ELECTRICAL WIRING DIAGRAM OF THE ELECTRONIC
PROGRAMMER
Once the connections have been made, do the first switching
test through the control panel. Set the motor run timer so that
the motor is allowed to run 4 - 5 seconds more than the gates.
Set the other timers to meet the site requirements. Set DIP
switch B No. 3 to automatic (ON): on pulsing to 4 - 8 the gates
must be operated as pre-set, ie. opening and only after the
dwell time, closing. Adjust the times through the respective
timers. (See No. 07, 08 and 09 drwg. No. 1643).
With DIP switch "B" No. 3 to semiautomatic (OFF) one pulse
opens the gates, a second pulse to 5 - 9 is needed to close
the gates. Any one pulse to 7 - 8 will open, close or reverse
the gates independently from the operation being performed.
It is recommended to carefully read the instructions in the
control box to have all the functions performed correctly.
The 6 LEDs on the P.C. board indicate the following:
Led No. 1 It switches on when voltage is supplied
Led No. 2 Photocells - Normally on. It switches off when the
photocells are obstructed
Led No. 3 Open - It switches on when the respective switch
is activated
Led No. 4 Close - It switches on when the respective switch
it activated
Led No. 5 Stop - Normally on. It switches off when the
respective switch is activated
Led No. 6 Radio - It switches on whenever a pulse is given,
either from remote control, keyswitch or push
buttons.
P.C. BOARD
CONNECTION DIAGRAM FOR SWING GATES
12345 6789
10 11 12 13 14 15 16 17 18
7 8
M1 M2
19 20 21 22 23 24 25
12,5+F12,5+F
123456
7
8
9
–
ON
OFF
1 2 3 4 5 6 7 8
ON
RADIO CONTROL
PLUG-IN CARD SUPPORT ON TO “0” THE DELAY
IS OUT OF SERVICE
DWELL TIME
MOTOR RUN
OPEN & CLOSE TIME
CAPACITORS
MICROPROCESSOR
DIP-SWITCH
TERMINAL FOR
CONNECTIONS TO
PUSH BUTTONS PULIN 3
1 AMP. FUSE
24 V OUTPUT
TERMINALS 12-13
TIMER SWITCHES
FUSE
630 mA
FUSE 5 AMPS
1st CHANNEL
24 V OUTPUT
Should more pairs of photocells be required
than the recommended quantity, fit an auxiliary
transformer outside the control box.
= PHOTOCELLS 2nd PAIR =
Inside photocells N.C. contact
If obstructed they prevent the gates from opening
reverse gate direction during close cycle
N.C. CONTACT
PHOTOCELLS
COMMON
OPEN SWITCH N.O. CONTACT
CLOSE SWITCH N.O. CONTACT
STOP SWITCH N.C. CONTACT
RADIO CONTACT N.O.
COMMON
VOLTAGE OUTPUT
ELECTRIC LOCK SUPPLY
24 V INDICATOR - 3 W max.
24 V
OUTPUT A.C.
Max permitted load:
2 pairs photocells
1 radio receiver
COMMON
COMMON
230 V FLASHING LAMP
25 W max.
230 V SINGLE-PHASE
SUPPLY VOLTAGE
ELECTRIC MOTORS
SINGLE-PHASE
NOTE WELL: For special applications, ie. to switch on lights -
CCTV etc., SOLID STATE RELAYS are recommended to be used
only. Standard relays would affect the micro-processor.
ALL OPERATIONS
OPEN, CLOSE AND
REVERSE
RADIO CONTACT
LEAF DELAY
TIMER CLOSE
LED No. 1 - It switches on when voltage is supplied
OPEN
STOP
CLOSE
N.O. N.C. N.O.
3
45 6
26 27 28 3
CONNECTION TO THE “PULIN 3” PUSH
BUTTONS WITH STATUS INDICATION LEDS.
0
FLASHING LAMP
630 mA FUSE
SAFETY CONTACT N.C.
3 4
NOTE WELL: THIS PANEL IS TESTED TO OPERATE GATES ONLY
THROUGH FADINI ACCESSORIES. NO WARRANTY IS
ACKNOWLEDGED BY THE MANUFACTURER IN CASE THAT
OTHER ACCESSORIES ARE USED OR NON CONFORMING
APPLICATIONS ARE MADE WITHOUT THE MANUFACTURER’S
APPROVAL.
+
+
+
26
27
28
PEDESTRIAN MODE
ONE PULSE OPENS
ONE GATE LEAF ONLY
PULSE TWICE CONSECUTIVELY
TO OPEN BOTH GATE LEAFS
I