End Cap
Setup
Warning
Isolate the machines to be aligned from mains supply.
Slide the cover plates to remove the plates from the product before mounting.
DO NOT snap the units on as this can cause painful nips and pinches.
Mount the reector unit onto the machine to be moved, and the laser unit onto the
stationary machine
Warranty
Each Fluke product is warranted to be free from defects in material and workmanship under normal
use and service. The warranty period is two years and begins on the date of shipment. Parts,
product repairs, and services are warranted for 90 days. This warranty extends only to the original
buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable
batteries, or to any product which, in Fluke’s opinion, has been misused, altered, neglected,
contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke
warrants that software will operate substantially in accordance with its functional specications for
90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that
software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user
customers only but have no authority to extend a greater or dierent warranty on behalf of Fluke.
Warranty support is available only if product is purchased through a Fluke authorized sales outlet
or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for
importation costs of repair/replacement parts when product purchased in one country is submitted
for repair in another country.
Fluke’s warranty obligation is limited, at Fluke’s option, to refund of the purchase price, free of
charge repair, or replacement of a defective product which is returned to a Fluke authorized service
center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return
authorization information, then send the product to that service center, with a description of the
diculty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage
in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid
(FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination,
alteration, accident, or abnormal condition of operation or handling, including overvoltage failures
caused by use outside the product’s specied rating, or normal wear and tear of mechanical
components, Fluke will provide an estimate of repair costs and obtain authorization before
commencing the work. Following repair, the product will be returned to the Buyer transportation
prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping
Point).
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF
ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY
CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or
exclusion or limitation of incidental or consequential damages, the limitations and exclusions
of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or
unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not
aect the validity or enforceability of any other provision.
Technical data
Laser unit 5275417
Type Semiconductor laser diode
Beam power < 1.0 mW (measured at 100 mm distance from a 7 mm diameter
aperture according to IEC 60825-1:2014 condition 3)
Beam divergence < 1.0 mrad
Beam spread 70 deg.
Maximum beam
power
< 2.8 mW (measured directly at the aperture)
Wavelength 505 – 535 nm (green visible)
Safety class Class 2 according to IEC 60825-1:2014
The laser complies with 21 CFR 1040.10 and 1040.11 except for
deviations pursuant to Laser Notice No. 50, dated June 24, 2007.
Safety
precautions
Do not look into the laser beam
Measuring
accuracy
0.2°
Measuring
distance
10 m between units
Power supply 4 LR 03 AAA alkaline batteries
Supply voltage and current with batteries at full capacity
(6 V, 150 mA)
Supply voltage and current with almost depleted batteries
(2.7 V, 380 mA)
Operating time 6 hours
Controls ON/OFF rocker switch
Environmental
protection
IP20
Relative humidity: 10% to 95% (non-condensing)
Altitude: up to 2,000 m (6560 ft)
Usage: Both indoors and outdoors
Temperature
range
Operating: -5°C to 40°C (23°F to 104°F)
Storage: -10°C to 70°C (14°F to 158°F)
Mounting method Strong magnets
Weight Approx. 0.3 kg (0.66 lb.) with batteries
Dimensions Approx. 37 x 40 x 170 mm (1 7/16” x 1 9/16” x 6 11/16”)
Housing material Gray anodized aluminium
Reector 5275421
Accuracy 0.2°
Reector surface
size
21 x 32 mm (13/16” x 1 1/4”)
Mounting method Strong magnets
Weight Approx. 0.27 kg (0.6 lb)
Dimensions Approx. 37 x 40 x 170 mm (1 7/16” x 1 9/16” x 6 11/16”)
Housing material Gray anodized aluminium
Maintenance
•The product is maintenance-free.
•Do not use the product if defective. Send the product for repair.
•The product must be repaired only by authorized service centres.
Service centres verify the safe state of the laser unit after repair
Declaration of conformity
The device fullls the EC Guidelines for electric devices and those relating to
electromagnetic compatibility as indicated in its conformity certicate.
Handling Precautions
Caution
Do not drop the product. Do not subject the product to physical shock.
Storage
Use the provided pouch to transport the units.
If the laser unit is not used for an extended period, remove the batteries, and store
them in a cool, dry and well-ventilated location.
Observe the storage temperature specied in the technical data.
To remove batteries, use your thumb or a coin and lift o the end cap
attached to the battery holder. Pull out the battery holder and remove the batteries.
ON/OFF rocker switch.
Push to turn laser beam on or o.
Reector Unit
Laser Unit