Month Test
Sign Date Sign Date Sign Date Sign Date Sign Date
1 Functional
2 Functional
3 Functional
4 Functional
5 Functional
6 1 hour
7 Functional
8 Functional
9 Functional
10 Functional
11 Functional
12 3 Hour
1st year 2nd Year 3rd Year 4th Year 5th year
LuminaireType/Ref: Date of Installation: Location:
TEST RECORD SHEET
Rated input supply: AC 240V 50Hz
Rated output power: 8 x SMD 2835 LED
Operating Environmental: Temperature:- 0-40 °C
Operating relative humidity: Less than 90%
Emergency Duration: More than 3 Hours.
Change over time: Less than 1 second.
EMDLED3WMBULK2
3W LED IP65 Maintained Emergency Bulkhead
GENERAL INFORMATION
Our products are designed to comply with the recommended codes of practice
for emergency lighting of premises and be installed by competent person in
accordance with the relevant wiring regulations.
LUMINAIRE INFORMATION
Battery Specification: 3.6v 1200mAh NI-CAD Batteries
MONITORING
Green indicator lamp (LED) normally continuously ‘on’. Indicator lamp goes
out if A.C. supply or charger fails.
For additional product information please visit the ESP website
www.espuk.com/technical_support/product_manuals/?cat=5
K19
IP65
WARNING
• This product must be disconnected from the circuit if subjected to any high
voltage or insulation resistance testing. Irreparable damage will occur if this
instruction is not followed
• Recommended routine test procedure in accordance with BS 5266
• Daily check - check that the status GREEN LED indicator is illuminated
• Monthly functional test - simulate a mains supply failure for approx. 30 secs by
operation of a key switch or circuit breaker.Ensure normal supply
is restored after test and the indicator status LED is illuminated.
• Twice yearly conduct a one hour duration test - simulate a mains supply failure
breaker. Ensure normal supply is restored after test and the indicator status LED
is illuminated
• Annual full three hour duration test - conduct a three hour continuous
duration test. Simulate a mains supply failure for three hour continuous test by
r. Ensure normal supply is
restored after test and the indicator status LED is illuminated
•
GENERAL
the correct manner when it reaches the end of its life. Check local authorities for
where facilities exist. Clean with a soft dry cloth only , do not use aggressive cleaning
GENERAL INSTRUCTIONS
These instructions should be read carefully and retained after installation by the end
user for future reference and maintenance.
SAFETY
•
or competent person to the current IEE Wiring Regulations
• Please isolate mains prior to installation/maintenance
•
not exceed the rating of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress of Protection) rating of this luminaire when deciding
the location for installation
electrician. See overleaf for test record sheet
INSTALLATION
• Provide power to the required point of installation. Suitable IP rated junctions
boxes should be used where required
•
with any joists, gas or water pipes or electrical cables
• For non-maintained operation please wire up connector block as shown in Fig 3
• For maintained operation (luminaire always on) please see Fig 4
• For switchable maintained operation
see Fig 5
• Connect the battery via the plug and
socket on the PCB
• Switch on the power supply and ensure
the LED indicator is illuminated Green
• Remove two screws
• Pull apart tabs (see Fig 2) to
gain access to the connections
Fig 1 Fig 2
Fig 3
Fig 4
Fig 5
Insert link
cable
Remove screws Pull apart tabs
• Switch on the power supply and ensure the LED indicator is illuminated green. If it is not
illuminated green, there may be a supply or battery fault

Other ESP Safety Equipment manuals

ESP ExB Series User manual

ESP

ESP ExB Series User manual

ESP Duceri EMLED5WMBULK User manual

ESP

ESP Duceri EMLED5WMBULK User manual

Popular Safety Equipment manuals by other brands

Salewa Dyneema user manual

Salewa

Salewa Dyneema user manual

Highnovate BELLA Instructions for use

Highnovate

Highnovate BELLA Instructions for use

Scissorsafe SCS003 User instructions

Scissorsafe

Scissorsafe SCS003 User instructions

E2S IS-CP4A-BG instruction manual

E2S

E2S IS-CP4A-BG instruction manual

IKAR HRA Series Instructions for the use and inspection records

IKAR

IKAR HRA Series Instructions for the use and inspection records

Stanley DE-MC521 Quick reference guide

Stanley

Stanley DE-MC521 Quick reference guide

SKYLOTEC RIDER 3.0 Instructions for use

SKYLOTEC

SKYLOTEC RIDER 3.0 Instructions for use

MEDC SM87BG Technical manual

MEDC

MEDC SM87BG Technical manual

Nammo IKAROS 346100 instructions

Nammo

Nammo IKAROS 346100 instructions

Spencer STX 518 Use and maintenance manual

Spencer

Spencer STX 518 Use and maintenance manual

Guide 402 Instructions of use

Guide

Guide 402 Instructions of use

Thiele Grade 100 operating instructions

Thiele

Thiele Grade 100 operating instructions

Positron Teleline 751109/15 Description and installation

Positron

Positron Teleline 751109/15 Description and installation

SKYLOTEC MAT-BA-0130 User instruction manual

SKYLOTEC

SKYLOTEC MAT-BA-0130 User instruction manual

Singing rock HEX Instructions for use

Singing rock

Singing rock HEX Instructions for use

Leatt Z FRAME JNR Adjustment

Leatt

Leatt Z FRAME JNR Adjustment

Syntech MAXAIR CAPR 2272PB-100 User instructions

Syntech

Syntech MAXAIR CAPR 2272PB-100 User instructions

AUSTRIALPIN COMPACT manual

AUSTRIALPIN

AUSTRIALPIN COMPACT manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.