Eurogauge LAS31Z1 User manual

1/4
Declaration of Conformity
LAS Series Level Alarm System
This is to certify that the above named product(s) fully complies with the
ElectromagneticCompatabilityDirective89/336/EECandtheLowVoltageDirective
73/23/EEC of the European Union and with the requirements of the normative
sections of the following harmonised European Standards.
EN61000-6-3: Electromagnetic Compatibility - Generic Emission Standard.
Residential, Commercial and Light Industry.
EN61000-6-1: Electromagnetic Compatibility - Generic Immunity Standard.
Residential, Commercial and Light Industry.
EN 61010-1: Safety requirements for electrical equipment for measurement,
control and laboratory use.
Signed :
D. C Ward
Position: Technical Services Manager
Date: 12/12/2005
This declaration applies to the following part number(s):
LAS31Z1: LAS 3 85-265Vac/24Vdc version.
LAS33Z1: LAS 3 9V Battery Version.
4/4
Specification
Supply:
85 to 265Vac; 50/60Hz; 4VA, +24Vdc
Indicators:
Tank Full - Red
Tank Empty - Red
Bund Full - Red
Power - Amber
Controls:
Test Button simulates alarm conditions
Mute Button mutes alarm sounder
Relays: SPCO 250V; 3A non-inductive load. de-energises upon
alarm – remains de-energised until alarm clears
Sounder: Internal piezo-electric sounder (90db @ 0.6metre)
Sensor:
Floatswitch x 3, 5m cable with 1” BSP tank connector
Housing: Polycarbonate ABS enclosure
Dimensions: 176mm x 125mm x 76mm
Protection: IP65
Cable Entry: 5 Pg11 glands for 6-8mm cable
Weight: 0.60kg
LAS31Z1 - AC/DC Version
Battery:
+9V PP3 Alkaline 6 LR 61, 6 AM 6, MN 1604
Indicators:
Tank Full - Red
Tank Empty - Red
Bund Full - Red
Controls:
Test Button simulates alarm conditions
Mute Button mutes alarm sounder
Sounder: Internal piezo-electric sounder (90db @ 0.6metre)
Sensor:
Floatswitch x 3, 5m cable with 1” BSP tank connector
Housing: Polycarbonate ABS enclosure
Dimensions: 176mm x 125mm x 76mm
Protection: IP65
Cable Entry: 5 Pg11 glands for 6-8mm cable
Weight: 0.60kg
Note: We reserve the right to amend these specifications without prior notice.
LAS33Z1 - Battery Version
Tank Full
Alarm Point
Tank Empty
Alarm Point
Bund Full
Alarm Point
Tank
FillPoint
LAS Unit - Battery
or AC/DC Version
EUROGAUGE
...the level people User Guide
LAS LevelAlarm System
EUROGAUGE
...the level people
User Guide
LAS LevelAlarm System
· RADAR and MICROPULSE
· ULTRASONICS
· PRESSURETRANSMITTERS
· VIBRATIONSWITCHES
· CAPACITANCE
·Float Level Switches
· Conductivity
· Rotary Paddle
· Magnetostrictive
· Self-poweredgauges
· Oil/water Alarms
· Leak Detectors
· Pressure and Temperature
The LAS3 Alarm providesTank Full, Tank Empty and Bund Full audible and visual alarms for oil storage tanks.
The LAS31Z1 is powered from a 85 to 265Vac or 24Vdc supply and the LAS33Z1 from a 9V replaceable battery.
Simple floatswitches mounted in the tank and bund area are used to provide the alarm signals.
The LAS31Z1 provides a continuous display of alarm conditions while the LAS33Z1 is powered on by an alarm
signal or whenever the Test button is pressed. Once the LAS33Z1 has been powered on by an alarm signal the
corresponding alarm lamp lights and the sounder operates. If the alarm is not acknowledged by pressing the
Mute button the unit will sleep after 5 minutes and will wake every hour operating the sounder for 5 seconds and
thealarm lampfor 10seconds.This continues until the alarm condition is cleared or until the battery is exhausted
(around 240hrs with a new battery). Acknowledging the alarm immediately turns the sounder off and the alarm
lamp off after 30 seconds and puts the LAS33Z1 into sleep mode. When there are no alarms present the
LAS33Z1 is switched off.
On pressing the Test button all alarm lamps light and the sounder operates, releasing the Test button turns
the alarms off. Any existing alarms will be displayed for 30 seconds before turning off.
LAS3 Typical Installation
A Flameproof version (EEX D) is available to order, please contactAfriso Eurogauge Ltd for further details.
WARNING: NOT FOR USE ON LIQUIDS IN STORED WITHIN HAZARDOUS AREAS
Unit 4, Satellite Business Village
Fleming Way, Crawley
West Sussex. RH10 9NE
Tel: +44 (0)1293 658360
Fax: +44 (0)1293 528270
www.eurogauge.co.uk

EUROGAUGE
...the level people
User Guide
LAS Level Alarm System
2/4
Installation & Electrical Connections
The alarm unit is designed for
four-screw wall mounting on a
160mm x 110mm pitch.
It is recommended that the unit
isnotmountedin a location where
it is exposed to direct sunlight.
Allwiringmustbeinsuitablecable
for the site conditions.
Theinstallationmustcomplywith
the relevant regulations of the
electrical supply authority
concernedtogetherwithanyother
statutoryrequirementswhichmay
affect the complete installation.
3/4
Float Switch Installation
Pass the float switch lead through the tank/cable
glandassemblytogivethedesiredalarmswitchpoint
and tighten the cable gland.
Fit the float switch assembly through the 1" BSP
tank gland in the tank.
Should the float switch lead require extension, fit a
PVKA extension cable connector to the float switch
lead and run the length of additional cable from the
PKVAconnector to the TA3 unit.
Dimensions
PKVA
Extension
Cable
Connector
Extension
Cable
(2 Core)
supplied
by
Installer
Weight
Cable Gland
Adjust Cable
Gland to set
Alarm Point
LAS 3
Alarm Unit
Float
Circlip
Turn Float
upside down
for Low
Level Alarm
(remove
Circlip
to alter)
Float Switch Assembly
EUROGAUGE
...the level people User Guide
LAS LevelAlarm System
175
76
125
Fixing centres:- 160 x 110mm
24Vdc or 85-265Vac Version
Battery Version
Tank Full
Float Switch
Tank Empty
Float Switch
Bund Full
Float Switch
IP1 IP2 IP3
IP1 IP2 IP3
Tank Full
Float Switch
Tank Empty
Float Switch
Bund Full
Float Switch
Live
Neutral
Earth
+24Vdc
0V
Closed when Tank Full
Common
Open when Tank Full
Closed when Bund Full
Common
‘All Alarm contacts are voltage free’
Closed when Tank Empty
Common
Open when Tank
Empty
Tank Full
Alarm
Contacts
Bund Full
Alarm
Contacts
Open when Bund Full
Tank Empty
Alarm
Contacts
This manual suits for next models
1