manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Fluke
  6. •
  7. Thermometer
  8. •
  9. Fluke 561R User manual

Fluke 561R User manual

Other Fluke Thermometer manuals

Fluke 1551A Ex User manual

Fluke

Fluke 1551A Ex User manual

Fluke 561s User manual

Fluke

Fluke 561s User manual

Fluke 568 EX Installation instructions

Fluke

Fluke 568 EX Installation instructions

Fluke 54 Series II User manual

Fluke

Fluke 54 Series II User manual

Fluke 51 User manual

Fluke

Fluke 51 User manual

Fluke 1502A User manual

Fluke

Fluke 1502A User manual

Fluke Hart Scientific 5623A User manual

Fluke

Fluke Hart Scientific 5623A User manual

Fluke VT06 Original instructions

Fluke

Fluke VT06 Original instructions

Fluke 65 User manual

Fluke

Fluke 65 User manual

Fluke 2190A User manual

Fluke

Fluke 2190A User manual

Fluke 62 MAX User manual

Fluke

Fluke 62 MAX User manual

Fluke 568 EX User manual

Fluke

Fluke 568 EX User manual

Fluke VT06 User manual

Fluke

Fluke VT06 User manual

Fluke 1551A Ex User manual

Fluke

Fluke 1551A Ex User manual

Fluke 56X User manual

Fluke

Fluke 56X User manual

Fluke 63 User manual

Fluke

Fluke 63 User manual

Fluke 50S User manual

Fluke

Fluke 50S User manual

Fluke 62 MAX User manual

Fluke

Fluke 62 MAX User manual

Fluke 1529 User manual

Fluke

Fluke 1529 User manual

Fluke Hart Scientific 1523 Quick start guide

Fluke

Fluke Hart Scientific 1523 Quick start guide

Fluke 1551A Ex Use and care manual

Fluke

Fluke 1551A Ex Use and care manual

Fluke 1504 User manual

Fluke

Fluke 1504 User manual

Fluke 5616 User manual

Fluke

Fluke 5616 User manual

Fluke 5627A User manual

Fluke

Fluke 5627A User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Taylor 5286498 instruction manual

Taylor

Taylor 5286498 instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

561R Infrared Thermometer
Quick Reference Guide
PN 2797301 December 2006
©2006 Fluke Corporation. All rights reserved. Printed in USA.
Features
The Thermometer includes:
• Single-spot Laser Sighting
• Backlit Display
• Current Temperature Plus MIN, MAX, DIF Temperature
Displays
• Easy Emissivity Selector
• Type-K Thermocouple
• Two AA Batteries
•Users Manual on CD
Operating the Thermometer
To measure temperature, pull and hold trigger. Release
the trigger to hold a temperature reading. The
thermometer turns off when no activity is detected for
seven seconds.
Symbol Explanation
Risk of danger. Important information. See Manual.
Warning. Laser.
Conforms to requirements of European Union and
European Free Trade Association (EFTA)
Do not dispose of this product as unsorted municipal
waste. Contact Fluke or a qualified recycler for
disposal.
Battery
Chinese manufacturing mark for products
manufactured in the Peoples Republic of China (PRC)
Safety Information

Warning
A Warning identifies conditions and actions that pose hazards
to the user. To avoid electrical shock or personal injury, follow
these guidelines:
•Do not point laser directly at eye or indirectly off
reflective surfaces.
•Before using the Thermometer inspect the case. Do not use
the Thermometer if it appears damaged. Look for cracks or
missing plastic.
•Replace the batteries as soon as the battery indicator ( )
appears.
•Do not use the Thermometer if it operates abnormally.
Protection may be impaired. When in doubt, have the
Thermometer serviced.
•Do not operate the Thermometer around explosive gas,
vapor, or dust.
•Do not connect the optional external probe to live electrical
circuits.
•To avoid a burn hazard, remember that highly reflective
objects will often result in lower than actual temperature
measurements.
•Do not use in a manner not specified by this guide or users
manual or the protection supplied by the equipment may be
impaired.
Caution
To avoid damaging the thermometer or the equipment under
test protect them from the following:
• EMF (electro-magnetic fields) from arc welders, induction
heaters, etc.
• Static electricity.
• Thermal shock (caused by large or abrupt ambient
temperature changes- allow 30 minutes for the
Thermometer to stabilize before use).
• Do not leave the Thermometer on or near objects of high
temperature.
Symbols
Button Description
Battery Replacemant
Thermometer Buttons
Press
MAX, and DIF options.
and then press to toggle between the MIN,
The button is used to show the MIN, MAX, and DIF
functions in the secondary display, whichever was pressed
most recently.
Selects the emissivity setting. You can toggle between LO
(0.3), MED (0.7), or HI (0.95) using
.
You may need
to adjust emissivity for shiny metalic objects.
AA
Batteries
(2)
(+)
Laser
Trigger
Battery
Cover
Battery door
locking latch
Function Buttons
Display
Laser “On” symbol
SCAN or HOLD
ºC/ºF symbol (Celsius/Fahrenheit)
Primary temperature display
Secondary temperature display
Emissivity LO, MED, HI
Temperature values for the MIN, MAX, DIF, KTC.
KTC indicates the thermocouple temperature.
Low Battery symbol. Appears when the battery charge
is < 25%
Thermometer Display
Connecting the Temperature Probe
With probe inserted, the 561 stays on for 10 minutes (with laser
off) after trigger is released.
3
4
5
6
2
1
1
2
3
4
5
6
7
8
8
7
Locating a Hot and Cold Spot
Distance and Spot Size
Field of View
Switching between °C and °F
Switch
D:S=12:1
38 mm @
300 mm
75 mm @
900 mm
132 mm @
1500 mm
1.5 " @
12 "
3 " @
36 "
5.3 " @
60 "
S
D
Yes No
Specifications
Infrared
Measurement Range............... -40 °C to 550 °C (-40 °F to 1022 °F)
Spectral Range........................ 8 to 14 microns
Accuracy................................. ±1 % or ±1 °C (2 °F); < 0 °C (32 °F),
±1 °C (2 °F) ±0.1°/1°
(Assumes ambient operating temperature of
23 to 25 °C (73 to 77 °F))
Repeatability ........................... ±0.5 % of reading or ±1°C (2 °F)
Display Resolution .................. 0.1 °C (0.1 °F)
Secondary Display Information Maximum, Minimum, Differential, KTC
Response Time (95 %) ........... 500 ms
Distance to Spot (D:S) ............ 12:1
Emissivity Adjustment............. Three settings: low (0.3), medium (0.7),
high (0.95)
Contact Probe Input
Input Temperature Range........ -40 °C to 550 °C (-40 °F to 1022 °F)
Input Accuracy........................ Input accuracy +/- 1.1 °C (+/- 2 °F)
Display Resolution .................. 1 °C (1 °F)
Laser
Sighting .................................. Single point laser
Power ..................................... Class 2 (II) operation; Output <1 mW,
wavelength 630 to 670 nm
Bead Thermocouple Probe
Type ........................................ Type K with miniconnector
Measurment Range................. -40 °C to 260 °C (-40 °F to 500 °F)
Accuracy................................. ±1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to
500 °F). Typically within 1.1 °C
(2.0 °F) from -40 °C to 0 °C
(-40 °F to 32 °F)
Cable Length........................... 1 m (40 in) terminated with Type K
thermocouple beads
Electrical
Power Supply.......................... 2 AA Batteries (alkaline or NiCD)
Power Consumption ............... At least 12 hours battery life
Physical
Weight .................................... 0.322 kg (0.7099 lb)
Size ......................................... 17.69 cm (6.965 in) x 16.36 cm (6.441 in) x
5.18 cm (2.039 in)
Environmental
Operating Temperature Range 0 °C to 50 °C (32 °F to 120 °F)
Relative Humidity.................... 0 to 90 %, noncondensing up to 30 °C (86 °F)
Storage Temperature............... - 20 °C to 65 °C (-4 °F to 150 °F)
Optional Accessories............... Soft Case