Rio-S Installation manual doc. R24
Exit
Loop
Foto 2
Edge 1
Foto 1
2.1 Safety examples
Scheme shows two safety photo
beams protecting both sides of
a gate. A loop detector inside
is wired to open the gate.
One safety edge is on
the tip of one gate.
Forematic
9 Vanalloys Estate
Stoke Row
Henley RG9 5QW www.forematic.com QPR24v2-RIOS
Edge 1 to
re-open
Replace
edge with a link
if edge is not required
24v 0v NO C NO
Loop detector
Supply B is only on while the gate is in
motion. Loop detectors andintercoms
needs to be on all the time. Take power
from the +24V input terminal.
3.1 Programming remotes
Top remote button is for full opening. Lower button is to open M1 leaf only
Adding Switch on SW1/4. Press Code button for 2 sec. Coding LED
DL6 will come on. Press Code again. DL6 flashes. Press the
new remote top button twice for full opening, or bottom
button twice for single leaf opening. Switch off SW1/4.
Deleting Switch on SW1/4. Press and hold the Code for 10 secs. All
remotes in memory are now deleted. Switch off SW1/4.
Electric gate locks may draw high
peak currents. Check minimum cable
requirements. We would suggest at
least 0.75mm. Lamps are usually less
than 1A each, A dc sounder inside
the control box is a lamp alternative
to provide a gate in motion warning
for users.
2.2 Buttons
Connect buttons to D inputs. Use these
inputs for access controls as well, like
keypads or an intercom. The wireless
button FR11 and the wireless keypad
FA62 are simple to fit.
2.3 Lock & Lamps
WARRANTY
3 year return to base warranty covers defective manufacture and material. The warranty does not cover
accidental damage, misuse,or abnormal wear. Warrantyis conditional ongood installation, maintenance and
service recommended in this manual. Warranty is void if subject of unauthorised modification or repair, or
abnormal input voltage. This does not affect your statutory rights
Declaration of Conformity
We hereby declare, that gateopeners F-600 hasbeen manufactured in accordance
with the following standards ornormative documents
EN 60335-2-95: 2004 EN 60335-1/A13: 2008/A2:2006 EN 62233: 2008
EN 61000-3-2: 2006, +A1: 2009 +A2: 2009 EN 61000-3-3: 2008
EN 55014-1: 2006+A1: 2009 EN 55014-2: 1997 +A2: 2008 EN 50371: 2002
In accordance with the provisions of the following directives
98/37/EC MachineryDirective with amending directives
2006/95/EC LV Directive
2004/108/EEC EMCDirective
1999/5/EC R&TTE Directive
23.03.2011 –FOREMATIC
9 Vanalloys Estate, Stoke Row, Mr H WYNN JONES
HenleyRG9 5QW, United Kingdom Director
3.3 Safety warnings
Automatic gates can be hazardous. The operatoris responsible to provide adequate
hazard warning. Onlyusers given hazard awarenesstrainingshould be allowed to
operate the gate. The gate must be installed and maintained byqualified pers ons .
Users must checkthe gate’s safetyfunctions regularlyand report anydefects.
Operators must ensure the risk zone is clear of childrenor the general public during
operation. Do not allow children to operate or play near the gate.
3.2 Settings
RIO-S has a self setting routine. You
will need a coded in remote. Open
gates fully, set the 4 adjustments to
half way, switch ON SW2/8. Press the
‘ST’button or remote to start the test.
Wait until the gates are fully closed.
Press the ‘ST’button again, Gates will
open. Switch OFF SW2/8.
Adjustments
‘LV’ is the slow down speed. Correctly
set, LV is adjusted to decelerate the
gate neatly up to the limits or physical
stops without banging or wobbling.
‘RV’ is the mid run speed. Set RV for a
smooth acceleration and slow down
to the LV point. Be sure to test the
immediate stop when a photobeam is
interrupted. Heavy gates may damage
the motor on immediate stop.
FORCE sets the trip force for the gate
to stop and reverse direction. Set it
to the lowest needed to run reliably
and consistently. Clockwise is weak.
TIMER is set to cut motor power a
few secs after the normal run time,
before pressure sensitive reversal.
LEDs indicating in / out states.
DL1 Lock output
DL2 F1 input, on is normal
DL3 F2 input, on is normal
DL4 D2 input, off is normal
DL5 D1 input, off is normal