EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GE
  6. •
  7. Air Conditioner
  8. •
  9. GE AJCH08ACB User manual

GE AJCH08ACB User manual

Other GE Air Conditioner manuals

GE AZ61H09EAB Manual

GE

GE AZ61H09EAB Manual

GE Appliances Zoneline 8500 series User manual

GE

GE Appliances Zoneline 8500 series User manual

GE AJCM10ACDW1 Operating instructions

GE

GE AJCM10ACDW1 Operating instructions

GE ASTD5 and Operating instructions

GE

GE ASTD5 and Operating instructions

GE AHR05 Operating instructions

GE

GE AHR05 Operating instructions

GE AJ806L Training manual

GE

GE AJ806L Training manual

GE ClearView AHTT06BC Original instructions

GE

GE ClearView AHTT06BC Original instructions

GE AKH08 Series Operating instructions

GE

GE AKH08 Series Operating instructions

GE AKM05LN Operating instructions

GE

GE AKM05LN Operating instructions

GE ASR05 Operating instructions

GE

GE ASR05 Operating instructions

GE Carry-Cool AT505 User manual

GE

GE Carry-Cool AT505 User manual

GE APSA13 Operating instructions

GE

GE APSA13 Operating instructions

GE AGQ05LJ User manual

GE

GE AGQ05LJ User manual

GE AEQ10 and User manual

GE

GE AEQ10 and User manual

GE AVV1O Training manual

GE

GE AVV1O Training manual

GE AKQ08AN User instructions

GE

GE AKQ08AN User instructions

GE AJES09DC User instructions

GE

GE AJES09DC User instructions

GE AS0CD09 Series Original instructions

GE

GE AS0CD09 Series Original instructions

GE AGM12AB Operating instructions

GE

GE AGM12AB Operating instructions

GE AEM08 Series Operating instructions

GE

GE AEM08 Series Operating instructions

GE AEW05 Operating instructions

GE

GE AEW05 Operating instructions

GE APWA14 Operating instructions

GE

GE APWA14 Operating instructions

GE ASM14 Operating instructions

GE

GE ASM14 Operating instructions

GE ASH06 Operating instructions

GE

GE ASH06 Operating instructions

Popular Air Conditioner manuals by other brands

Panasonic CS-E12HKEW operating instructions

Panasonic

Panasonic CS-E12HKEW operating instructions

Mitsubishi Electric MSZ-GE60VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE60VA null

Samsung AVMFC052EA0(4) null

Samsung

Samsung AVMFC052EA0(4) null

Haier HSU-09H03/R null

Haier

Haier HSU-09H03/R null

Haier HSU-24C03 null

Haier

Haier HSU-24C03 null

Mitsubishi Electric MSZ-GE22VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE22VA null

Samsung AVMCH052CA1 null

Samsung

Samsung AVMCH052CA1 null

nedis ACMB1WT7 quick start guide

nedis

nedis ACMB1WT7 quick start guide

Daikin FCFV50A Operation manual

Daikin

Daikin FCFV50A Operation manual

Fujitsu Inverter ASBA30JFC operating manual

Fujitsu

Fujitsu Inverter ASBA30JFC operating manual

Toshiba RAS-M10SMUV-E installation manual

Toshiba

Toshiba RAS-M10SMUV-E installation manual

Daikin FXLQ20MAVE Operation manual

Daikin

Daikin FXLQ20MAVE Operation manual

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

CIAT

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron AAC6000 instruction manual

Bestron

Bestron AAC6000 instruction manual

Frigidaire FFRE0533S1E0 Use & care guide

Frigidaire

Frigidaire FFRE0533S1E0 Use & care guide

Samsung AS09HM3N user manual

Samsung

Samsung AS09HM3N user manual

Frigidaire CRA073PU11 use & care

Frigidaire

Frigidaire CRA073PU11 use & care

Soleus Air GB-PAC-08E4 operating instructions

Soleus Air

Soleus Air GB-PAC-08E4 operating instructions

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Specification Revised 2/06
390232
AJCH08ACB – GE® ENERGY STAR® 115 Volt Built-In Room Air Conditioner
GE Appliances
Parallel
Perpendicular
Wall Oulets
All wiring including installation of receptacle must be made in
accordance with local electrical codes and regulations.
Electrical outlet should be in reach of line cord.
Note:
Aluminum wiring may pose special problems – consult a
qualified electrician.
115V
15 Amp
230/208V
20 Amp
Tandem
Large Tandem
230/208V
15 Amp
230/208V
30 Amp
Premium, Deluxe and Value Model
Wall Case Dimensions (in inches)
Note: When installing units in through-the-wall applications.
Do not restrict air flow areas.
26
15-5/8
16-7/8
AJT08DG QSART
Wall Case Dimensions (in inches)
Note: When installing slide-out chassis units in through-the-wall
applications, keep louvers free. Do not restrict air flow areas.
R
Total capacity and E.E.R.
ratings are calculated
based on the Association
of Home Appliance
Manufacturers’ standards.
As an ENERGY STAR®
partner, GE has determined
that this product meets the
ENERGY STAR guidelines
for energy efficiency.
R
Listed by
Underwriters
Laboratories
For answers to your Monogram,
® GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.
115V
15 Amp
Parallel
Specification Revised 2/06
390232
GE Appliances
AJCH08ACB – GE® ENERGY STAR® 115 Volt Built-In Room Air Conditioner
Dimensions (in inches)
Installation Information: A finished opening of 26-1/8" x 15-3/4" clear
of intrusions is required. Keep clearance of 4" from side walls. Brick
veneer or frame walls should have wood studding surrounding case to
provide firm anchoring with screws. Case can be fastened directly to
brick or block walls with screws sunk in lead expansion shields.
Note: Units should be caulked on all four sides of case to the building
exterior to assure building integrity.
Two Wall Cases for Tenant Option Installation
When the air conditioner is offered as a tenant option, these wall
cases provide protection against outside elements.
RAB47 – includes wall case, exterior grille and steel closure panels.
RAB48 – includes wall case, exterior grille, steel closure panel and
two layers of insulation.
Standard Wall Case RAB46
Solid-sided wall case fabricated of galvanized steel with baked enamel
finish. Welded areas are coated with a sealing compound to help resist
rust and corrosion. Polymer gasket surrounds opening to assure tight
weather seal. Aluminum grille (RAG13) is included. Panels on interior and
between case and grille provide weather protection prior to installation
of chassis.provide firm anchoring with screws. Case can be fastened
directly to brick or block walls with screws sunk in lead expansion shields.
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk 
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position

Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk 
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position

Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk 
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position

R
Total capacity and E.E.R.
ratings are calculated
based on the Association
of Home Appliance
Manufacturers’ standards.
As an ENERGY STAR®
partner, GE has determined
that this product meets the
ENERGY STAR guidelines
for energy efficiency.
R
Listed by
Underwriters
Laboratories
For answers to your Monogram,
® GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center® service, 800.626.2000.
Specification Revised 2/06
390232
GE Appliances
AJCH08ACB – GE® ENERGY STAR® 115 Volt Built-In Room Air Conditioner
Features and Benefits
• 8,000 BTU
• 9.5 EER
• 115 Volts
• ENERGY STAR® qualified
• Mechanical controls
• Variable position thermostat
• Four-way air direction
• Up-front, washable air filter
• 2 Cool/2 fan speeds
• Model AJCH08ACB – Cameo White
TEMP MODE
AJCH08ACB
AJCH10ACB
AJCH10DCB
AJCH12DCB
As an ENERGY STAR®
partner, GE has determined
that this product meets the
ENERGY STAR guidelines
for energy efficiency.