Funtin AirRadio FTH-SOR2 User manual

1Smart Combustible Gas Detector
Cloud Interconnection
Funtin Home AirRadio WIFI Smart Natural Gas Detector R2 is an
automatic high-sensitivity gas leak alarm. When the natural gas (methane)
leak occurs it will automatically aissue a 70dB alarm sound, and in the first
time through the WIFI signal to send a leak warning to your phone APP(If
used with the solenoid valve, it will issue a warning at the same time to
control the solenoid valveand cut off the gas source) to protect your
family's life and property safety. When the leak warning is eliminated, it will
automatically return to the detection state.
Connect with mobile App. Interact with the third party equipment.
Calculate the risk of leakage base on the analysis of the historical data.
Intelligent Prediction
Triple Alarm
Visual & Audible alarm given from the device;
Alarm information pushed by internet;
Alert Message sent to bounded mobile phone.
Instruction of LED Status Strip
The ring indicator keep emitting with green light- Normal working status
Electromagnetic valve
Self-testbutton
RingIndicator
Network connection key
Power cord
Expire indicator
正常 报警 故障 失效
Buzzer
WIFIindicator
The ring indicator blinks with yellow light- Fault status
The ring indicator blinks with red light-Alarm Status
Network connection instruction
Working without WIFI
Applicabe in the environment without WIFI.
Plug in the deveice and it will transmit an audible and visual signals
when gas leak occurs.
Working with WIFI
Applicable in the environment with WIFI.
Plug in the device and scan the QR
code to dowmload the APP.
According to the instruction of your
mobile App and the indicator of the
detector to finish the network
connection.
According to the instruction of your mobile App and the
indicator of the detector to finish the network connection.
Remote monitoring and account management
1) Start the mobile App and check the connected device list to monitor the
detecting data of your home. Once gas leaks, the device will give off visual
and audible alarm and also send the alarm information to your mobile App.
2) The device could be bound with more than one mobile App and add
multiple phone numbers for emergency. When leakage occurs, the cloud
will send message to the bound mobile phones.
Special Conditions
1) When Installation location changed, press network connection key and
hold on for 5 seconds to active the reset function. And adapt the new
network refer to networking instruction.
2) For reselling the device, please delete the device information on mobile
App.
Button introduction
Self-test button is used to detect whether the alarm function is normal and
to reset the device. Press the self-test butoon, the ring indicator light
displays red, green and yellow. At the same time, the buzzer beeps.
Self-test function
Press the network connection key and hold on for 5s to reset the network.
Network resetting function
Websit : https://www.funtintech.com
Tel : 86 13760453400
eMail: [email protected]
Address :
B201 4F Niulanqian Build Baoan District Shenzhen, China
Zip : 518000
Welcome to follow our facebook:
https://www.facebook.com/funtintech,
any questions can leave a message to tell us,
we will reply you ASAP.
THANK YOU FOR READING :)
CONTACT
Funtin Home AirRadio WIFI Smart Natural Gas Detector
R2

Installation Instruction
Installation location
The detector and gas source should be
located in the same same room.
1~3m is the best distance from the gas
source to the detector.
The detector should be installed within
30cm from the ceiling.
Installation methods
1. Used on the wall with the material of ceramic, glass, wood , etc.
2. Keep the wall clean before installation.
3. Stick the device on the wall and press for 10s to make it stable.
Stick to the wall
1. Used on the wall with the material of cement and paint.
2. Hang on the fixed nail in the wall.
Hang on the wall
Network connection key
Screws
glue location
Precautions
Don’t install in the following location
Close the gas stove.
Where steam or oil smoke exit.
Near fan,door, and window where there is a large flow of air and
vapor.
Maintenance
1) During the usage period, activate the self-test at least once six month to
confirm that the device works normally.
2) It’s suggested to clean the shell of the combustible gas detector
frequently to prevent its air hole being blocked by dust. When cleaning the
shell of the device, use clean soft brush or dry fluffy cloth without
detergent, decolorizer and polish. Cut off power supply when cleaning the
shell.
3) R2 is designed for indoor use only. Please avoid contacting with rain or
moisture, and avoid falling, knock, disassemble the equipment, otherwise it
causes device malfuction.
4)The lifespan is 5 years under normal working environment . Please
replace with a new one if the device exceed the service life.
Sampling Method
Problems and Solutions Technology Specification
Problem Cause Analysis Solution
Green power
indicator does
not work
Model
Detecting Gas
Working Environment
Sampling Method
Testing Range
Alarm Presetting Level
Warm-up Time
Sensor Type
Life Span
Working Voltage
Weight
Dimension
Alarm Method
Alarm Sound
Press
“self-test/mute”
button but
no response
No response
to target gas
Keep alarming
after warm-up
Connectivity of
power supply
Power indicator breaks
Circuit breaks
Warm-up
does not finish
Circuit breaks
Work environment
filled with organics
like smoke,
alcohol steam,
fume, perfume
and so on
The storage period
is too long
Circuit breaks
Check the
connectivity
Call customer service
Call customer service
Wait till
warm-up finishes
Call customer service
Move the device
to clean air the test
if it work normally
Supply power to age
for over 2 hours
Call customer service
FTH-SOR2
Natural gas ( CH4, Methane)
Natural diffusion
0~100% LEL
7% LEL
180±10S
Semiconductor
5 Yeas(Under normal working environment)
AC 100V-240V
150g
85.6*85*40.5mm
≥70dB
Temperature: 0 ~ 40 degree Celsius
Humidity: <95%RH (No Frost)
Visual, audible signals and network
pushing alarm