FOR-A MV-4300PS Series User manual

MV-4300PS
Redundant Power Supply for MV-4300 Series
1st Edition
INSTALLATION
GUIDE

2
Upon Receipt
MV-4300PS units and their accessories are fully inspected and adjusted prior to shipment. Check your
received items against the packing lists below. Check to ensure no damage has occurred during
shipment. If damage has occurred, or items are missing, inform your supplier immediately.
MV-4300PS Box
ITEM
QTY
REMARKS
MV-4300PS
1
For MV-4300/4310/4320
AC Cord
1 set
(Includes an AC cord retaining clip)
Installation Guide
1
(This manual)
Installing the AC Cord Retention Clip
Secure the AC cord with the supplied ladder strap/retention clip assembly to prevent accidental
removal from the unit.
Installing the clip
1) Wrap the retention clip around the AC cord (with the anchor of the ladder strap toward the
unit).
2) Insert the anchor into the hole next to the AC IN socket.
3) Lightly fasten the clip around the AC cord.
4) Plug in the power cord.
5) Slide the clip on the ladder strap toward the plug.
6) Fasten the clip tightly.
7) Gently pull on the AC cord to ensure it is secured.
Unpluging the AC cord
1) Push the tab on the retention clip up to unfasten the clip.
2) Push the tab on the ladder strap up and slide the clip back.
3) Unplug the AC cord.
2)
4)
3)
5)
6)
1)
2)

3
1. MV-4300PS (Option) Installation
IMPORTANT
To avoid electric shock, make sure that the grounding terminal is grounded before operation and/or
pull out the AC cable from the outlet.
A redundant power supply unit can be installed while the power is on, although the main unit’s power
should normally be turned off when doing so.
MV-4300 Series supports hot swappable power supplies.
How to install a new MV-4300PS into the MV-4300 Series is explained below.
(1) Completely release the screw on the right side of the front panel and open the front panel toward
the left.
POWER 1
POWER 2
FAN
ALARM
GENLOCK
PAGE
1
2
3
4
GROUP A GROUP B
GROUP C GROUP D
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
POWER 1
POWER 2
ON
OFF
ON
OFF
MV-4300
MULTI VIEWER
MENU
/RETURN
SHIFT
/PgUp
CTRL
/PgDn
MUTE
/
LOCK
/ENTER
TEST
/
(2) Remove the screws on both sides of the blank panel as shown and remove the blank panel.
POWER 1
POWER 2
POWER 1
POWER 2
(3) Insert the power supply unit (MV-4300PS) all the way to the end.
(4) Fasten the screws on both sides of the power supply (MV-4300PS).
(5) Close the front panel and refasten the screw removed from Step (1) on the right side.
(6) Plug in the AC cord into the back adapter and install the AC cord clamp.
1
AC100-240V 50/60Hz IN
2
AC100-240V 50/60Hz IN
IF
C
B
A
ALARM OUTAUDIO OUT LANLTC IN
HDMI OUTPUT3G-SDI/HD-SDI OUTPUT3G-SDI/HD-SDI/SD-SDI/COMPOSITE INPUT
87654321 4321 4321 L/R
(7) Turn the POWER2 power switch on. Verify that the POWER2 status lamp lights.
POWER 1
POWER 2
FAN
ALARM
GENLOCK
PAGE
1
2
3
4
GROUP A GROUP B
GROUP C GROUP D
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
POWER 1
POWER 2
ON
OFF
ON
OFF
MV-4300
MULTI VIEWER
MENU
/RETURN
SHIFT
/PgUp
CTRL
/PgDn
MUTE
/
LOCK
/ENTER
TEST
/
MV-4300PS installation is now complete.
Screw
Install MV-4300PS
Screws
Power switch
Status lamp

4
2. Replacing a Power Supply Unit
How to replace standard Power Supply Unit 1 of an MV-4300 Series unit to a new one is explained
below.
When a Power Supply Unit 2 (MV-4300PS) is installed, perform replacement while the main unit’s power
is on.
(1) Turn off the POWER1 power supply switch.
(2) Completely release the screw on the right side of the front panel and open the front panel toward
the left.
(3) Remove the screws on both sides of Power Supply 1 and pull out the power supply unit slowly.
POWER 1
POWER 2
POWER 1
POWER 2
(4) Insert the new power supply unit (MV-4300PS) all the way to the end.
(5) Fasten the screws on both sides of the new power supply (MV-4300PS).
(6) Close the front panel and refasten the screw removed from Step (2) on the right side.
(7) Turn the POWER1 power switch on.
(8) Verify that the POWER1 status lamp on the front panel lights.
MV-4300PS replacement is now complete.
Power Supply Unit 1
Screws

Warning
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of FCC Rules. These limits are
designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference, in
which case the user will be required to correct the interference at his own
expense.

FOR-A COMPANY LIMITED
Head Office 3-8-1 Ebisu, Shibuya-ku, Tokyo 150-0013, Japan
Overseas Division Tel: +81(0)3-3446-3936 Fax: +81(0)3-3445-5116
Japan Branch Offices Osaka/Okinawa/Fukuoka/Hiroshima/Nagoya/Sendai/Sapporo
R&D/Production Sakura Center/Sapporo Center
FOR-A Co
r
poration of America Corporate Office/Service Cente
r
11155 Knott Ave., Suite G, H & I, Cypress, CA 90630, U.S.A.
Tel: +1 714-894-3311 Fax: +1 714-894-5399
FOR-A Corporation of America Northeast Office
1360 Clifton Ave., Clifton, NJ 07012, U.S.A.
Tel: +1 973-220-8471 Fax: +1 714-894-5399
FOR-A Corporation of America Southeast Office
Tel: +1-305-773-7608
FOR-A Corporation of America Support Cente
r
2400 N.E. Waldo Road, Gainesville, FL 32609, U.S.A.
Tel: +1 352-371-1505 Fax: +1 714-894-5399
FOR-A Latin America and the Caribbean Miami Office
Tel: +1 657-600-5759
FOR-A Latin America and the Caribbean Sao Paulo Office
Tel: +55 (0)11-99913-3751
FOR-A Europe S.r.l.
Via Volturno, 37, 20861 Brugherio MB, Italy
Tel: +39 039-916-4811 Fax: +39 039-878-140
FOR A UK Limited
Trident Court, 1 Oakcroft Road Chessington, KT9 1BD, U.K.
Tel: +44 (0)20-3044-2935 Fax: +44 (0)20-3044-2936
FOR-A Italia S.r.l.
Via Volturno, 37, 20861 Brugherio MB, Italy
Tel: +39 039-881-086/103 Fax: +39 039-878-140
FOR-A Corporation of Korea
1007, 57-5, Yangsan-ro, Yeongdeungpo-gu, Seoul 07271, Korea
Tel: +82 (0)2-2637-0761 Fax: +82 (0)2-2637-0760
FOR-A China Limited
1618 Huateng Building, No. 302, 3 District, Jinsong, Chaoyang, Beijing 100021, China
Tel: +86 (0)10-8721-6023 Fax: +86 (0)10-8721-6033
FOR-A Middle East Africa Office
Aurora Tower, Office 1407, Dubai Media City, P.O. Box 502688, Dubai, UAE
Tel: +971 (0)4 551 5830 Fax: +971 (0)4 551 5832
FOR-A India Private Limited. Mumbai Office
2nd Floor, Valecha Chambers, Link Road, Andheri (W), Mumbai 400053, India
Tel : +91-(0)22-2673-3623 Fax︓+91-(0)22-2639-3415
FOR-A India Private Limited. Delhi Office
8th floor, World Trade Tower, Sector-16, Noida, Uttar Pradesh 201301, India
Tel: +91-(0)12-0423-8674
FOR-A South East Asia Office
Studio 09, Rm. A1, 3/F., Phase 1, Hang Fung Ind. Bldg., 2G Hok Yuen St., Hung Hom, Hong Kong
Tel : +852 2110-1352
A
ugust 13, 2020 Printed in Japan
http://www.for-a.com/
This manual suits for next models
2
Table of contents
Other FOR-A Power Supply manuals
Popular Power Supply manuals by other brands

COUGAR
COUGAR STC750 manual

Bpt
Bpt VAS/101 installation instructions

Elektro-Automatik
Elektro-Automatik PSB 9000 3U Series operating guide

Cross Technologies
Cross Technologies 2000-2 LNB Series instruction manual

Raychem
Raychem C-150-E manual

American Magnetics
American Magnetics 430 Installation, operation and maintenance instructions