- 1 -
Rio-S Installation manual doc. R24
doc. R24
iss V1.2
RIO-S installation manual
Double leaf
24V control
panel
Specifications
Supply 230Vac 50/60Hz @ 5A
Motors 2x 24Vdc
Aux supply 24Vdc @ 1A
Housing ABS IP44, 1.8kg
Dimensions 227 x 277 x 108mm
Receiver 433MHz rolling code
•25rolling coderemotecapacity
•Auto-close0sto3 mins
•Single ordouble leaf
•Softstop, optional softstart
•Interleaf delay 0 –3s
•4 forcesettings
•Pressuresensitive reversal
•Autoruntimesetting
1.0 Description
Rio-S is a 24V panel for a light weight double leaf
swing gates. There are 2 PCBs and a transformer.
Space is reserved for backup batteries.
1.1 Inputs & outputs
The plug in control connector has 2 safety inputs
and 2 control inputs. Control inputs are normally
open active low, safety input are normally closed.
Open inputs are 5v. All return to common term C
The lock output ‘K’& lamp output ‘L’are relay
contacts switching to +24Vdc. Photobeam supply
‘B’switches on when the motor is in motion to
conserve power when running on batteries.
Output B can be set to 12V or 24V depending on
the position of jumper link J1.
The DC lamp output includes a flasher circuit
1.2 Terminal functions
D1) Full gate opening. Function selected on SW2
6OFF - 4 step auto, open–stop-close-stop
6ON -2 step auto, open-close function
D2) Pedestrian opning opens one leaf.
F1) Re-opens the gate during closure. The gate re-
closes when the obstacle is removedand following
the normal delay or. No action during opening.
Delays close if active while open.
F2) If activated during opening, the gate stops dead.
Stays still until next command. No response while
closing.
M-N) Motor output. G is protective earth.
B) Photobeamsupply. On when gate is moving.
L) 24Vdc lamp or buzzeroutput. No flashing is
required because the switching is in controller.
K) 24Vdc lock output. Pulses the lock for
1 sec before the gate begins to open.
Con2) 12Vdc relay output to switch a 230Vac lamp.
Power board power plug DIP switches
Motor connectors control connector
M1
M2
LOCK DCL - + - IR1 IR2 -DR1 DR2
1.3 DIP switches
SW2 8way
DIP1 Interleaf delay 1 sec
DIP2 Interleaf delay 2 secs
both on for delay 3 secs
DIP3 --- not used ---
DIP4 OFF , M1 opens first, ON M2 opens first
DIP5 OFF for double leaf, ON for single leaf
DIP6 OFF for 4 step auto, ON for 2 step auto.
DIP7 When ON, the gate must close fully before
a new open signal can be accepted.
DIP8 --- not used ---
SW1 auto-close
delays add together
DIP1 + 30 secs
DIP2 + 60 secs
DIP3 + 120 secs
DIP4 code enable
- 2 -
Rio-S Installation manual doc. R24
Exit
Loop
Foto 2
Edge 1
Foto 1
2.1 Safety examples
Scheme shows two safety photo
beams protecting both sides of
a gate. A loop detector inside
is wired to open the gate.
One safety edge is on
the tip of one gate.
Forematic
9 Vanalloys Estate
Stoke Row
Henley RG9 5QW www.forematic.com QPR24v2-RIOS
Edge 1 to
re-open
Replace
edge with a link
if edge is not required
Rx
0v
24V
C
N/C
Tx
24V
0V
Foto 2
Rx
0v
24V
C
N/C
Tx
24V
0V
Foto 1

24v 0v NO C NO
Loop detector
Supply B is only on while the gate is in
motion. Loop detectors andintercoms
needs to be on all the time. Take power
from the +24V input terminal.
3.1 Programming remotes
Top remote button is for full opening. Lower button is to open M1 leaf only
Adding Switch on SW1/4. Press Code button for 2 sec. Coding LED
DL6 will come on. Press Code again. DL6 flashes. Press the
new remote top button twice for full opening, or bottom
button twice for single leaf opening. Switch off SW1/4.
Deleting Switch on SW1/4. Press and hold the Code for 10 secs. All
remotes in memory are now deleted. Switch off SW1/4.
Ped
button
Open
button
Electric gate locks may draw high
peak currents. Check minimum cable
requirements. We would suggest at
least 0.75mm. Lamps are usually less
than 1A each, A dc sounder inside
the control box is a lamp alternative
to provide a gate in motion warning
for users.
LOCK dc LAMP.
2.2 Buttons
Connect buttons to D inputs. Use these
inputs for access controls as well, like
keypads or an intercom. The wireless
button FR11 and the wireless keypad
FA62 are simple to fit.
2.3 Lock & Lamps
WARRANTY
3 year return to base warranty covers defective manufacture and material. The warranty does not cover
accidental damage, misuse,or abnormal wear. Warrantyis conditional ongood installation, maintenance and
service recommended in this manual. Warranty is void if subject of unauthorised modification or repair, or
abnormal input voltage. This does not affect your statutory rights
Declaration of Conformity
We hereby declare, that gateopeners F-600 hasbeen manufactured in accordance
with the following standards ornormative documents
EN 60335-2-95: 2004 EN 60335-1/A13: 2008/A2:2006 EN 62233: 2008
EN 61000-3-2: 2006, +A1: 2009 +A2: 2009 EN 61000-3-3: 2008
EN 55014-1: 2006+A1: 2009 EN 55014-2: 1997 +A2: 2008 EN 50371: 2002
In accordance with the provisions of the following directives
98/37/EC MachineryDirective with amending directives
2006/95/EC LV Directive
2004/108/EEC EMCDirective
1999/5/EC R&TTE Directive
23.03.2011 –FOREMATIC
9 Vanalloys Estate, Stoke Row, Mr H WYNN JONES
HenleyRG9 5QW, United Kingdom Director
3.3 Safety warnings
Automatic gates can be hazardous. The operatoris responsible to provide adequate
hazard warning. Onlyusers given hazard awarenesstrainingshould be allowed to
operate the gate. The gate must be installed and maintained byqualified pers ons .
Users must checkthe gate’s safetyfunctions regularlyand report anydefects.
Operators must ensure the risk zone is clear of childrenor the general public during
operation. Do not allow children to operate or play near the gate.
3.2 Settings
RIO-S has a self setting routine. You
will need a coded in remote. Open
gates fully, set the 4 adjustments to
half way, switch ON SW2/8. Press the
‘ST’button or remote to start the test.
Wait until the gates are fully closed.
Press the ‘ST’button again, Gates will
open. Switch OFF SW2/8.
Adjustments
‘LV’ is the slow down speed. Correctly
set, LV is adjusted to decelerate the
gate neatly up to the limits or physical
stops without banging or wobbling.
‘RV’ is the mid run speed. Set RV for a
smooth acceleration and slow down
to the LV point. Be sure to test the
immediate stop when a photobeam is
interrupted. Heavy gates may damage
the motor on immediate stop.
FORCE sets the trip force for the gate
to stop and reverse direction. Set it
to the lowest needed to run reliably
and consistently. Clockwise is weak.
TIMER is set to cut motor power a
few secs after the normal run time,
before pressure sensitive reversal.
LEDs indicating in / out states.
DL1 Lock output
DL2 F1 input, on is normal
DL3 F2 input, on is normal
DL4 D2 input, off is normal
DL5 D1 input, off is normal

Other Forematic Gate Opener manuals

Forematic F550 User manual

Forematic

Forematic F550 User manual

Forematic RIO-D User manual

Forematic

Forematic RIO-D User manual

Forematic RIO-R User manual

Forematic

Forematic RIO-R User manual

Forematic AXEL F730 User manual

Forematic

Forematic AXEL F730 User manual

Forematic PICO PK-550 User manual

Forematic

Forematic PICO PK-550 User manual

Forematic RIO-R User manual

Forematic

Forematic RIO-R User manual

Forematic RETRO User manual

Forematic

Forematic RETRO User manual

Popular Gate Opener manuals by other brands

CAME BY-3500T installation manual

CAME

CAME BY-3500T installation manual

V2 BINGO400 user manual

V2

V2 BINGO400 user manual

Nice ROBUS350 Instructions and warnings for the fitter

Nice

Nice ROBUS350 Instructions and warnings for the fitter

SOMFY Elixo 500 3S io installation instructions

SOMFY

SOMFY Elixo 500 3S io installation instructions

DITEC 0DT869 Installation manual, maintenance, use

DITEC

DITEC 0DT869 Installation manual, maintenance, use

Chamberlain LiftMaster SL930 user manual

Chamberlain

Chamberlain LiftMaster SL930 user manual

Rotech Sentinel MB24 installation instructions

Rotech

Rotech Sentinel MB24 installation instructions

Nice MhouseKit WG2W Instructions and warnings for installation and use

Nice

Nice MhouseKit WG2W Instructions and warnings for installation and use

CAME FROG series installation manual

CAME

CAME FROG series installation manual

Leb Electronics LB7 manual

Leb Electronics

Leb Electronics LB7 manual

Cardin SLX Series instruction manual

Cardin

Cardin SLX Series instruction manual

Chamberlain 050ACTWFATS Installation

Chamberlain

Chamberlain 050ACTWFATS Installation

DoorHan PCB-SH Programming instructions

DoorHan

DoorHan PCB-SH Programming instructions

GTO 2000XL installation manual

GTO

GTO 2000XL installation manual

CAME FAST Series Mounting procedure

CAME

CAME FAST Series Mounting procedure

Chamberlain MyQ Smart Garage Hub installation guide

Chamberlain

Chamberlain MyQ Smart Garage Hub installation guide

BFT SUB installation manual

BFT

BFT SUB installation manual

Chamberlain LA 400PKGU installation manual

Chamberlain

Chamberlain LA 400PKGU installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.