DSECanada Inc INSTALLATION GUIDE
FS 105 with ALARM
TECHNICAL SUPPORT 514-255-0446 & 1-800-667-6820
5540 Boul. Metropolitain Est, St-Leonard, Qc., H1S 1A6 Tel. : 514-255-2720 Fax : 514-255-1367
FAR 040526 11/08/04 2
CERTIFIED ISO 9001 PRODUCT
C - TO GET INTO PROGRAMMING MODE
1-Disarm the system.
2-Turn Ign On then Off.
3-Within 10sec, hold the programming
button for 5 sec, 5 chirps and 5 parking
lights will confirm that you are entering
into the programming mode.
4-Push and release the programming
button (1 chirp / 1 Flash each time) the
number of times corresponding to the
chosen option. To go to another option
push again the additional time from the
last location. To verify at what option you
are in, count the number of flashes of the
LED after each pause.
5-Push the button Lock, Option, Start
or Lock + Unlock accordingly to the
selected option.
TO QUIT PROGRAMMING MODE Repeat
step 2 & 3 except that parking lights will
flash 5 times (instead of 5 chirps) to confirm
the end of the operation.
Factory Default Setting
Selection Press LOCK button (1 chirp & 1 flash) Press START button (2 chirps & 2 flashes)
Option 1 Go to Last Setting Go to Factory Setting
Option 2 GAS DIESEL (go to option 12 )
Option 3 Go to the table below to program for Aux outputs Go to the table below tto program for Aux outputs
Option 4 Horn Siren
Option 5 Lock Pulse 0.8 sec 4 sec
Option 6 Unlock 1 pulse 2 pulses
Option 7 Pulse before ignition to disarm factory alarm 1.5 sec 0.5 sec
Option 8 Running time 20 minutes 12 minutes
Option 9 When remote start Door Re-Lock Disable Enable
Option 10 Minimum cranking 0.7 sec See below for programming
Option 11 Maximum cranking 10 sec See below for programming
Option 12 Timer-Diesel ( go to option 13 )Glow-plug- Diesel *Black/Green Fig.2
Option 13 Timer – Diesel 8 sec “Wait to Start” 18 sec “Wait to Start”
Option 14 Ignition / Foot brake lock Enable Disable
Option 15 Starter Kill Passive (after 60 sec) Active
Option 16 Trunk release output Channel Expander (see section F )
Option 17 Valet / Override via Programming Switch 6 times Foot Brake pedal
Option 18 Without Alarm With Alarm
Option 19 Dome by pass 60sec when remote start Disable Enable
Option 20 Dome diagnostic Enable Disable
Table Selection for Options #3, #10, #11
Press Lock Press Start Press Lock+Unlock Press Option
Second Auxiliary Option #3 Second IGN Second ACC Second START Starter Kill
Min Cranking time Option #10 0.7 second 0.9 second 1.2 seconds N/A
Max Cranking time Option #11 10 seconds 3.5 seconds 20 seconds N/A