manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. F&F
  6. •
  7. Measuring Instrument
  8. •
  9. F&F WNC-3 User manual

F&F WNC-3 User manual

Other F&F Measuring Instrument manuals

F&F DMM-5T-3 User manual

F&F

F&F DMM-5T-3 User manual

F&F ZI-14 User manual

F&F

F&F ZI-14 User manual

F&F LE-01MR v2 User manual

F&F

F&F LE-01MR v2 User manual

F&F LE-03MQ User manual

F&F

F&F LE-03MQ User manual

F&F LE-03MQ User manual

F&F

F&F LE-03MQ User manual

F&F OM-633 User manual

F&F

F&F OM-633 User manual

F&F LE-02d CT User manual

F&F

F&F LE-02d CT User manual

F&F CLG-03 User manual

F&F

F&F CLG-03 User manual

F&F WZE-1 User manual

F&F

F&F WZE-1 User manual

F&F LE-03 User manual

F&F

F&F LE-03 User manual

F&F LE-01MR v2 User manual

F&F

F&F LE-01MR v2 User manual

F&F LE-03d User manual

F&F

F&F LE-03d User manual

F&F WN-723S User manual

F&F

F&F WN-723S User manual

F&F LE-03MW User manual

F&F

F&F LE-03MW User manual

F&F WN-711 User manual

F&F

F&F WN-711 User manual

F&F LE-03M CT User manual

F&F

F&F LE-03M CT User manual

F&F LE-01MR User manual

F&F

F&F LE-01MR User manual

F&F LE-03 User manual

F&F

F&F LE-03 User manual

F&F CLI-01 User manual

F&F

F&F CLI-01 User manual

F&F LE-03MP User manual

F&F

F&F LE-03MP User manual

F&F DMA-3 CT TrueRMS User manual

F&F

F&F DMA-3 CT TrueRMS User manual

F&F LE-03MW User manual

F&F

F&F LE-03MW User manual

F&F CLG-03 User manual

F&F

F&F CLG-03 User manual

F&F DMA-1 CT TrueRMS User manual

F&F

F&F DMA-1 CT TrueRMS User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

- 1 -
WNC-3
Voltage indicator
with display, 3-phase
WNC-3 voltage indicator is designed to measure and indicate the
value of 3-phase AC voltage in the range of 80÷500 V AC.
The WNC-3 indicator contains three independent measurement
chains. The measured voltage values are indicated directly in
numerical form on the 3-row, 3-digit LED display. Voltages are
displayed with a resolution of 1 V, measurement is updated five
times per second.
The measured voltage is also used to power the indica-
tor. If the voltage drops below 80 V, the indicator display
may turn off.
Purpose
Functioning
F&F Filipowski sp. j.
Konstantynowska 79/81, 95-200 Pabianice, POLAND
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
www.fif.com.pl; e-mail: [email protected]om.pl
Do not dispose of this device in the trash along with other waste! According to the Law on
Waste, electro coming from households free of charge and can give any amount to up to
that end point of collec� on, as well as to store the occasion of the purchase of new equip-
ment (in accordance with the principle of old-for-new, regardless of brand). Electro thrown
in the trash or abandoned in nature, pose a threat to the environment and human health.
- 2 -
1.Disconnect the power supply.
2.Install the indicator on the rail in the distribution board.
3.Connect the indicator to the source of measured voltage ac-
cording to the diagram.
It is recommended to protect each phase of the indica-
tor with a slow-blow fuses with a rating current of 0.25
or a 3-phase circuit breaker with B characteristics and
rating current of 1 A.
4.Switch on the power supply and verify that the device is wor-
king correctly.
Mounting
- 3 -
Wiring diagram
- 4 -
power supply 80÷500 V AC
frequency 50÷60 Hz
voltage indicator 3× 3-digit, 7-segment LED
digit height 7 mm
measurement resolution 1 V
measurement accuracy 1% (±1 digit)
power consumption <5 VA, <1 W
working temperature -5÷40°C
storage temperature -25÷70°C
terminal 1.5 mm² screw terminals
tightening torque 0.4 Nm
dimensoins 1 module (18 mm)
mounting on TH-35 rail
ingress protection IP20
F&F products are covered by a 24-month warranty from the date
of purchase. The warranty is only valid with proof of purchase.
Contact your dealer or contact us directly.
F&F Filipowski sp. j. declares that the device is in conformity
with the essential requirements of The Low Voltage Directive
(LVD) 2014/35/EU and the Electromagnetic Compatibility (EMC)
Directive 2014/30/UE. The CE Declaration of Conformity, along
with the references to the standards in relation to which con-
formity is declared, can be found www.fif.com.pl on the product
subpage.
Technical data
Warranty
CE declaration
E210208