EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GE
  6. •
  7. Air Conditioner
  8. •
  9. GE AJES10DCC User manual

GE AJES10DCC User manual

Other GE Air Conditioner manuals

GE AQV06 User manual

GE

GE AQV06 User manual

GE AJEQ06LCD User manual

GE

GE AJEQ06LCD User manual

GE AHED05AC User manual

GE

GE AHED05AC User manual

GE Zoneline AZ9VH Operating instructions

GE

GE Zoneline AZ9VH Operating instructions

GE CLIMATISEUR AEE23 User manual

GE

GE CLIMATISEUR AEE23 User manual

GE Zoneline AZ91H09E E Series User manual

GE

GE Zoneline AZ91H09E E Series User manual

GE AEE18DP Assembly instructions

GE

GE AEE18DP Assembly instructions

GE AKQ12DNT1 Operating instructions

GE

GE AKQ12DNT1 Operating instructions

GE ASQ05LL Manual

GE

GE ASQ05LL Manual

GE AKM14AN User instructions

GE

GE AKM14AN User instructions

GE AVX06 Training manual

GE

GE AVX06 Training manual

GE ASW10 Original instructions

GE

GE ASW10 Original instructions

GE Appliances AHM24DPH1 Operating instructions

GE

GE Appliances AHM24DPH1 Operating instructions

GE CLIMATISEUR AEM18* Operating instructions

GE

GE CLIMATISEUR AEM18* Operating instructions

GE ASM06LL User manual

GE

GE ASM06LL User manual

GE AJEQ12DCD Assembly instructions

GE

GE AJEQ12DCD Assembly instructions

GE AKQ06 Operating instructions

GE

GE AKQ06 Operating instructions

GE GAIRZ09IG Series Operating instructions

GE

GE GAIRZ09IG Series Operating instructions

GE AHU05LY User manual

GE

GE AHU05LY User manual

GE ASM12 Operating instructions

GE

GE ASM12 Operating instructions

GE AJCS10DCB Assembly instructions

GE

GE AJCS10DCB Assembly instructions

GE AJCS08ACA User guide

GE

GE AJCS08ACA User guide

GE ASQ14AK Manual

GE

GE ASQ14AK Manual

GE AEM12AV Operating instructions

GE

GE AEM12AV Operating instructions

Popular Air Conditioner manuals by other brands

Panasonic CS-E12HKEW operating instructions

Panasonic

Panasonic CS-E12HKEW operating instructions

Mitsubishi Electric MSZ-GE60VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE60VA null

Samsung AVMFC052EA0(4) null

Samsung

Samsung AVMFC052EA0(4) null

Haier HSU-09H03/R null

Haier

Haier HSU-09H03/R null

Haier HSU-24C03 null

Haier

Haier HSU-24C03 null

Mitsubishi Electric MSZ-GE22VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE22VA null

Samsung AVMCH052CA1 null

Samsung

Samsung AVMCH052CA1 null

nedis ACMB1WT7 quick start guide

nedis

nedis ACMB1WT7 quick start guide

Daikin FCFV50A Operation manual

Daikin

Daikin FCFV50A Operation manual

Fujitsu Inverter ASBA30JFC operating manual

Fujitsu

Fujitsu Inverter ASBA30JFC operating manual

Toshiba RAS-M10SMUV-E installation manual

Toshiba

Toshiba RAS-M10SMUV-E installation manual

Daikin FXLQ20MAVE Operation manual

Daikin

Daikin FXLQ20MAVE Operation manual

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

CIAT

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron AAC6000 instruction manual

Bestron

Bestron AAC6000 instruction manual

Frigidaire FFRE0533S1E0 Use & care guide

Frigidaire

Frigidaire FFRE0533S1E0 Use & care guide

Samsung AS09HM3N user manual

Samsung

Samsung AS09HM3N user manual

Frigidaire CRA073PU11 use & care

Frigidaire

Frigidaire CRA073PU11 use & care

Soleus Air GB-PAC-08E4 operating instructions

Soleus Air

Soleus Air GB-PAC-08E4 operating instructions

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Total volume and shelf
area are calculated by
the Association of Home
Appliance Manufacturers’
standards.
AJES10DCC
GE®230/208 Volt Window/Wall Mount Heat and Cool Unit
Wall Case Dimensions and Installation Information (in inches)
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™or
GE®appliance questions, visit our website at
ge.com or call GE Answer Center®service,
800.626.2000.
Specification Created 1/07 390318
R
Parallel
Perpendicular
Wall Oulets
All wiring including installation of receptacle must be made in
accordance with local electrical codes and regulations.
Electrical outlet should be in reach of line cord.
Note:
Aluminum wiring may pose special problems – consult a
qualified electrician.
115V
15 Amp
230/208V
20 Amp
Tandem
Large Tandem
230/208V
15 Amp
230/208V
30 Amp
Premium, Deluxe and Value Model
Wall Case Dimensions (in inches)
Note: When installing units in through-the-wall applications.
Do not restrict air flow areas.
26
15-5/8
16-7/8
AJT08DG QSART
Note: When installing slide-out chassis units in through-the-wall
applications, keep louvers free. Do not restrict air flow areas.
230/208V
20 Amp
Perpendicular
Total volume and shelf
area are calculated by
the Association of Home
Appliance Manufacturers’
standards.
AJES10DCC
GE®230/208 Volt Window/Wall Mount Heat and Cool Unit
Wall Case Dimensions and Installation Information (in inches)
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™or
GE®appliance questions, visit our website at
ge.com or call GE Answer Center®service,
800.626.2000.
Specification Created 1/07 390318
R
Installation Information: A finished opening of 26-1/8" x 15-3/4"
clear of intrusions is required. Keep clearance of 4" from side
walls. Brick veneer or frame walls should have wood studding
surrounding case to provide firm anchoring with screws. Case
can be fastened directly to brick or block walls with screws sunk
in lead expansion shields.
Note: Units should be caulked on all four sides of case to the
building exterior to assure building integrity.
Two Wall Cases for Tenant Option Installation
When the air conditioner is offered as a tenant option, these
wall cases provide protection against outside elements.
RAB47 – includes wall case, exterior grille and steel
closure panels.
RAB48 – includes wall case, exterior grille, steel closure panel
and two layers of insulation.
Standard Wall Case RAB46
Solid-sided wall case fabricated of galvanized steel with
baked enamel finish. Welded areas are coated with a sealing
compound to help resist rust and corrosion. Polymer gasket
surrounds opening to assure tight weather seal. Aluminum grille
(RAG13) is included. Panels on interior and between case and
grille provide weather protection prior to installation of chassis.
Provide firm anchoring with screws. Case can be fastened
directly to brick or block walls with screws sunk in lead
expansion shields.
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
Total volume and shelf
area are calculated by
the Association of Home
Appliance Manufacturers’
standards.
AJES10DCC
GE®230/208 Volt Window/Wall Mount Heat and Cool Unit
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™or
GE®appliance questions, visit our website at
ge.com or call GE Answer Center®service,
800.626.2000.
Specification Created 1/07 390318
R
Features and Benefits
• 9,900/9,700 BTU
• 11,600/9,480 BTU heat
• 3,670/3,010 Watts heat
• 9.5/9.5 EER
• 230/208 Volts
• Mechanical controls
• Variable position thermostat
• Four-way air direction
• Up-front, washable air filter
• 2 cool/2 heat/2 fan only speeds
• Model AJES10DCC – Soft Gray