2-6
Code Name Data setting range
Increment
Unit
Change when
running
Data copying
Default setting
Data format No.
Torque vector
control
Software version
which can be
used
E20 Signal Assignment to Selecting function code data assigns the corresponding
(Transistor signal) function to terminals [Y1] to [Y2], [Y3A/C] to [Y5A/C],
[Y1] and [30A/B/C] as listed below. --NY12 1-
E21 [Y2] Setting the value of 1000s in parentheses ( ) shown below --NY78 1-
E22 (Relay contact signal) assigns a negative logic output to a terminal.
[Y3A/C] --NY21-
E23 [Y4A/C] --NY12 1-
E24 [Y5A/C] --NY57 1-
E27 [30A/B/C] --NY99 1-
0 (1000): RUN Inverter running Y
1 (1001): FAR Speed arrival Y
2 (1002): FDT Speed detected Y
3 (1003): LU Undervoltage detected Y
10 (1010): RDY Inverter ready to run Y
12 (1012): SW52-2MC control Y
25 (1025): FAN Cooling fan operation Y
26 (1026): TRY Auto-resetting Y
27 (1027): U-DO Universal Do Y
28 (1028): OH Overheat early warning Y
30 (1030): LIFE Service life alarm Y
31 (1031): FDT2 Speed detected Y
35 (1035): RUN2 Inverter output on Y
37 (1037): ID Current detected Y
38 (1038): ID2 Current detected 2 Y
52 (1052): FRUN Encoder rotating in forward direction N
53 (1053): RRUN Encoder rotating in reverse direction N
55 (1055): AX2 Run command activated Y
56 (1056): THM Motor overheat detected(PTC) Y
57 (1057): BRKS Brake control Y
70 (1070): DNZS Speed existence N
71 (1071): DSAG Speed agreement N
72 (1072): FAR3 Speed arrival 3 Y
73 (1073): DACC During acceleration Y
74 (1074): DDEC During deceleration Y
75 (1075): DZR During zero speed N
76 (1076): PG-ABN PG abnormal N
78 (1078): DOPEN Door control Y
99 (1099): ALM Alarm output Y
101 (1101): DECF EN terminal detection circuit error Y
102 (1102): ENOFF EN terminal OFF Y
104 (1104): LVD Low voltage detected Y
105 (1105): EAC Electrical angle cycle Y
107 (1107): DTUNE During pole position offset tuning N
109 (1109): RRD Recommended running direction N
110 (1110): ALM2 Drive continuance alarm output Y
111 (1111) : SD Shutdown confirmation Y
112 (1112): IPL Input power limitation Y
114 (1114): SW52-3 MC control(Run command activated) Y
115 (1115): PTD Pole tuning done N
116 (1116): DSD Detection speed direction N
121 (1121): TDCL Travel direction changes lifetime early warning Y
122 (1122): TDCP Travel direction changes pulse Y
123 (1123): SCC Short-circuit control Y
124 (1124): CEND Deliverrance operation Calculation end N 500
126 (1126): PTD-Z Pole tuning done with reference to Z-signal N
127 (1127): LC1 Loadcell LV1 detection N
128 (1128): LCF Loadcell full load detection N
129 (1129): LCO Loadcell overload detection N
141 (1141): CLO1 Customizable logic output signal 1 Y
142 (1142): CLO2 Customizable logic output signal 2 Y
143 (1143): CLO3 Customizable logic output signal 3 Y
144 (1144): CLO4 Customizable logic output signal 4 Y
145 (1145): CLO5 Customizable logic output signal 5 Y
146 (1146): CLO6 Customizable logic output signal 6 Y
147 (1147): CLO7 Customizable logic output signal 7 Y
148 (1148): CLO8 Customizable logic output signal 8 Y
149 (1149): CLO9 Customizable logic output signal 9 Y
150 (1150): CLO10 Customizable logic output signal 10 Y