- (01 - 04) -
DUCT TYPE
ARU9-18RLF
DUCT TYPE
ARU9-18RLF
SPECIFICATIONS3.
Note :
Specications are based on the following conditions.
Cooling : Indoor temperature of 80°F (26.67°C) DB / 67°F (19.44°C) WB, and outdoor temperature of 95°F (35°C) DB / 75°F (23.9°C) WB.
Heating : Indoor temperature of 70°F (21.11°C) DB / 59°F (15°C) WB, and outdoor temperature of 47°F (8.33°C) DB / 43°F (6.11°C) WB.
Standard static pressure : 0.10in.WG (25Pa)
Pipe length : 24ft.7in (7.5m), Height difference:0 m. (Outdoor unit-Indoor unit)
The protective function may work when using it outside the operation range.
*: The maximum current is the maximum value when operated within the operation range.
Type DUCTED MODEL
INVERTER HEAT PUMP
Model name ARU9RLF ARU12RLF ARU18RLF
Power source 208 / 230V ~ 60Hz
Available boltage range 187 - 253V ~ 60Hz
Capacity
Cooling
Rated kW 2.64 3.52 5.28
Btu/h 9,000 12,000 18,000
Min - Max kW 0.90 - 3.60 0.90 - 4.00 0.90 - 5.90
Btu/h 3,100 - 12,000 3,100 - 13,600 3,100 - 20,100
Heating
Rated kW 3.52 4.69 6.33
Btu/h 12,000 16,000 21,600
Min - Max kW 0.90 - 5.28 0.90 - 5.70 0.90 - 7.50
Btu/h 3,100 - 18,000 3,100 - 19,400 3,100 - 25,600
Input power
Cooling Rated
kW
0.62 0.94 1.50
Max 1.40 1.45 2.15
Heating Rated 0.85 1.30 1.67
Max 1.80 2.00 2.60
Current Cooling Rated A3.0 4.4 6.6
Heating 3.9 6.0 7.3
EER Cooling kW/kW 4.25 3.74 3.52
Btu/hW 14.5 12.8 12.0
COP Heating kW/kW 4.14 3.60 3.79
Btu/hW 14.1 12.3 12.9
SEER Cooling Btu/hW 21.5 20.0 19.7
HSPF Heating Btu/hW 12.2 11.5 11. 3
Power factor Cooling %90 94 98
Heating 94 94 99
Moisture removal pints/h (l/h) 1.5 (0.7) 2.7 (1.3) 4.2 (2.0)
Maximum operating current * Cooling A9.3 9.4 10.0
Heating 10.8 10.9 14.0
Fan
Airow rate
Cooling
High
CFM
(m3/h)
353 (600) 383 (650) 554 (940)
Med 324 (550) 353 (600) 518 (880)
Low 294 (500) 324 (550) 483 (820)
Quiet 265 (450) 283 (480) 442 (750)
Heating
High 353 (600) 383 (650) 554 (940)
Med 324 (550) 353 (600) 518 (880)
Low 294 (500) 324 (550) 483 (820)
Quiet 265 (450) 283 (480) 442 (750)
Type × Q'ty Sirocco fan × 2 Sirocco fan × 3
Motor Output W 81 96
Recommended static pressure in. WG (Pa) 0 to 0.36 (0 to 90)
Sound pressure level
Cooling
High
dB (A)
28 29 32
Med 27 28 30
Low 26 27 29
Quiet 25 26 27
Heating
High 28 29 32
Med 26 28 30
Low 25 27 29
Quiet 24 24 27
Heat exchanger
Dimension
(H × W × D) in. (mm) 11-9/16 × 19-11/16 × 1-9/16
(294×500×39.9)
11-9/16 × 27-9/16 × 1-9/16
(294×700×39.9)
Fin pitch FPI 20
Rows × Stages 3 × 14
Pipe type Copper tube
Fin type Aluminum
Enclosure Material GALVANIZED STEEL SHEET
Color -
Dimensions
(H × W × D)
Net
in. (mm)
7-25/32 × 27-9/16 × 24-13/32
(198 × 700 × 620)
7-25/32 × 35-7/16 × 24-13/32
(198 × 900 × 620)
Gross 10-7/8 × 38-1/8 × 30-13/32
(276 × 968 × 772)
10-7/8 × 46 × 30-13/32
(276 × 1168 × 772)
Weight Net lb. (kg) 41 (19) 50 (23)
Gross 58 (26) 59 (27)
Connection pipe Size Liquid in. (mm) Ø1/4 (Ø6.35)
Gas Ø3/8 (Ø9.52) Ø1/2 (Ø12.7)
Method Flare
Operation range Cooling °F (°C) 64 to 90 (18 to 32)
%RH 80 or less
Heating °F (°C) 60 to 88 (16 to 30)
Remote controller type Wired [Wireless (option)]
Drain hose
Material HARD PVC
Size in. (mm) Ø3/4 (Ø20.7) (I.D.)
Ø1-1/16 (Ø26.6) (O.D.)