A. Application: The general purpose two-wire ultrasonic trans-
mitter provides non-contact level measurement up to 26.2’or 8m, and
is ideally suited for challenging corrosive, coating or waste liquids.
The transmitter is broadly selected for atmospheric bulk storage, day
tank, process vessel and waste sump applications. Media examples
include polymer, ink and hydrochloric acid.
B. Part Number: The part and serial numbers are located on the
wrench flat. Check the part number on the product label and confirm
which of the below model configurations you have purchased:
Part Number Range EnclosureMount
LU05-5001 1.2m (4.0’) Cable Connection 1” NPT
LU05-5061 1.2m (4.0’) Cable Connection 1” G
LU05-5101 1.2m (4.0’) Conduit Connection 1” NPT
LU05-5161 1.2m (4.0’) Conduit Connection 1” G
LU12-5001 3m (9.8’) Cable Connection 1” NPT
LU12-5061 3m (9.8’) Cable Connection 1” G
LU12-5101 3m (9.8’) Conduit Connection 1” NPT
LU12-5161 3m (9.8’) Conduit Connection 1” G
LU11-5001 5m (16.4’) Cable Connection 2” NPT
LU11-5061 5m (16.4’) Cable Connection 2” G
LU11-5101 5m (16.4’) Conduit Connection 2” NPT
LU11-5161 5m (16.4’) Conduit Connection 2” G
LU13-5001 8m (26.2’) Cable Connection 2” NPT
LU13-5061 8m (26.2’) Cable Connection 2” G
LU13-5101 8m (26.2’) Conduit Connection 2” NPT
LU13-5161 8m (26.2’) Conduit Connection 2” G
C. Conduit Enclosure: The conduit enclosure (-51_1) has a flip
cover with two 1/2” NPT female conduit ports and an internal terminal
strip for wiring. To open the enclosure, you will need a small insertion tool
such as a small screwdriver or paperclip. Insert the tool into the hole locat-
ed at the front of the enclosure and gently push on the latching mechanism
to release the cover. Rotate the hinged cover up for 135° access to the ter-
minal strip. Before closing the enclosure, make sure that the enclosure
gasket is properly seated, and that any conduit fittings, cable connec-
tors and/or plugs are installed correctly and sealed.
LU__-51_1 Enclosure Shown
About this Manual: PLEASE READ THE ENTIRE MANU-
AL PRIOR TO INSTALLING OR USING THIS PRODUCT. This
manual includes information on the LU05-5__1, LU11-5__1,
LU12-5__1 and LU13-5__1 Ultrasonic Level Transmitter from
FLOWLINE. Please refer to the part number located on the trans-
mitter label to verify the exact model configuration which you have
purchased.
User’s Responsibility for Safety: FLOWLINE manufac-
tures a broad range of level sensing technologies. While each of
these sensors is designed to operate in a wide variety of applica-
tions, it is the user’s responsibility to select a sensor model that is
appropriate for the application, install it properly, perform tests of
the installed system, and maintain all components. The failure to do
so could result in property damage or serious injury.
Proper Installation and Handling: Only properly trained
staff should install and/or repair this product. Install the transmitter
with the Viton gasket and never overtighten the transmitter within
the fitting. Always check for leaks prior to system start-up.
Wiring and Electrical: A supply voltage of 12-28 VDC is
used to power the transmitter. The sensor circuit should never
exceed a maximum of 28 volts DC. Electrical wiring of the sensor
should be performed in accordance with all applicable national,
state, and local codes.
Material Compatibility: The LU__-5__1 enclosure is made
of a flame retardant Polycarbonate (PC/ABS FR). The transducer is
made of Polyvinylidene Fluoride (PVDF). Make sure that the
model which you have selected is chemically compatible with the
application media.
Enclosure: While the transmitter housing is liquid-resistant the
LU__-5 __1 is not designed to be operational when immersed. It
should be mounted in such a way that the enclosure and transduc-
er do not come into contact with the application media under nor-
mal operational conditions.
Make a Fail-Safe System: Design a fail-safe system that
accommodates the possibility of transmitter and/or power failure.
FLOWLINE recommends the use of redundant backup systems
and alarms in addition to the primary system.
Flammable, Explosive or Hazardous Applications:
The LU__-5__1 should not be used within classified hazardous
environments.
Warning
Always use the Viton gasket when installing the LU1_-5_ _1
transmitter, and always connect the shield wire to the com-
mon ground.