Fluke 73 and 77
Basic autoranging
multimeters with
TouchHold®to freeze
the measurement
display. Includes
holster and test leads.
Included accessories
Every Fluke 170 Series meter
comes packaged with TL75 test
leads, 9 V battery (installed), and
manual. The Fluke 1
79 comes with
an 80BK Temperature Probe.
Ordering information
Fluke-1
75Digital Multimeter
Fluke-1
77Digital Multimeter
Fluke-1
79Digital Multimeter
Fluke-73-3 Digital Multimeter
Fluke-77-3 Digital Multimeter
Fluke-1
79/61Combo Kit
Fluke-1
79/1ACElectricians
Combo Kit
Fluke-1
79/EDACombo Kit
Fluke-1
79/TPKCombo Kit
Fluke 73, 77, 175, 177 and
179 Digital Multimeters
Versatile meters for maintenance,
field service and bench repair.
Specifications – 170 Series
Features – 70 and 170 Series DMMs
Recommended accessories – 70 and 1
70 Series DMMs
The 170 Series have the features needed to find most
electrical, electronic, electro-mechanical and heating
and ventilation problems. They are simple to use and
have significant improvements over Fluke’s original
70 Series like true-rms, more measurement functions,
conformance to the latest safety standards, and a much
larger display that’s easier to view.
170 Series features include:
•Wide 1000 V measurement range
•True-rms for precise measurement of non linear
signals
•Capacitance, resistance, continuity and frequency
•Built-in thermometer (179 )
•Large, easy-to-read display
•Backlight for work in dim areas (177, 179)
•Min/Max to record signal fluctuations
•Free your hands with the optional TPAK magnetic
hanger
Electrical safety
All inputs are protected to measurement Category III
1000 V and Category IV 600 V. They can withstand
transient impulses in excess of 8000 V assuring your
protection from surges and spikes.
Feature 73 77 175 177 179 179/TPK
Max voltage 600 1000 1000 1000 1000 1000
True-rms
Temperature
Basic dc accuracy 0.3 % 0.3 % 0.15 % 0.09 % 0.09 % 0.09 %
Backlight
Min/Max/Avg
ToolPak meter hanging kit with magnet Opt Opt Opt Included
1All ac voltage and ac current ranges are specified from 5 % of range to 100 % of range.
210 A continuous, 20 A for up to 30 seconds.
3Voltage frequency is specified from 2 Hz to 100 kHz. Current Frequency is specified from 2 Hz to 30 kHz.
Battery life: 200 hours typical for alkaline. Size (HxWxL): 4.3 cm x 9.0 cm x 18.5 cm (1.7 in x 3.5 in x 7.3 in)
Limited lifetime warranty
Function Range and resolution Best accuracy
VDC 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V ± 0.09 % (Models 177 and 179)
± 0.15 % (Model 175)
VAC1600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V ± 1.0 % of reading
ADC 60.00 mA, 400.0 mA, 6.000 A, 10.00 A2±1.0 % of reading
AAC260.00 mA, 400.0 mA, 6.000 A, 10.00 A2± 1.5 % of reading
Resistance 600.0 Ω, 6.000 kΩ, 60.00 kΩ, 600.0 kΩ, 6.000 MΩ, 50.00 MΩ± 0.9 % of reading
Capacitance 1000 nF, 10.00 µF, 100.0 µF, 9999 µF ± 1.2 % of reading
Frequency399.99 Hz, 999.9 Hz, 9.999 Hz, 99.99 kHz ±0.1 % of reading
Temperature
(Model 1
79) -40 ºC to +400 ºC (-40 ºF to +752 ºF) 1.0 % of reading
For Combo
Kits, see page 5:
•Electrician’s 179 Multimeter
and Voltage Tester Combo Kit
•Electronics 179 Multimeter and
Deluxe Accessory Combo Kit
•179 and IR Thermometer Combo Kit
TL71 TL220 C25 80T-IR 80I-400
See page 39 See page 39 See page 44 See page 42 See page 40
Why you need a
true-rms meter
•Electronic loads with switching
power supplies or inverters distort
the ac voltage and current sine
wave
•Non true-rms meters can measure
up to 40 % low
•True-rms meters make the most
accurate measurements when the
sine wave is distorted
Non
True-rms True-rms
Waveform meter meter
Normal
sine
wave Correct Correct
Square Reads
wave 10 % high Correct
Reads
Inverter input current 40 % low Correct
Three
phase Reads
rectified 5-30 % low Correct
RMS AVG
Fluke 73
For more information, go to www.MyFlukeStore.com
12
E
l
e
c
t
r
i
c
a
l
S
a
f
e
t
y
1000 V CAT III
600 V CAT IV