3
DTP T HWP/UWP 232/332 D • Setup Guide (Continued)
D DTP OUT connector — Connect one end of a twisted pair cable to this RJ-45 connector and the opposite
end to a compatible receiver.
ATTENTION:
• Do not connect these outputs to a telecommunications or computer data network.
• Ne connectez pas ces appareils à des données informatiques ou à un réseau de
télécommunications.
NOTES:
• The DTP T HWP/UWP 232 D models can transmit video, control, and audio (if applicable)
signals up to 230 feet (70 meters).
• The DTP T HWP/UWP 332 D models can transmit video, control, and audio (if applicable)
signals up to 330 feet (100 meters).
E Reset button — Use an Extron Tweeker or small screwdriver to press and hold the recessed button for 6 seconds while
the switcher is running to perform a factory reset.
Step 4 — Run Cables Between Units
Connect the rear panel transmitter output to a rear panel receiver input using twisted pair cable.
Wire the cable as shown in the diagram to the right.
For optimal performance, Extron highly recommends the following:
zRJ-45 termination with shielded twisted pair cable must comply with TIA/EIA-T568B wiring
standard for all connections.
For more information on TP cable wiring and termination, see the full product user guides at
www.extron.com.
zUse shielded twisted pair cable, 24 AWG solid conductor or better, with a minimum cable
bandwidth of 400 MHz.
ATTENTION:
• Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 cable to link the device with
DTP transmitters or receivers.
• N’utilisez pas le câble AV Skew-FreeUTP version améliorée UTP23SF d’Extron ou le câble STP201 pour relier
le appareil avec les émetteurs ou les récepteurs DTP.
zUse shielded RJ-45 plugs to terminate the cable.
zLimit the use of RJ-45 patches. Overall transmission distance capabilities vary depending on the number of patches
used. If possible, limit the number of patches to two total.
zIf RJ-45 patches must be used in the system, shielded patches are recommended.
Step 5 — Connect the Outputs from a Compatible Receiver
a. Connect a DVI or HDMI cable (depending on your receiver type) between the receiver output port and the input port of
the display.
b. Connect a stereo audio device to the 3.5 mm mini stereo jack to receive the passed-through unbalanced audio.
c. Plug an RS-232 or modulated IR device into the RS-232/IR pass-through port.
Step 6 — Power the Units
The units can be powered one of two ways:
zLocally with the included power supply. A compatible receiver can then be powered remotely through the DTP line.
zRemotely via the DTP line by a locally powered DTP 230 or 330 compatible device.
NOTE: See the DTP T HWP/UWP 232/332 D User Guide at www.extron.com for wiring information.
5
Pin
1
2
3
6
7
8
4
Wire color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
Blue
TIA/EIA
T568-B
12345678
SIG LINK
DTP OUT