The laser trigger / RPM sensor (in short: sensor) is used as
trigger for vibration measurements and for RPM measure-
ments using a PRUFTECHNIK measurement data collector.
SAFETY INFORMATION
• Read these instructions carefully prior to use.
• Use original accessories only.
• Do not use defective sensors.
• Do not open the housing.
• Prior to the installation of measuring components,
switch off the machine and secure it against restarting
according to the applicable regulations.
• Comply with the applicable safety regulations when per-
forming measurements on machines.
• Check that the measuring setup can move freely prior to
restarting the machine. Avoid contact of the measuring
setup with rotating machine parts. Risk of injury and
property damage!
• For storage and transportation, short-circuit the magnet-
ic pole at the stand using the washer supplied. This is to
minimize the magnetic field strength. Observe the safe-
ty data sheet (MSDS) for the magnet holder VIB 3.420
(www.pruftechnik.com).
• The sensor is in compliance with the relevant European
Directives. The complete Declaration of Conformity is
available at www.pruftechnik.com/certificates.
INSTALLATION
• Switch the machine off and secure it against uninten-
tional restarting.
Mount sensor to stand:
• Guide the sensor mount through
the clamping device, until the
knurled nut is centered above the
mount.
• Hand-tighten the knurled nut.
Mount stand to machine:
• Select a suitable position on the machine according to
the following criteria: Cleanliness, magnetic properties,
permissible measuring distances, minimum diameter for
curved surface: 40 mm.
• Carefully place the magnetic base with one edge first to
avoid high impact loads.
• Attach the measuring mark to the machine shaft.
• Using the cable, connect the sensor to the measuring
device.
Typical setup
Sensor
Shaft
Permissible angle range:
Reflective foil: ± 45° (green)
Contrast mark: ± 15° (yellow)
L
L: Measuring distance*
with reflective foil = 5 cm ... 100 cm
with contrast mark = 5 cm ... 20 cm
ADJUSTMENT
• Align the sensor with the laser to the measuring mark.
• Switch on the laser as follows for adjustment purposes:
- In “Balancing” operating mode, switch on the laser via
the dialog menu on the measuring screen.
- In “Multimode” operating mode, start a RPM measure-
ment, or activate the “Coast-down Analysis” measuring
task. The laser switches on automatically.
CAUTION!
Do not look into the laser beam! Risk of eye injury!
• Unlock the ball joint at the stand.
• Rotate and tilt the fixture, until the
laser beam hits the measuring mark. To
achieve stable signals, align the sensor
with a slight angle to shaft surface and
shaft axis.
• Lock the ball joint.
Measuring distances and angle range
A: Sensor VIB 6.631 / VIB 6.631 EX
B: Measuring mark (reflective foil VIB 3.306, contrast mark)
C: Stand VIB 6.632
D: Connection cable VIB 5.432-2.9
E: VIBXPERT II, VIBXPERT EX, VIBSCANNER, VIBSCANNER EX
Operation and area of application
VIB 6.631 VIB 6.631 EX
Measuring device VIBXPERT II,
VIBSCANNER
VIBXPERT EX,
VIBSCANNER EX
Area of application
B
LASER LIGHT
CLASS II LASER PRODUCT
P<1 mW, λ=670 nm
Complies with 21CFR1040.10 & 1040.11
DON'T STARE INTO BEAM
A
C
D
E
S2 S4 S6 S8
S1 S3 S5 S7 S9
VIBBUS - MUX 3494
NEXT
MUX
STRING
LINE
M
ENT
RAM
TURBALIGN
R
VIBROSPECT FFT
R
TEST
OFF
1
2345678
9
10
11
CHANNEL
TEST SHORT OPEN
VIBRATIONSENSOR
CONNECTIONBOX
VIB8.530
OUTPUT SELECTOR
-2
1 mV / ms
VIBROSPECT FFT
VIBROTIP
1
2
3
4
5
6
7
8
9
10
11
F
E
S
C
M
E
N
U
H
E
L
P
*Dependent on ambient light conditions and angle of reflection.