-250/500XT
Electro-magnetic Lock
ENTERD
Electric Lock
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 2

3
Contents
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
EZTAG3 Wiring Example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
EZTAG3 Wiring Example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Advanced Programming Guide
How to set-up Access Pin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
How to set-up Access Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Deleting Access Pin or Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Changing Programming Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Clear all Pin and Tag Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Default to Factory Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Lock 1 Output Operating Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Enable ‘Door Bell’ Facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Enable ‘Tamper Alarm’ facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Access Pin Number for Lock 2 Output . . . . . . . . . . . . . . . . . . . . . . . . 10
Deleting Access Pin for Lock 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Lock Output Operating Time for Lock 2 Output . . . . . . . . . . . . . . . . 11
System setup record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
User Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Technical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 3

4
Installation
Note: if using more than one keypad, ensure that the keypads are mounted a minimum 185cm apart
(Side View)
Push the keypad up to release from mount plate
Release hex screw from
the bottom of the keypad
Thread system cable through the cable entry hole then make
the system connections (as per the wiring diagram), mount the
bracket to the surface and slide the keypad to the mountplate,
re-fit the hex screw to secure into position.
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 4

5
EZTAG3 Wiring Example 1
4
3
+
+
+
_
_
_
Red
NC
Black
Green
Purple
Grey
Pink
Electro-magnetic lock Electronic lock
Tag Reader
Indication LEDs
Keypad
Tag Reader
Indication LEDs
Keypad
EZTAG3 Wiring Example 2
Red
Black
Green/White
Purple/White
Yellow
White
Blue/White
Output for
Lock 2
(Volt-free)
N.O
COM
N.C
Speaker connection
for ‘door bell’ facility
(80.5w recommended)
Input DC: +12V - +24V
Input AC: 12V - 24V
or
+
_
Grey
Orange
Pink
Push button
for Lock 1
(N.O)
P.b for Lock 2
(N.O)
Green
Purple
Blue
Output for
Lock 1
(Volt-free)
N.O
COM
N.C
Lock -release time
N.C for
Electro-magnetic lock
N.O for
Electronic lock
Capacitor for
Electro-magnetic lock
Diode for
Electronic Lock
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 5

6
ess Pin Numbercc-up Aow to setH
ctionA
Number
tepS
9
02
????
##
6
5
4
3
2
1
ogrammingo end prT
t be used)(1234 no
ter a 4 digit pinEn
000
9
location number
ter a startingEn
ogrammingPr
terEn
(Default)
123412
Indication
ypadeK
one
T
To
ongL
34
e
one
T
To
ongL
one
T
To
ongL
one
T
To
Doubl
e
9
99
ags
ess T
Ta
ccA-upow to setH
ctionA
Number
tepS
9
05
1
5
4
3
2
???
0009
location number*
ter a unusedEn
edegistertags to be r
ter number ofEn
ogrammingPr
terEn
(Default)
12341
Indication
ypadeK
oneT
ongL
234
oneT
ongL
one
T
To
oneT
ongL
99
##
6
7ogrammingpr
o end
T
To
one
T
To
*Each tag will use up a location number
egisterwill auto r
ther batch tagsAll o
est serial numberwlo
t the tag with theesenPr
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 6

7
ag
ess Pin or T
Ta
ccDeleting A
ctionA
Number
tepS
1
4
3
20009
pinnumber of tag/
ter the locationEn
ogrammingPr
terEn
(Default)
12341
te
o dele
T
To
## ogramming
o end pr
T
To
Indication
ypadeK
oneT
ongL
99
234
ogramming PinChanging Pr
ctionA
Number
tepS
3
##
5
4
3
2
1ogrammingPr
terEn
ogramming
o end pr
T
To
???? ogramming pinpr
w 4 digitter neEn
???? ogramming pinpr
w 4 diter nee-enR
(Default)
12341
Indication
ypadeK
one
T
To
ongL
234
oneT
ongL
git
eed in twicterode is enogramming cpr
ogramming mode, the 4 digits prypad’eess kco acte; ToN
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 7

8
ag Data
Clear all Pin and T
Ta
ctionA
Number
tepS
8
88
##
ogrammingPr
terEn
ogramming
o end pr
T
o
4
3
2
1(Default)
12341
2
Indication
ypadeK
one
T
To
ongL
2
34
one
T
To
ongL
actory SettingsDefault to F
ctionA
Number
tepS
8
99
##
ogrammingPr
terEn
ogramming
o end pr
T
o
4
3
2
1(Default)
12341
Indication
ypadeK
one
T
To
ongL
234
one
T
To
ongL
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 8

9
Lock 1 Output Operating Time
ctionA
Number
tepS
1
##
onds 00-99of sec
ter numberEn
ogrammingPr
terEn
ogramming
o end pr
T
To
4
3
2
1
??
(Default)
12341
2
Indication
ypadeK
one
T
To
ongL
2
34
one
T
To
ongL
acilityEnable ‘Door Bell’ F
ctionA
Number
tepS
2
##
ogrammingPr
terEn
ogramming
o end pr
T
To
4
3
2
1
02
o enable
T
o
door bell’ push in normal modeomes the ‘Bec
(Default)
12341
2
0 1
T
Indication
ypadeK
one
T
To
ongL
2
34
one
T
To
ongL
o disable
T
To
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 9

10
’ facilityamper AlarmEnable ‘T
ctionA
Number
tepS
6
##
ogrammingPr
terEn
ogramming
o end pr
T
To
4
3
2
1
02
xposedt sensor is edoor bell’ output if the ligh‘
er andternal buzzs inypad’eates the kamper alarm activT
o enable
T
o
(Default)
12341
2
0 1
o
T
To
Indication
ypadeK
one
T
To
ongL
2
34
e
one
T
To
ongL
o
disable
or Lock 2 Outpu
t
ess Pin Number fccA
ctionA
Number
tepS
9
03
????
5
4
3
2
1
t be used)(1234 should no
ter a 4 digit pinEn
00
location number
ter an unusedEn
ogrammingPr
terEn
(Default)
123412
0
9
t
Indication
ypadeK
one
T
To
ongL
34
one
T
To
ongL
one
T
To
ongL
one
T
To
Doubl
e
9
##
6ogrammingo end prT
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 10

11
or Lock 2ess Pin fccDeleting A
ctionA
Number
tepS
1ogrammingPr
terEn
number of pin
ter the locationEn
4
3
2
(Default)
12341
te
o dele
T
To
## ogramming
o end pr
T
To
00
0
4
5
Indication
ypadeK
234
one
T
To
ongL
0
9
or Loc
k
Lock Output Operating Time f
ctionA
Number
tepS
5
##
onds 00-99of sec
ter numberEn
ogrammingPr
terEn
ogramming
o end pr
T
To
4
3
2
1
??
(Default)
12341
2
k
2 Output
Indication
ypadeK
one
T
To
ongL
2
34
one
T
To
ongL
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 11

12
To assist in future programming, it is recommended that a
record is made of the system setup.
System Location Tag Serial Tag Owner Notes
Number (000-999) Number
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 12

13
System Location Tag Serial Tag Owner Notes
Number (000-999) Number
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 13

14
ed tagegisterr
t aesenPr
(B)
ess Pin numberccA
ogrammedter a prEn
(A)
ock 1elease L
or
T
To
T
ogramming modeess prc
oac
T
To
(Default)
12341234
User Guide
Technical Specification
DC input 12 - 24volts
AC input 12 - 24volts
Standby current 80ma
Operating current (without lock) 110ma
Working temperature -20c to +50c
Reader frequency 125KHz
IP rating 65
Dimension 150 x 44 x 24mm
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 14

15
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 15

www.espuk.com
Elite Security Products
Unit 7, Target Park, Shawbank Rd
Lakeside, Redditch B98 8YN
Telephone: 01527 51 51 50
Fax: 01527 51 51 43
email: [email protected]
E&OE - Errors and omissions excepted. L15
EZTAG3 Manual.qxp_Layout 1 04/01/2016 11:47 Page 16
This manual suits for next models
1
Table of contents
Other ESP Door Lock manuals
Popular Door Lock manuals by other brands

Assa Abloy
Assa Abloy NORTON RIXSON M19 installation instructions

Dorex
Dorex F425T user guide

Cal-Royal
Cal-Royal CRCODE-203 Instruction and programming manual

Command access
Command access CL180 installation instructions

LOCKEY USA
LOCKEY USA 1150 installation instructions

Kaba
Kaba 7102 series installation instructions