- 1 -
Rio-R Installation manual doc. R12
doc. R12
iss V1.2
RIO-R installation manual
Contents
Description
Technical characteristics
Safety warnings
User instructions
Barrier arm options
Dimensions & layout
Installation
Controller description
Functions inputs & outputs
Accessory description
Wiring
Double leaf
gate control
panel
Specifications
Supply 230Vac 50/60Hz @ 5A
Motors 2x 100W ACIM’s
Aux supply 24Vdc @ 1A
Housing ABS IP44, 1.8kg
Dimensions 227 x 277 x 108mm
Receiver 433MHz rolling code
60 rolling code remote capacity
Auto-close 10s to 7mins
Single or double leaf
Soft stop, optional soft start
Interleaf delay 0 –9s
4 force settings
Pressure sensitive reversal
Auto run time setting
Transformer Display Accessory header
connector
+ - P
Main Code Buttons
Fuse
230Vac supply motor wiring control wiring lock wiring
Motor 1 1-2-3 - 1 neutral, 2 open live, 3 close live
Motor 2 4-5-6 - 4 neutral, 5 open live, 6 close live
AC lamp 7-8 - 7 neutral, 8 lamp live during motion
Open button 9-10 - 9 input, 10 com (-ve)
Pedestrian 11-12 - 11 input, 12 com (-ve)
Safety 2 13-15 - 11 input, 12 com (-ve)
Safety 1 14-15 - 11 input, 12 com (-ve)
Stop button 16-17 - 16 input, 17 com (-ve)
DC lamp 18-20 - 18 (+24v), 20 switch to gnd
DC lock 19-21 - 19 (+24v), 21 switch to gnd
1.0 Description
RIO-R panel is for AC induction motors with limit switches.
For single or double leaf gates / doors. Programming is
with navigation buttons and an LCD display.
1.1 Inputs & outputs
RIO-R supports two command inputs and two safety inputs.
Inputs have +5V pull ups, switching to ground. Command
inputs are active low. Safety inputs are N/C normally low.
Solid state switching outputs are provided for an electric
lock that operates for 1sec on opening. A solid state 24Vdc
flashing light output switches at 1Hz. An accessory header
is provided for powered external trigger devices such as a
keypad, loop detector, exit device, or access control device.
1.2 Input functions
SBS input Open –stop-close-stop function. When stopped
during open the gate re-closes after auto-close delay. When
stopped during closing, gate waits for next command.
Ped input Same function as SBS input, but on one gate.
Safety 1 Re-opens the gate during closure. Assuming the
danger is removed, the gate re-closes after normal delay.
No action during opening. Delays close if active while open.
Safety 2 If activated during opening, the gate stops dead.
Stays still until next command. No response while closing.
Stop During opening, stops, then re-closes after
normal auto-close delay. Stops during closing.
Wiring assumes motors include capacitors & limit switches
DC lamp does not need a flasher
WUVWXYWLaDCPCF2F1CECAALdK
Display
In normal running, the left digit shows the
state of inputs. Black is active. You should
have three black horizontal bars.
F1 = IR1
E = Stop
F2 = IR2
D = Door
P = Ped
Right digit segments rotate anti-clockwise
During normal running. Both digits show
alpha numeric digits during programming.