FAMILY INADA HCP-LPN-30000A User manual

68
O
♥
BPM
68
O
♥
BPM
Foot rest mounting screw
×2
Active measure (2 pieces)
Installation manual
(this document)
Tablet
Foot rest connector cover
Foot rest
Main machine
Arm rests x 2
(right and left)
Push turn rivet for mounting
foot rest connector cover
T-shaped wrench Power cable
To those who conduct unpackaging and installation work
Check of bundled items
Installation Manual
This document explains the work to be carried out after carrying-in of the product for installation. To work
safely and accurately, be sure to follow the steps in this document. The box containing this document
also contains the objects shown below. Confirm that none of them are missing. After installing the prod-
uct, keep this manual safe and available for future reference.
Confirm that the following items are contained in the package.
This product comes as two package boxes: one for the main machine and tablet and the other for the
foot rest and arm rests.
Confirm that the main machine and bundled items are not damaged or broken.
1
12
22
Main machine
Foot rest and
arm rests
Bundled items
HCP-LPN-30000A
HCP-LPN-30000D
HCP-LPN-30000E

Installation steps
Installation location
Install this product by following the steps below.
In order to prevent the product from making contact with a wall or other object, secure a clearance of 65 cm (25.6 inch) or
more behind the product and a clearance of 30 cm (11.8 inch)or more in front of the product.
1. Check the installation location and carry in the product.
2. Mount the arm rests. 3. Attach the tablet.
4. Attach the power cable. 5. Mount the foot rest.
●This product is heavy. Therefore, wear working gloves to prevent injury.
●Installation of this product must be carried out by two or more persons.
●When a product has been carried into a room from the cold outdoors, wait until the product has warmed up to room temperature (for one
hour or longer) before staring the installation work.
●To prevent the floor surface from being damaged and to reduce the sound made during work, place a mat or the like beneath the product.
(Do not place a hot carpet.)
●This product is heavy. Therefore, pay attention not to damage the floor surface when putting down the product.
●Keep this product at least one meter away from AV devices such as a TV set or radio. Failure to follow this instruction may cause noise to interfere with
the product.
●When a person weighing 100 kg (220 lbs.)sits on the product, a load of about 1.9 kg/ ㎠is applied to the floor surface.
●Do not use this product in a humid location such as bath room or sauna.
●Install and use the product on a level floor surface.
●+VUV[\ZL[OLWYVK\J[PU H K\Z[` SVJH[PVU VY H SVJH[PVU ^P[O H OPNO HTIPLU[ [LTWLYH[\YL*ǣVY
higher).
●Do not install the product in a location subject to direct heat radiation, such as direct sunlight or a stove, that
may heat the product to a high temperature.
2
Checking installation location of the product
CAUTION
Approx. 222 cm
(87.4 inch)
Approx. 135 cm
(53.1 inch) Approx. 108 cm
(42.5inch)
Approx.
30 cm
(11.8 inch)
Approx.
37 cm
(14.5 inch)
Approx. 65 cm
(25.6 inch)

How to carry in and relocate product
When relocating the product, turn off the main power switch, disconnect the power plug from the receptacle, and also
disconnect the connector of the power cable from the inlet.
●The passage requires a width of about 70 cm (27.5 inch )or greater.
●As the product is heavy, wear gloves for carrying so as not to drop the product or get injured.
●As the product is heavy, pay attention not to cause lower back pain during carrying in and transfer.
●Dropping this product may damage the floor or injure you. Therefore, securely hold the product.
●Do not carry the product with a person sitting on it.
●Before transferring the product, disconnect the power cable from the receptacle, and disconnect the power
cable connector from the inlet.
→Failure to follow this instruction may damage the power cable , possibly causing fire or electric shock.
3
Relocating the product after its installation
To carry the product, one person should hold the hook at the rear side of the back rest, and the other person should hold
the lower front part of the main machine.
Carry the product using two people
CAUTION
The weight of the main machine is about 77 kg(170 lbs.). Therefore, move it very carefully.
Two people should hold the back rest and the lower front part of the main machine.
The total weight of the right and left arm rests is about 17 kg (34.5 lbs.).
The weight of the foot rest is about 23 kg(50.7 lbs.).


Dismounting side panels
5
Check the positions of the six claws
on the side panel that is bundled in
the package, and attach it on the
arm rest while confirming the click-
ing sound.
❽Follow the same steps for the opposite side.
(Although the figure illustrates the right side,
also work in the same way for the left side.)
CAUTION
Positions of
claws at the back
Insert a flat-blade screwdriver into
clearances from the side panel.
To the recesses at these locations,
insert a flat-blade screwdriver
from the hole from the back.
Rear face of right side panel
To dismount the side panel and arm rest, follow the above steps in the reverse order.
Claw on side panel
Side panel
Claw on arm rest
Right arm rest
●
Side panel ←Recess for insertion
(clearance)
Insert a thin
flat-blade screwdriver.
●When dismounting a side panel, insert a thin flat-blade screwdriver or the like that you possess into the recesses for
insertion (clearances) between the side panel and the arm rest, depress the claw, and pull the side panel toward you
to dismount it.
Do not forcefully remove the side panel because any attempt to do so may cause the side panel to be broken or you
to get injured.
By disengaging the claws in order from the one at the back of the chair body, it is possible to smoothly dismount the
side panel. ●Before dismounting and mounting the arm rests, confirm that the main power switch is turned “OFF,” and
then disconnect the power cable from the receptacle, and also disconnect the connector of the power
cable from the inlet.
→Failure to follow this instruction may damage the power cable, possibly causing fire or electric shock.
●When dismounting and mounting the arm rests, pay attention not to have your hand or finger pinched
between the main machine and arm rest.
●
During mounting work, positively insert the connector all the way to the back. Securely tighten the mounting
screws as well.
→Failure to follow this instruction may cause a failure.
●As the product is heavy, wear work gloves so as not to get injured.
●Although the figure illustrates the right side, also work in the same way for the left side.
●To dismount the side panel and arm rest, follow the above steps in the reverse order.