Introduction
www.frsky-rc.com www.frsky-rc.com
FrSky 2.4GHz ACCST X8R Manual
Range Check
A pre-
flight range check should be done before each flying session. Reflections from nearby metal fences,
concrete buildings or tress can cause loss of signal both during range check and during the flight. Follow the
steps below to perform the range check.
1. Place the model at least 60cm (two feet) above non-metal contaminated ground (e.g. on a wooden bench).
2. The receiver antennas should be separated in the model, and do not touch the ground.
3. The module antenna should be in a vertical position.
4. Turn on the transmitter and the receiver, press the F/S button on the XJT module for 4 seconds to enter
range check mode, the RED LED will be off, GREEN LED will flash rapidly. The effective distance will be
decreased to 1/30 (at least 30m).
5. Walk away from the model while simultaneously operating the controls on the transmitter to confirm all
controls’ normal operation.
6. Press the F/S button on the XJT module for 1~2 seconds to exit range check mode, RED LED will be back
on, indicating normal operation is back.
Failsafe
Failsafe is a useful feature in which all controls move to a preset position whenever the control signal is lost for
a period of time. X8R supports failsafe function for all channels. Follow the steps below to set failsafe positions
for each channel:
1. Bind the receiver first and turn on both the transmitter and the receiver;
2. Move the controls to the desired failsafe position for all channels;
3. Press briefly the F/S button on the receiver (less than 1 second). The Green LED will flash twice, indicating
the failsafe position has been set in the receiver.
To disable the failsafe function, re-bind the receiver.
Failsafe is recommended to set when system is firstly used, or receiver has been re-bound. Follow steps below
to set failsafe.
Option-1.How to set failsafe to a user-determined state on lost signal:
1) Bind the receiver to the transmitter module first and turn on both the transmitter and the receiver;
2) Move the controls to desired failsafe position for all channels;
3) Press briefly the F/S button on the receiver and you are done.
Option-2. How to set failsafe for no pulses on lost signal:
1) Turn off the transmitter, power on the receiver, and then press briefly the F/S button on the receiver.
Note: If failsafe is not set, failsafe default will hold last position before signal is lost. In this case, there
exists risk that your model will fly away or cause injury.
Specifications
Binding Procedure
Binding is the process of uniquely associating a particular receiver to a transmitter module. A transmitter module
can be bound to multiple receivers (not to be used simultaneously). A receiver can only be bound to one
transmitter module.
Follow the steps below to finish the binding procedure.
1. Turn on the transmitter while holding the F/S button on the module (please refer to the module instruction
manual for switch positions). Release the button. The RED LED on the XJT module will flash, indicating the
transmitter is ready to bind to the receiver.
2.
Set X8R receiver in bind mode (see below chart for details), The RED LED on the receiver will flash,
indicating the binding process is completed.
3. Turn off both the transmitter and the receiver.
4. Turn on the transmitter and connect the battery. The GREEN LED on the receiver indicates the receiver is
receiving commands from the transmitter. The receiver/transmitter module binding will not have to be repeated,
unless one of the two is replaced.
What’s New!
More number of channels: 1~8ch from conventional channel outputs, 1~16ch from SBUS port,
or combine two X8R to become a 16 channels receiver.
Parallel two X8R to become a 16 channel receiver.
With RSSI PWM output (0~3.3V)
Smart Port enabled, realizing two-way full duplex transmission.
Thank you for purchasing FrSky X8R 8/16ch full duplex telemetry receiver.In order to fully enjoy the benefits of
this system, please read the instruction manual carefully and set up the device as described below.
Overview
Green LED
ON
Flashing
OFF
Flash Twice
Red LED
Flashing
OFF
Flashing
OFF
Status
Binding
Normal
Signal Lost
Failsafe Set
Dimension: 46.47×26.78×14.12mm (L × W × H)
Weight: 16.6g
Number of Channels: 16CH (1~8ch from conventional channel outputs, 1~16ch from SBUS port
or combine two X8R to become a 16 channels receiver)
With RSSI PWM output (0~3.3V)
Operating Voltage Range: 4.0~10V
Operating Current: 100mA@5V
Operating Range: full range (>1.5km)
Firmware Upgradeable
Compatibility: FrSky DFT/DJT/DHT/DHT-U in D_mode
FrSky Taranis X9D Plus/XJT in D8 mode
FrSky Taranis X9D Plus/XJT in D16 mode
X8R-EU version only works with FrSky Taranis X9D Plus-EU version/XJT-EU version in D16-EU
mode.
Note: After binding procedure is completed, recycle the power and check if the receiver is really under
control by linked transmitter.
Mode of X8R Telemetry Channel Output Jumped before Bind
(signal pins) F/S Button
Mode 2(D16)
Mode 3(D16)
Mode 4(D16)
Mode 5(D16)
√
√
√
×
×
CH1~CH8 CH7&CH8
CH3&CH4
CH1&CH2
CH1&CH2, CH3&CH4
CH1~CH8
CH9~CH16
CH9~CH16
CH1~CH8 No Jumper
connect the battery to any available
channel output (no need to hold the
F/S button on X8R)
connect the battery to any available
channel output while holding the F/S
button on X8R
For more details, please check the complete manual for X8R from www.frsky-rc.com - Download -Manual.
Should you have other questions, please send e-mails to FrSky technical support [email protected].
Receiver Mode and Binding Operation:
Mode 1(D8)
Receiver Mode select & Bind Operation
When combine two X8R to become a 16CH receiver, you need to disable telemetry on either one of the
two X8R’s as above chart.
X8R-EU version only works with FrSky Taranis X9D Plus-EU version/XJT-EU version in D16-EU mode.
PORT
Smart Port (S. Port) is a signal wire full duplex digital transmission interface developed by FrSky
Electronic Co., Ltd. All products enabled with Smart Port (including XJT module, X8R receiver,
new hub-less sensors, new Smart Dashboard,etc), serial port user data and other user input/ output devices
can be connected without limitations for numbers or sequences at a high transmission speed.
Smart Port
SBUS Port
(CH1-CH16)
Conventional Channel
Outputs (CH1-CH8)
RSSI Outport
F/S Button
LED
Please be attention that the Smart Port Protocol is only running in D16 mode.

Other manuals for X8R

3

This manual suits for next models

1

Other FrSky Receiver manuals

FrSky S6R User manual

FrSky

FrSky S6R User manual

FrSky D8R-XP User manual

FrSky

FrSky D8R-XP User manual

FrSky TARANIS X9D User manual

FrSky

FrSky TARANIS X9D User manual

FrSky X8R User manual

FrSky

FrSky X8R User manual

FrSky Delta 8 User manual

FrSky

FrSky Delta 8 User manual

FrSky RX8R PRO User manual

FrSky

FrSky RX8R PRO User manual

FrSky ACCST G-RX6 User manual

FrSky

FrSky ACCST G-RX6 User manual

FrSky HORUS X10 User manual

FrSky

FrSky HORUS X10 User manual

FrSky X4R-SB User manual

FrSky

FrSky X4R-SB User manual

FrSky TWIN Series User manual

FrSky

FrSky TWIN Series User manual

FrSky X4R-SB User manual

FrSky

FrSky X4R-SB User manual

FrSky R9 User manual

FrSky

FrSky R9 User manual

FrSky ARCHER PLUS RS User manual

FrSky

FrSky ARCHER PLUS RS User manual

FrSky HORUS X10 User manual

FrSky

FrSky HORUS X10 User manual

FrSky R9 User manual

FrSky

FrSky R9 User manual

FrSky RX6R User manual

FrSky

FrSky RX6R User manual

FrSky DFT User manual

FrSky

FrSky DFT User manual

FrSky ARCHER R10 PRO User manual

FrSky

FrSky ARCHER R10 PRO User manual

FrSky ACCESS G-RX8 User manual

FrSky

FrSky ACCESS G-RX8 User manual

FrSky ARCHER R8 PRO User manual

FrSky

FrSky ARCHER R8 PRO User manual

FrSky TD R12 User manual

FrSky

FrSky TD R12 User manual

FrSky ACCESS G-RX6 User manual

FrSky

FrSky ACCESS G-RX6 User manual

FrSky TARANIS X9D User manual

FrSky

FrSky TARANIS X9D User manual

FrSky V8FR-II User manual

FrSky

FrSky V8FR-II User manual

Popular Receiver manuals by other brands

XM Satellite Radio SA10113 user guide

XM Satellite Radio

XM Satellite Radio SA10113 user guide

ashtech HDS800 Reference manual

ashtech

ashtech HDS800 Reference manual

Omnex Generic R170 Other

Omnex

Omnex Generic R170 Other

Hama 00053174 operating instructions

Hama

Hama 00053174 operating instructions

CaryMart S6C-AC220-ANT2 manual

CaryMart

CaryMart S6C-AC220-ANT2 manual

Renkforce 2235189 operating instructions

Renkforce

Renkforce 2235189 operating instructions

Strong Digital Satellite Receiver user manual

Strong

Strong Digital Satellite Receiver user manual

Williams Sound TGS 100 operating instructions

Williams Sound

Williams Sound TGS 100 operating instructions

Yamaha RX-V800 owner's manual

Yamaha

Yamaha RX-V800 owner's manual

Denon AVR 2805 - AV Receiver manual

Denon

Denon AVR 2805 - AV Receiver manual

Harman Kardon STEREO RECITAL TA224 Instructional manual

Harman Kardon

Harman Kardon STEREO RECITAL TA224 Instructional manual

Pioneer Elite VSX-43 Information sheet

Pioneer

Pioneer Elite VSX-43 Information sheet

Freeview DTVS-DSR1 user guide

Freeview

Freeview DTVS-DSR1 user guide

Stageline txs-892 instruction manual

Stageline

Stageline txs-892 instruction manual

Manhattan Plaza HDR S 500GB user guide

Manhattan

Manhattan Plaza HDR S 500GB user guide

SecurityMan SM-451DR user manual

SecurityMan

SecurityMan SM-451DR user manual

Drivedata RT800 quick start guide

Drivedata

Drivedata RT800 quick start guide

FUTABA R324SBS instruction manual

FUTABA

FUTABA R324SBS instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.