AP-40User Manual
Noise (measured, 1 m / 90 °)
Level 1: 35 dB
Level 2: 37 dB
Level 3: 48 dB
Level 4: 51 dB
Technical Data AP-40
Aerea 40 m²
Clean Air Delivery Rate 320 m³/h
Voltage 110 V / 230 V
Frequency 50 Hz or 60Hz
Rated Power 60 W
Dimensions (mm) 620 x 391 x 227
Net Weight (kg) 8,5 kg
Ambient temperature 5 °C – 40 °C
Relative humidity < 80%
Ozone concentration < 0,005 mg/m³
Automatic Mode yes
Remote Control IR
Operation Touch
Air Quality Display Colorchange
Sensor PM2.5
Pre Filter yes
HEPA Filter (medical grade) H13 PP+PET
Activated Carbon Filter honeycomb
TIO2 Titanium Dioxide Filter yes (pholtocatalytic oxidation)
UV-C Sterilizing Lamp yes (pholtocatalytic oxidation)
Plasma
yes (bi-polar)
Certification /Reports
CE, ROHS, FCC, official biological
and filter function report of GDIM
Viruses / Bacteria tested
(Details see Report)
H1N1 + H3N2 + 5 Bacteria
Filter test PM2.5 / PM0.3
UV & Filter Change Indicator yes (after approx. 8000 h)

www.ets-products.com
3
AP-40User Manual
The voltage and frequency depend on the standard of the country or region in which the
devices are intended of being used. The device data can be found on the product label. Use
only devices that are suitable for your region.
Packing List
Air Purifier 1
Power Cord 1
User Manual 1
Remote Control 1

www.ets-products.com
4
AP-40User Manual
Features:
The device is equipped with a highly efficient filtration and cleaning system, including HEPA
H13 filter, activated carbon filter with high iodine content, TIO2 photocatalyst filter, plasma
and UV sterilization lamp with a wave length of 254 nm. It can remove PM 2.5,
formaldehyde, benzene, ammonia, TVOC, dioxide, sulfur, odors, smoke, dust, etc. from the
air and effectively removes bacteria and viruses.
Socket
Power socket

www.ets-products.com
5
AP-40User Manual
Pre-use Preparation
1.Placethedevicehorizontallyupright
2.Pleasemakesurethattherearcase coveristightlyclosed.
3.Insert the power plug into the back of the device as shown.
4.After connecting to the power grid, you will hear a beep indicating that the device is in
Standby Mode. The standby indicator is on.

www.ets-products.com
6
AP-40User Manual
Intelligent Automatic Mode (recommended use mode)
Press the power button , the main air duct is opened
and the symbol will be displayed. By default,
the purifier is in the Intelligent Automatic Mode, thus
the purifier will automatically adjust its purification
performance based on the currentairquality.
Air Quality Sensor
The air purifier has a highly sensitive air dust sensor. In milliseconds, the sensor gives the
purifier a command to adjust the purification performance in real-time based on the current
air quality.
Air Quality Indicator Lamp
The air quality indicator has three levels: good (blue) / average (green) / bad (red). Except in
sleep mode, the air quality indicator lights up continuouslyon to display the indoor air quality
inreal-time.
good (blue) average (green) bad (red)

www.ets-products.com
7
AP-40User Manual
Manual Adjustment of Purification Level
The air purification level can be set manually in 4 levels as required: quiet,low,middle,
high.The airqualitysensorcontinuesto work and is notaffected by the respective setting.
Removal of Formaldehyde and Sterilization
The device is equipped with a special nano photocatalytic filter and UV sterilization
system. This function is not activated at the first start. It can be activated manually by
touchingthesymbol .Repeated touchdeactivatesthe function again.

www.ets-products.com
8
AP-40User Manual
Timer
Sleep Mode
By pressing the timer button you can pre-set the operating
timeto 1h, 4h, 8h, 12h and 24h or activate the stand-by mode.
Press repeatedly to choose the desired setting.
By activating the sleep mode, all indicator lights are switched off, the cover of the
main air duct is closed and the cleaning cycle is now diverted to the front air duct,
thus creating a comfortable and quiet environment for your sleep.
Press or or the air flow adjustment button to leave the sleep mode.

www.ets-products.com
9
AP-40User Manual
Child Safety Lock
By pressing the button, the control panel will be locked. The device, in this
mode, can no longer be set by using the control panel. Press againtounlock
the control panel.
Multi-Layer Air Filter
Pre-Filter
HEPA-Filter
Activated Carbon-Filter
Photocatalytic Nano Filter

www.ets-products.com
10
AP-40User Manual
Remote Control
(Note: Our products are updated irregularly, the layout of the remote control may
vary)
Routine Maintenance - ATTENTION!only proceed when poweris disconnected
1. Primary dust collector: Use both hands to press down the latch, open the back cover,
take outthedust filter,and use a vacuumcleanerto removethesurfacedust.Then putit back
inthe deviceandkeepusingit.
2. Photocatalytic Nano Filter: This filter can be cleaned regularly using a vacuum
cleanertoremovesurfacedust.Itcancontinue tobeusedafter cleaning.
3. Dust cover of the dust sensor: Remove the dust cover of the dust sensor, gently wipe it
witha brush ordry cloth and blowoffthe dust. (Caution:donotuseanyliquidforcleaning!)
On/Off
Manual Mode
UV Sterilisation
Automatic Mode
(intelligent Air Purification)
Confirm HEPA Filter Replacement
(press 5 seconds)
Sleep/Night Mode
(quiet operation)
Confirm UV-Lamp Replacement
(press 5 seconds)

www.ets-products.com
10
4.HEPAfilter: Theair purifiersavestheusagetimeand remindsyoutoreplacethefilter.
If flashes with multiple beeps, the HEPA filter must be replaced. Please replace
immediately.
Reset timer: Press the "HEPAReset" button and hold it downfor5 secondsafter changing the
filter.Along beepindicates thatthetimerhas been reset.
5.UVlamp: theair purifier saves the usagetimeandremindsyoutoreplace the bulb.
If flashes with multiple beeps, the UV bulb must be replaced. Please inform customer
service.
AP-40User Manual
HEPA-Filter Replacement
Indicator
UV-Bulb Replacement
Indicator

AP-40User Manual
www.ets-products.ph
11
Important Safety Instructions
Beforeuse, the rearcover ofthe housing must becompletely closed.
Donot open therear cover oftheunit during use.
Before connecting the device to the power grid, check that the voltage and frequency
indicated on the product label matchesthevoltage and frequency usedin your region.
Iftheplug,powercord or caseis damaged, donotuse theproduct.
Keepchildrenawayfromtheproduct.
Donot block theair inlets andoutlets.
Theproduct is suitable fordryrooms only.
Clean the housing with a dry or slightly damp cloth. Never use alcohol-based cleaning
agents to wipethehousing!

AP-40User Manual
www.ets-products.ph
12
ETS Products Philippines Inc.
Berthaphil IV Warehouse 2C,
Civil Aviation Complex,
Clark Freeport Zone,
Pampanga 2023, Philippines
Contact (Asia) Contact (Europe)
Phone: +63 (0)45 499 5607
Email: inquiry@ets-products.ph
Phone: +49 2204 9673 650
Email:
europe@ets-products.com
Table of contents
Other ETS Air Cleaner manuals