F&F CLG-03 User manual

PURPOSE
FUNCTIONS
CLG-03 is a programmable, multi-function electronic meter,
enabling the counting of working hours of the connected devices
or systems in 1 to 999 999 range, corresponding to 114 years of
operation. Working time is counted according to an individual
program, set by the user. After reaching the limiting value, the
meter will configure itself according to individual user's needs.
CLG-03CLG-03
www.fif.com.pl
F&F products are covered by an 24 months warranty from date of purchase
WORKING TIME METERS
- control panel, enabling programming and the monitoring of
device operation
- T input for DC signal and AC signal 50 Hz
- counting time upwards without threshold value
- 'downward' counting mode to the selected value with zero value
F&F Filipowski sp. j
ul. Konstantynowska 79/81
tel/fax 48 42 2270971
e-mail: [email protected]
95-200 Pabianice POLAND
5 908312 591832
Deescription of display and control panel
For operating and programming the meter CLG-03 is used mounted on
the front control panel . It consists of a double, eight-digit alphanumeric
display, and placed underneath the five key keyboard
Two rows
alphanumeric
eight-digit display
Control
buttons
CLG-03
000004.6
>>
RESET OK
MENU
pq
- counting working time with high state (constant voltage) at the T
input
- counting working time between two pulses given at the T
input
-counting time upwards to the selected threshold value
- external RESET input
- relay output signaling the preset meter state (contact1C/O 8A )
- relay action selection: pulse with set time length; ON→ OFF or
OFF→ ON state change
- local and total meter state memory after supply failure
- limiting access to program menu using PIN code- setting
display illumination mode
- program menu in three languages: Polish, English or Russian
Work of meter is indicayed by pulsating symbol >> located in the
top row. Measurement of time is symbolized by appearing in the
right corner of the upper line of the symbol clock. On the left side
there is a symbol representing the state of output relay
RESET
p
q
UP and DÓWN - to move between each menu items, and to
increase or decrease the value of the parameter being
edited.
OK - entrance to the selected menu item, and enter
changes.
RESET - to reset the current cycle of meter. The
programming mode allows you to go back to the higher-level
menus. If the RESET button is pressed while editing a
parameter, the program comes from the editing mode
without saving changes.
OK
FUNCTIONING
Measurement of the duration of the high
In this mode, the user specifies a set value of time the meter
counts all the time in which the input is given gates high state. The
emergence of the low mileage makes the freeze, and it will restart
when the input again appears high state. Achieving the set value
is indicated by a change in the relay outputs (NO contact
closure), and stop counting the time. At the same time the display
shows STOP and highlighting the display flashes three times.
Start a new cycle is possible only after the timer expires, the level
of the control panel (by pressing the RESET button), or via an
external reset input. To protect the system against accidental
erasure of the meter, a zero signal is activated only after three
seconds after you press the RESET button or the input signal is
given for reseting. This does not include the loop mode, where
the reset is only possible through an external signal to a reset,
and the pulse duration can not be less than ten seconds.
MENU
Signalization
of measurement of time
000012.4
>>
State of relay output
(open joint)
Current
reports of meter
Signalization
of meter work
After reaching the set value until the display shows STOP
message, and highlighting the display flashes three times. This
situation is shown in the figure below.
00006.0
STOP Ending value
of meter
Signaling to achieve
a set value
State
of relay output
(close joint)
After the entry into programming mode the meter, through the
display and clear the configuration menu, you can easily set all
the parameters of the meter.
Button functions
MENU - to move the programming mode of the system. If the
meter is in edit mode of numeric parameter, press the button
to jump to the next edition of the numb
The bottom line of the display is an indication of the current meter.
The unit is meter hours. Digit after the decimal point, depending
on the format, might indicate tenths of hours (6min Format: 0.1 =
6min., For example, 12.4 = 12godz.24min.) Or counted the
number of consecutive 10min. hours (10 minutes Format: 0.1 =
10min., for example, 12.4 = 12godz.40min., but when counting
takes place in the 0.1 ÷ 0.6 on the value of 0.6 is about 1 meter
jump unit (hour).

MENU
Format
MENU
MENU
Mode
MENU
Program
MENU
MENU
MENU
MENU
RESET
MENU
p
q
OK
000004.6
>>
To move between menu items are UP and DOWN buttons. To
enter the selected menu item, press the OK button. Exit to menu
provides a superior level of the RESET button.
Menu -> Mode
Mode menu lets you select the basic mode of operation, ie
whether the meter will measure the duration of the high state at
the entrance gate or measured is the time between two
consecutive pulses. Scheme of Menu ->.
Measurement of time between two pulses
In this mode, the counter measures the time between two
successive pulses given at the entrance gate. The advent of
pulsed positive (transition from low to high) starts counting time.
Re-emergence of such an impulse to stop counting and the
freezing of the meter. Another positive trigger starts counting
continued. When the meter reaches the preset by the user of a
change in the state of relay outputs (NO, contact closure), and
stop counting the time. At the same time the display shows STOP
and highlighting the display flashes three times.
Start a new cycle is possible only after the timer expires, the level
of the control panel (by pressing the RESET button), or via an
external reset input. To protect the system against accidental
erasure of the counter, a zero signal is activated only after three
seconds after you press the RESET button or from the input
signal is given zero.
Set value
METER PULSESRESETJOINT
ON
START STOP START STOP
SET VALUE
METER PULSESRESETJOINT
ON
START STOP START STOP
ATTENTION!
Meter retains its current state after turning off the power supply
voltage. This means that after re-power the system restore all the
settings are both meter and meter indication and relay output
status.
Programming of meter
Meter configuration is performed using a control panel with a
keyboard and display. Entry to the programming mode the meter
is done by pressing the MENU button.
This doesn’t include the loop mode, where the reset is only
possible through an external signal to a zero, and the pulse
duration can not be less than ten seconds
Course of conduct in the definition mode is as follows:
1) By the button MENU pass to main menu of meter.
2) By buttons UP or DOWN select item Menu -> Mode and press
OK.
3) Then shows Menu -> Mode included two position Mode ->
Lvele and Mode - > Slope. Level means that the meter will
measure the duration of the high state at the entrance
bramkującym.
Slope will be counted the time between successive pulses on the
input given gate. UP and DOWN buttons to select the appropriate
option and click OK. Approval of the selected option is indicated
by displaying the message saved with the name of the selected
parameter
4) From edition mode can move out by button RESET. It cause
return to main menu, without save all put changes..
OK
RESET
RESET
OK
OK
p
q
Mode
MENU
Level
Saved
Level
Mode
Slope
Saved
Slope
Mode
Password
Threshold
Signal
Language
Light

4) By buttons UP or DOWN set correct value digit of edited
position.To pass to edit digit on the next position press button
MENU.
5)In this way, you need to set all digits of set value and enter the
new value.
6) Saving changes is indicated by a message SAVED, after that
program back to Menu -> Threshold.
7) To exit the menu without saving the changes, at any time by
editing press the RESET button.
ATTENTION!
Setting a new threshold resets the current timer. There is no
impact on the timer in the program loop.
Menu -> Format
Format menu allows you to specify the time format displayed by
the meter.The unit is meter hours. The lowest value indicated on
the display is 0.1.Cyfra decimal, depending on the format, might
indicate tenths of hours (6min Format: 0.1 = 6min., For example,
12.4 = 12godz.24min.) Or counted the number of consecutive
10min. hours (10 minutes Format: 0.1 = 10min., for example, 12.4
= 12godz.40min., the counting takes place in the 0.1 ÷ 0.6 on the
value of 0.6 is about 1 meter jump unit (hour).
OK
RESET
RESET
MENU
Format
Format
6 min.
Format
10 min.
Saved
6 min.
Saved
10 min.
OK
OK
p
q
Course of conduct when determining the rounding off is as
follows:
1) By button MENU pass to main menu.
2) By buttons UP or DOWN select item Menu -> Program and
press button OK.
3) Then shows Menu -> Program included follow items:
Program -> Loop mode in which the counting time from zero
up without regard to the setpoint. Meter measures the time until
the meter overflows.
Program -> To UP meter will be time to count up from zero to a
specified (parameter Menu -> Threshold).
Program -> To DOWN zliczanie realizowane będzie w dół,
zaczynając od ustalonej wartości progowej (parameter Menu -
> Threshold), and ending with zero. By buttons UP and DOWN
select correct option and press button OK.. Enter of the
selected option is indicated by displaying the message: Saved
with the name of the selected parameter.
Proceedings in determining the time display format is as follows:
1) By button MENU pass to main menu.
2) By buttons UP and DOWN select item Menu -> Format and
press OK.
3) Then shows Menu -> Format included follow items:
Format -> 6min.
Format -> 10min.
By buttons UP and DOWN select correct option and press
button OK. Enter choosen option is indicated by disply
message. Saved by the name of the selected parameter.
4) To exit the menu without saving the changes, at any time by
editing press the RESET button
Menu -> Signal
Menu specifies the type of signal is connected to the input signal
and gate reset. There are two options here, the signal stable (DC)
and alternating signal (AC).
Menu -> Threshold
The threshold parameter determines the threshold which will be
counted at the time of the selected program to the top, or from
which starts the timer at the bottom on the chosen program. The
threshold parameter has no effect on the work counter, where the
program was chosen loop. Threshold can be set to the nearest
full hour
Proceedings in determining the threshold value is as follows:
1) By button MENU pass to main menu.
2) By buttons UP or DOWN select item Menu -> Threshold and
press button OK..
3) The bottom line will show the current setpoint. Edited currently
digit is signaled by the pulsating cursor.
Menu -> Program
The menu allows you to specify whether the meter will be tracked
from time zero to a preset threshold, counting from the threshold
to zero, or tracked without any restrictions from zero upward until
it reaches the counter overflow.
4) From edit mode you can move out by pressing the RESET
button. This withdrawal of the parent menu without saving
changes.
p
q
OK
Program
MENU
OK
Saved Program
OK
Program Saved
OK
Saved Program
RESET
Loop Loop
To Up To Up
To Down
To Down
RESET
000012
Saved
MENU
pq
+1 -1 "
MENU OK
000000
OK
RESET
000012
Threshold
Threshold
Threshold
OK
RESET
RESET
Saved
MENU
AC_50Hz
Saved
AC_50Hz
OK
OK
p
q
MENU MENU
Stable_DC
Stable_DC
SIGNAL
SIGNAL
SIGNAL

3) You will see the Menu -> Light containing the following items:
Light -> At constant - The display will be constantly illuminated.
Signaling reaches the setpoint will meter that the display will flash
three times, then returns to the highlight state. Light -> button -
The display will be highlighted only when you press any button
and 60 seconds after him. In case of the meter setpoint
highlighting blinks three times then turns off. UP and DOWN
buttons to select the correct option and click OK. Remember the
new parameter value is indicated by displaying the message,
Saved with the new value of the parameter, then the program
returns to the Menu -> Light.
4) To exit the parameter editing without saving changes, press the
RESET button.
To define the type of input signal is needed:
1) Pass to menu by pressing a buttin MENU.
2) By buttons UP or DOWN select Menu -> Signal and press
OK.
3)The will show Menu -> Signal included follow items:
Signal -> Stable_DC To input of meter will be give
permanent voltage. System will react in this case to set signal
slope, or achieve a high state.
Signal -> AC_50Hz To input of metrer will be give analog
voltage with frequency 50 Hz. In this case the system will react
to the fact that the emergence of an alternating voltage at the
terminals of control.
By buttons UP or DOWN select correct option and press button
OK. Remember the new parameter value is indicated by
displaying the message. Saved with new parameter value,
after that program back to Menu -> Signal.
4) To exit the parameter editing without saving changes, press
the RESET button.
Menu -> Language
This parameter allows to specify what language you'll see the
messages. To select messages are in Polish, English and
Russian. Menu chart is shown in the figure below.
OK
RESET
RESET
MENU Saved
Saved
OK
OK
p
qButton Button
To change a language of message you need:
1) By button MENU pass to main menu.
2) By buttons UP or DOWN select item Menu > Language and
enter by OK.
3) From list by buttons UP or DOWN select correct item and
enter by OK. Confirmation of the change of language will
appear in the new selected language.
4) To exit the option to choose the language without any
changes, press the RESET button.
Menu->Light
This parameter allowsto specify a way of highlight a meter
display.You can set the highlight permanently highlight , or
highlighting only for 60 seconds after you press any button.
To determine how the highlight you need:
1) Pass to menu by pressing a button MENU.
2) By buttons UP or DOWN select Menu -> Light and press OK.
System -> Password
Password parameter can be used to restrict access by
unauthorized users to meter menu. The password is the number
of accepting values from 0 to 999, but set the password to 0
removes the security of meter. Setting the password other than
zero introduces a meter in the secure mode. To set a password
you need:
1. By button MENU pass to main menu.
2. By buttons UP or DOWN pass to Menu > System and enter by
OK.
3. By buttons UP or DOWN select command System >
Passwordand press a button OK.
4. Meter is now in the mode of implementation of the new PIN,
which is signaled by a message New PIN. Password is entered in
the form of overt and baseline is the previous value of the
password.
5. By buttons UP or DOWN set the appropriate value of sequential
numbers, and use the MENU button, you can go to the next
edition of the numbers. After entering all the required numbers to
confirm a new PIN by pressing the OK button.
6.To exit the editing mode without saving your password, press
the RESET button.
After setting the password to access the menu meter is protected
against unauthorized access. This state is signaled by a key
symbol on the display positioned in the right top of the display.
00000999
>> Lock MENU
From this moment to enter the configuration menu of meter when
you press MENU first enter the correct PIN.
The PIN is introduced here as classified. That means you edit the
figure is visible, while the remaining two digits are hidden under
asterisk. If you enter an incorrect PIN number is displayed bad
PIN, then the meter will return to display the current value of the
meter.
PIN
>> 0
PIN
>> **6
OK
+1 -1
pq
MENU "
00000999
>>
MENU
Mode
MENU
OK
RESET
p
q
MENU
Polski
English English
Polski
Zapisane
Saved
OK
Language
Language
Language
Language
Permanently
Light
Light
Light
Permanently
System New PIN
>> 000
New PIN
>> 356
Saved
>> 356
OK
OK
RESET RESET
+1 -1
pq
MENU "
Password

ASSEMBLY
TECHNICAL DATA
Supply 24÷264v AC/DC
INPUT voltage 10÷264v AC/DC
RESET voltage 24÷264v AC/DC
Current load of joint 1P 8A
Power consumption 1,5W
Connections screw terminals 2,5mm
Working temperature -20÷50°C
Dimensions 3 modules (52,5mm)
Fixing on the rail TH-35
A100219
The system allows you to enter the PIN number, any number of
times, preventing the device blocked by too many errors at the
administration password
After entering the password the user has full access to the menu.
While no user activity for fifteen seconds (identified by the lack of
pressing any button) again causes the shift of the meter in safe
condition. The display mode of meter state when the system is not
yet secured is signaled by flashing key symbol. When the meter
goes to a safe condition, the key is displayed in a continuous
way.The device is not implemented any special passwords to
unlock. In the case of locked due to forgotten passwords, you can
delete a security giving the signal to unlock input 5 and 6 at the
time of attaching the supply voltage.
ATTENTION!
1) Turn the power distribution box in which the device is
attached.
2) Mount the device on the rail.
3) Connect power cable to joints 1 or 2.
4) Connect the other cables, according to the scheme. Please
note that when working with DC signals it is important to
maintain proper polarity.
5) Turh On the power of switchbox and of the meter.
8
4
-
3
RESET
+
-
/~
AC/DC
12
11
12
7
ˇ U
10
+/~
WIRING DIAGRAM
ATTENTION!
No unauthorised modifications are to be made in the relay
otherwise the device may be damaged or malfunction which in
turn may lead to damage of the protected engine and jeopardise
its operators. Should this warning be ignored, the producer
cannot be held responsible for any related events and is entitled
to deem this warranty invalid in the case of any complaint.
External signal does not permanently remove the security of
meter. After re-attached the power PIN is enabled
OK
+1 -1
pq
MENU "
MENU
PIN
>> 0
PIN
>> **3
00000999
>>
Incorrect
PIN
WARRANTY
1.The duration of the warranty is 24 months from the date of
purchase.
2.The warranty is valid with the receipt only.
3.Complaints must be filed at the point of purchase or directly with
the producer (tel. no. 42-2270971, e-mail: [email protected]).
4.Within the warranty period, the producer undertakes to repair or
replace the relay within 14 days from the date the unit is delivered
to the service point.
5.The purchaser has the right to have the relay replaced or to
receive a refund if an indelible defect is revealed.
6.This warranty does not cover the following:
-mechanical or chemical defects,
-defects which stem from improper use contrary to the user's
manual,
-defects which appear after the unit has been sold due to
accidents or other events for which neither the producer nor the
point of sale can be held responsible, e.g. transport damage, etc.
7.This warranty does not cover any operations which, according
to the manual, should be done by the user, e.g. mounting of the
relay, installation of the electrical system, installation of other
required electrical protection devices, recommended inspections
and tests, etc.

X-ON Electronics
Largest Supplier of Electrical and Electronic Components
Click to view similar products for Frequency Counters category:
Click to view products by F&F manufacturer:
Other Similar products are found below :
MFG-2120MA 3.060.200.383 HK47.C.10-80VDC 3.130.251.071.056 3.220.401.085 3.223.401.351 3.240.201.075 3.241.201.075
3.242.201.075 3.245.201.351 TFG-3610E TG5012A AX-DG105 AX-DG2010AF 3.100.200.383 HMF2525 3.130.251.075.056
3.130.251.351.056 BZ1224 BZ220A 3.220.401.351 3.240.201.351 3.241.201.351 3.242.201.351 3.245.201.075 3.474.901.075
3.474.901.084 3.474.911.373 DDS-3X25 0.170.000.075 0.135.200.373 TFG-3620E 0.170.000.351 TGF4162 TGF4242 GFG-3015 + RS232
HK30.G.48.230VAC/50HZ HK30.G.48.24VAC/50HZ 0.135.200.302 1803D 53220A/903 1856D GFG-8215A GFG-8250A BG4017-1248
BW4018-23050 BW4018-2450 BW7089-23050 190.004 190.003
Other manuals for CLG-03
1
Other F&F Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Katronic Technologies
Katronic Technologies KATflow 150 operating instructions

Compressed Air Alliance
Compressed Air Alliance FLT user manual

SICK
SICK MARSIC200 technical information

EIC
EIC CT007-M user manual

Brooks
Brooks GT1600 Installation and operation manual

TASKING
TASKING iSYSTEM Aurora MPC5 Series user manual