manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GE
  6. •
  7. Dryer
  8. •
  9. GE DSKS433 User manual

GE DSKS433 User manual

- Risk of Fire
• To reduce the risk of severe injury or death, follow all
installation instructions.
&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HG
installer.
• Install the clothes dryer according to these instructions
and in accordance with local codes. In the absence of
local codes, installation must comply with the NATIONAL
ELECTRICAL CODE, ANSI/NFPA NO. 70.
• This dryer must be exhausted to the outdoors.
•
Use only 4” rigid metal ducting for exhausting the clothes
dryer to the outdoors.
'2127LQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJ
PDWHULDOV,IÀH[LEOHPHWDOVHPLULJLGRUIRLOW\SHGXFWLV
installed, it must be UL listed and installed in accordance with
the instructions found in “Connecting The Dryer To House Vent”
on page 4 of this manual. Flexible venting materials are known
to collapse, be easily crushed, and trap lint. These conditions
ZLOOREVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH
• Do not install or store this appliance in any location where
it could be exposed to water and or weather.
6DYHWKHVHLQVWUXFWLRQV,QVWDOOHUV%HVXUHWROHDYHWKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU
DETERMINE ELECTRICAL REQUIREMENTS FOR YOUR DRYER MODEL
7KLVGU\HUPXVWEHFRQQHFWHGWRDQLQGLYLGXDOEUDQFKFLUFXLWRISURSHUYROWDJHDQGIUHTXHQF\DVVSHFL¿HGRQ5DWLQJ3ODWHORFDWHG
LQVLGHGU\HUGRRUZLWKQRRWKHUDSSOLDQFHVRU¿[WXUHVDWWDFKHG
%UDQFKFLUFXLWPXVWEHSURWHFWHGE\WKHUHTXLUHGWLPHGHOD\IXVHVRUFLUFXLWEUHDNHUV9RU9LQVWDOODWLRQDPSV9
LQVWDOODWLRQRUDPSV
• The electrical installation must conform to the national and local codes.
208V AND 240V MODELS ARE NOT APPROVED FOR 120V INSTALLATION.
Installation Instructions (USA only)
MODELS DSKS433 & DSKS333 MUST BE INSTALLED WITH CONTROL PANEL AT BOTTOM TO OPERATE ADEQUATELY.
UNPACKING AND PREPARING FOR INSTALLATION
Prepare the area and exhaust for installation of new dryer.
&KHFNDQGHQVXUHWKHH[LVWLQJH[WHUQDOH[KDXVWLVFOHDQDQGPHHWVDWWDFKHGLQVWDOODWLRQVSHFL¿FDWLRQV
Remove the literature and accessories bag from the dryer drum. Place the literature in a convenient place.
Using foam pads from dryer carton, turn dryer upside down as shown.
Install knobs. For location, refer to the Owner’s Manual.
Dryer is now ready to be mounted above washer using accessory kit.
Remove the foam shipping pads from under dryer.
Move the dryer to the desired location.
Follow the steps in the following pages to connect the dryer to the external exhaust and power supply.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
• IMPORTANT- Save these instructions for local
inspector’s use.
• IMPORTANT- Observe all governing codes
and ordinances.
• Note to Installer -%HVXUHWROHDYHWKHVH
instructions with the customer.
• Note to Customer - Keep these instructions with
your Owner’s Manual for future reference.
%HIRUHWKHROGGU\HULVUHPRYHGIURPVHUYLFHRU
discarded, remove the dryer door.
• Service information and the wiring diagram are
located in the control console.
• Do not allow children on or in the appliance. Close
supervision of children is necessary when the
appliance is used near children.
,QVWDOOWKHGU\HUZKHUHWKHWHPSHUDWXUHLVDERYH)
for satisfactory operation of the dryer control system.
• Product failure due to improper installation is not
covered under the Warranty.
'U\HUVLQVWDOOHGLQJDUDJHVLIDOORZHGE\ORFDOFRGHV
PXVWEHHOHYDWHGLQFKHVFPDERYHWKHÀRRU
TOOLS YOU WILL NEED
31-3000326 Rev 1 09-23
Questions? Call: 800.GE.CARES (US)or visit our web site at: www.GEAppliances.com (US)
Printed in Mexico
WARNING
Ŷ
ŶAppliance power
cord kit
QRWSURYLGHG
ZLWKDSSOLDQFH
8/UDWHG9
$ZLWKRUSURQJV
Identify the plug type
as per the house
receptacle before
purchasing line cord.
MATERIALS YOU WILL NEED
Ŷ
Ŷ4” dia.
metal
elbow
Ŷ
Ŷ4” Duct clamps
RU 4” spring
FODPSV
Ŷ
ŶSafety
glasses
Ŷ
ŶGloves
Ŷ
ŶExhaust
hood
Ŷ
Ŷ4” dia. flexible metal
VHPLULJLG8//LVWHG
WUDQVLWLRQGXFWLIQHHGHG
.LW:;;
LQFOXGHVHOERZV
Ŷ
Ŷ4” dia. metal duct
UHFRPPHQGHG
Ŷ
Ŷ´6WUDLQ
relief
8/
UHFRJQL]HG
Ŷ
ŶAluminum foil
tape
Ŷ
Ŷ4” dia. flexible metal
IRLOW\SH8//LVWHG
WUDQVLWLRQGXFWLIQHHGHG
Ŷ
ŶSlip Joint Pliers
Ŷ
Ŷ
)ODW%ODGHDQG3KLOOLSV6FUHZGULYHUV
STACKING KITS FOR DRYERS
(Comes with individual Installation Instructions)
Over washer
- Use Wall Mount Kit WMK-35 or
- Stack Rack DSDR24 or
- Stack Rack DSR-24 or
-
Stack Bracket Kit GFA24MIDV
(Residential use only) or
-
Stack and Feet Bracket Kit GFARVKITV
(Recreational Vehicle/Mobile Home
use only)

For alcove and closet depth and width
UHTXLUHPHQWVVHHVSHFL¿FNLWLQVWUXFWLRQV
Order on-line at GEApplianceparts.com
or by phone at 877.959.8688.
FOR THREE-WIRE SUPPLY
(208V & 240V MODELS)
• Remove terminal block cover.
&RQQHFWWZR+27OLQHVWRRXWHUVFUHZV/DQG/
of terminal block.
• Connect Neutral line to center
VFUHZ1RIWHUPLQDOEORFN
• Properly strain relief the cordset or cable to the cable
entry hole with UL recognized strain relief.
• Replace terminal block cover.
FOR FOUR-WIRE SUPPLY
(208V & 240V MODELS)
• Remove terminal block cover.
5HPRYHJURXQGVWUDSDQGGLVFDUG5HVFUHZJUHHQ
grounding screw in place.
&RQQHFWWZR+27OLQHVWRRXWHUVFUHZV/DQG/
of terminal block.
&RQQHFW1HXWUDOOLQHWRFHQWHUVFUHZ1RIWHUPLQDOEORFN
• Attach ground wire of power
supply to green grounding screw
beside terminal block.
• Properly strain relief the cordset or cable to the cable
entry hole with UL recognized strain relief.
• Replace terminal block cover.
Typical 30 amp receptacle for use where
local codes permit use of flexible type
power supply cord (pigtail).
3 WIRE RECEPTACLE
(10-30R)
•7KHRSHUDWLQJYROWDJH9ROWV$PSHUDJH$PSVDQG
)UHTXHQF\+]RIWKLVGU\HUDUHLQGLFDWHGRQWKH
Rating Plate located to the right of the loading port.
• Connect this dryer to a circuit corresponding to that
indicated on Rating Plate and protected by fuses or a
circuit breaker in accordance with local codes.
• Use a power supply cord kit marked for use with
FORWKHVGU\HU)RU9DQG9PRGHOVXVHDSRZHU
supply cord kit marked for use with clothes dryers.
)RUDOWHUQDWH9RU9SRZHUVXSSO\KRRNXS
SURFHHGDVIROORZV
• Connect supply wire leads to terminal block as shown
on sketch below, depending on type of installation.
• Make sure screws on terminal block are tight.
This appliance must be grounded. In the event of malfunction
or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electrical current.
WARNING Improper connection of the equipment
grounding conductor can result in a risk
RIHOHFWULFVKRFN&KHFNZLWKDTXDOL¿HGHOHFWULFLDQRU
serviceman if you are in doubt as to whether the appliance
is properly grounded.
'RQRWPRGLI\WKHSOXJSURYLGHGZLWKWKHDSSOLDQFHLILW
ZLOOQRW¿WWKHRXWOHWKDYHDSURSHURXWOHWLQVWDOOHGE\D
TXDOL¿HGHOHFWULFLDQ
WARNING
Appliance grounded to neutral conductor
through a link. If used in a mobile home,
a new construction, a recreational vehicle or if local codes do
QRWSHUPLWJURXQGLQJWKURXJKQHXWUDODFRQGXFWRUFRUGRU
cable assembly for use with clothes dryers must be used with
WKHIROORZLQJVSHFL¿FDWLRQV7\SH6W&DEOH0LQ
9ROW$PSZLWKFORVHGORRSWHUPLQDOVDQGVHFXUHGZLWKD
UL recognized strain relief. See manufacturer’s instructions.

ELECTRICAL CONNECTION DETAILS
OBSERVE ALL GOVERNING CODES AND ORDINANCES
DO NOT USE EXTENSION CORD WITH THIS
APPLIANCE
GROUNDING INSTRUCTIONS
POWER SUPPLY
&25'$:*
MINIMUM COPPER
&21'8&7256$03
9:,7+&/26('
LOOP TERMINALS
TYPE UL RECOGNIZED
0,1,0805$7('&
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
REMOVE GROUND STRAP
$1'',6&$5'25
92/723(5$7,21
2592/76833/<
86(21/<$03)86(6
POWER SUPPLY
&25'
AWG MINIMUM
COPPER
CONDUCTORS
$039
WITH TYPE UL
RECOGNIZED
MINIMUM RATED
&
2592/7
OPERATION
25
92/7
6833/<86(
21/<$03
)86(6
Hot Wire
Green
Ground
Screw
Ground
Strap
White Neutral Wire
Hot Wire
Green or Yellow
Ground Wire
Green Grounding Screw
Hot
Wire
White Neutral Wire
Hot
Wire
FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED.
Typical 30 amp receptacle for use
where local codes permit use of
flexible type power supply cord (pigtail).
Typical 30 amp cord assembly for
use where local codes do not
permit grounding through neutral.
4-WIRE RECEPTACLE (14-30R)
4-CONDUCTOR CORD
ASSEMBLY (Type ST Cable)
X
W
G
Y
IF YOUR DRYER COMES WITH REAR EXHAUST,
TO CHANGE TO SIDE OR BOTTOM EXHAUST:
• Remove access panel at back of dryer to gain access
to internal ducts.
• Disconnect duct exhaust from blower housing
UHPRYHWDSHVHFXULQJGXFW
FOR SIDE EXHAUST:
5HPRYHGHVLUHGNQRFNRXWSODWHHLWKHUULJKWRUOHIWVLGH
&XWDPPò´OHQJWKRIPP´GLDULJLG
GXFWDVVKRZQUHPRYHEXUUVIURPFXWHGJH
• Attach this extension duct to blower housing duct.
$WWDFKDHOERZIDFLQJGHVLUHGRSHQLQJ
$WWDFKDVHFWLRQRIPP´GLDULJLGGXFWWRHOERZ
to protrude through side of cabinet.
• Seal all joints with aluminum foil tape.
• Reinstall rear access panel.
FOR BOTTOM EXHAUST:
• Remove cover plate at bottom of dryer.
,QVWDOODHOERZ
• Seal all joints with aluminum foil tape.
• Reinstall rear access panel.
3ODFHFRYHUSODWHUHPRYHGIURPERWWRP
RIGU\HURYHUUHDUH[KDXVWRSHQLQJ
IF YOUR DRYER COMES WITH TOP EXHAUST,
TO CHANGE TO SIDE OR REAR EXHAUST:
• Remove rear access panel.
'LVFRQQHFWUHWDLQLQJSODWHDQGHOERZE\UHPRYLQJ
mounting screw from the chassis and remove tape
securing elbow to blower housing.
• Remove cover plate from rear access panel and place
over top exhaust opening.
FOR SIDE EXHAUST:
5HPRYHGHVLUHGNQRFNRXWSODWHHLWKHUULJKWRUOHIWVLGH
7DNHWKHGXFWSUHYLRXVO\UHPRYHGDQGFXWDPP
ò´OHQJWKRIPP´GLDULJLGGXFWDVVKRZQ
UHPRYHEXUUVIURPFXWHGJH
• Attach this extension duct to blower housing duct.
$WWDFKWKHHOERZIDFLQJGHVLUHGRSHQLQJ
$WWDFKDVHFWLRQRIPP´GLDULJLGGXFWWRHOERZ
to protrude through side of cabinet.
• Seal all joints with aluminum foil tape.
• Reinstall rear access panel.
FOR REAR EXHAUST:
&XWDPPò´OHQJWKRIPP´GLDULJLG
GXFWDVVKRZQUHPRYHEXUUVIURPFXWHGJH
• Attach this extension duct to blower housing.
•
Seal all joints with aluminum foil tape.
•
Reinstall rear access panel.

EXHAUST INFORMATION
WARNING IN CANADA AND IN THE UNITED
STATES, THE REQUIRED
EXHAUST DUCT DIAMETER IS 4 in (102mm).
DO NOT USE DUCT LONGER THAN SPECIFIED IN
THE EXHAUST LENGTH TABLE.
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
• Increase the drying times and the energy cost.
• Reduce the dryer life.
$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
WARNING BEFORE PERFORMING THIS
EXHAUST INSTALLATION, BE
SURE TO DISCONNECT THE DRYER FROM ITS
ELECTRICAL SUPPLY.
The correct exhaust installation is YOUR RESPONSIBILITY. Problems
due to incorrect installation are not covered by the warranty.
Remove and discard existing plastic or metal foil transition duct
DQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQGXFW
The MAXIMUM ALLOWABLE duct length and number of bends
of the exhaust system depends upon the type of duct, number
RIWXUQVWKHW\SHRIH[KDXVWKRRGZDOOFDSDQGDOOFRQGLWLRQV
noted below. The maximum duct length for rigid metal duct is
shown in the table on the next page.
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
• Terminate in a manner to prevent back drafts or entry of birds or
other wildlife.
• Termination should present minimal resistance to the exhaust air
ÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFHWRSUHYHQWFORJJLQJ
• Never install a screen in or over the exhaust duct. This could
cause lint build up.
•
:DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQGOHYHORUDQ\
other obstruction with the opening pointed down.
SEPARATION OF TURNS
For best performance, separate all turns by at least 4 ft. of straight
duct, including distance between last turn and exhaust hood.
TURNS OTHER THAN 90º
 2QHWXUQRIRUOHVVPD\EHLJQRUHG
 7ZRWXUQVVKRXOGEHWUHDWHGDVRQHWXUQ
 (DFKWXUQRYHUVKRXOGEHWUHDWHGDVRQHWXUQ
SEALING OF JOINTS
• All joints should be tight to avoid leaks. The male end of each
section of duct must point away from the dryer.
• The duct shall not be assembled with screws or other fastening
means that extend into the duct and catch lint.
 'XFWMRLQWVFDQEHPDGHDLUDQGPRLVWXUHWLJKWE\ZUDSSLQJWKH
overlapped joints with aluminum foil tape.
• Horizontal runs should slope down toward the outdoors 
inch per foot.
INSULATION
Ductwork that runs through an unheated area or is near air conditioning
VKRXOGEHLQVXODWHGWRUHGXFHFRQGHQVDWLRQDQGOLQWEXLOGXS
EXHAUST CONNECTION
WARNING TO REDUCE THE RISK OF FIRE
OR PERSONAL INJURY:
•
This clothes dryer must be exhausted to the outdoors.
• Use only 4” rigid metal ducting for the home exhaust duct.
8VH RQO\´ULJLGPHWDORU8/OLVWHGÀH[LEOHPHWDO VHPLULJLGRU
IRLOW\SH GXFW WR FRQQHFW WKH GU\HU WR WKH KRPH H[KDXVW GXFW
It must be installed in accordance with the instructions found in
“Connecting the Dryer to House Vent” on page 4 of this manual.
• Do not terminate exhaust in a chimney, a wall, a ceiling, gas
YHQW FUDZO VSDFH DWWLF XQGHU DQ HQFORVHG ÀRRU RU LQ DQ\
other concealed space of a building. The accumulated lint
FRXOGFUHDWHDSRWHQWLDO¿UHKD]DUG
• Never terminate the exhaust into a common duct with a kitchen
exhaust system. A combination of grease and lint creates a
SRWHQWLDO¿UHKD]DUG
'R QRW XVH GXFW ORQJHU WKDQ VSHFL¿HG LQ WKH H[KDXVW OHQJWK
table. Longer ducts can accumulate lint, creating a potential
¿UHKD]DUG
• Never install a screen in or over the exhaust duct. This will
FDXVHOLQWWRDFFXPXODWHFUHDWLQJDSRWHQWLDO¿UHKD]DUG
• Do not assemble ductwork with any fasteners that extend
into the duct. These fasteners can accumulate lint, creating a
SRWHQWLDO¿UHKD]DUG
• Do not obstruct incoming or exhausted air.
• Provide an access for inspection and cleaning of the exhaust
system, especially at turns and joints. Exhaust system shall be
inspected and cleaned at least once a year.
ALTERNATE EXHAUST INSTRUCTIONS
DRYER TOP VIEW
Left knockout
Bottom
knockout
Right knockout
Blower
Front of dryer
152
mm
203 mm
(8”)
89 mm
(3½”)
6”
For Rear Exhaust
For Side Exhaust
Rigid
Metallic
Ducting
Cut Here
EXTENSION DUCT
It is importat to replace the ground clip after
cuttin
g
the exhaust duct,
(
on rear exhaust model
)
295 mm
115 mm (4½”)
(11½”)
EXHAUST LENGTH CALCULATION
RIGID (Preferred)
3DUWVDUHDYDLODEOHIURP\RXUORFDOVHUYLFHRUJDQL]DWLRQ
:;;´;¶'XFW :;;(OERZ
:;;´;¶'XFW :;;$OXPLQXPKRRG
4
ALCOVE OR CLOSET INSTALLATION
• If your dryer is approved for installation in an alcove or
closet, it will be stated on a label on the dryer back. The
LQVWDOODWLRQPXVWFRQIRUPWRWKHIROORZLQJVSHFL¿FDWLRQV
WARNING TO PREVENT LARGE
AMOUNTS OF LINT AND
MOISTURE FROM ACCUMULATING AND TO
MAINTAIN DRYER EFFICIENCY, THIS
MACHINE MUST BE EXHAUSTED OUTDOORS.
• Minimum clearances between dryer cabinet and
DGMDFHQWZDOOVRURWKHUVXUIDFHVDUH
0LQLPXPYHUWLFDOVSDFHIURPÀRRUWRRYHUKHDGFDELQHWV
FHLOLQJHWFLVLQ
• Closet doors must be louvered or otherwise ventilated
DQGPXVWFRQWDLQDWOHDVWVTXDUHLQFKHVRIRSHQDUHD
equally distributed. If the closet contains both a washer
DQGDGU\HUGRRUVPXVWFRQWDLQDWOHDVWVTXDUHLQFKHV
of open area equally distributed.
NOTE TO INSTALLER - AFTER INSTALLATION
CHECK THE FOLLOWING:
(;+$867'8&70XVWPHHWVSHFVRQSDJH1R
H[FHVVLYHWXUQV1RNLQNVRUREVWUXFWLRQVWRDLUÀRZ
(;+$867+22'6KRXOGZRUNIUHHO\DQGRSHQGRZQZDUG
*5281',1*'U\HUPXVWEHSURSHUO\JURXQGHGWRFRQIRUP
to local codes and ordinance requirements.
23(5$7,217XUQGU\HURQDQGFKHFNIRUKHDW
+$1'&86720(57+(2:1(5¶60$18$/*LYH
LQVWUXFWLRQVRQRSHUDWLQJWKHGU\HU$QVZHUDQ\TXHVWLRQV

GIVE THESE INSTALLATION INSTRUCTIONS to the customer.
4" DIA.
4"
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90°
Elbows
Rigid
Metal
Rigid
Metal
14 m (46 ft)
11 m (37 ft)
9 m (30 ft)
7 m (23 ft)
11 m (37 ft)
9 m (30 ft)
6.5 m (22 ft)
4.5 m (15 ft)
0
1
2
3
Use only for short
run installations
CONNECTING THE DRYER TO HOUSE VENT
RIGID METAL TRANSITION DUCT
• For best drying performance, a rigid metal transition duct
is recommended.
• Rigid metal transition ducts reduce the risk of crushing
and kinking.
UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION
DUCT
,IULJLGPHWDOGXFWFDQQRWEHXVHGWKHQ8/OLVWHGÀH[LEOH
PHWDOVHPLULJLGGXFWLQJFDQEHXVHG.LW:;;
1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU
other enclosed spaces.
 7RWDO OHQJWK RI ÀH[LEOH PHWDO GXFW VKRXOG QRW H[FHHG 
feet.
• For many applications, installing elbows at both the dryer
DQG WKH ZDOO LV KLJKO\ UHFRPPHQGHG VHH LOOXVWUDWLRQV
EHORZ (OERZV DOORZ WKH GU\HU WR VLW FORVH WR WKH ZDOO
without kinking and or crushing the transition duct,
maximizing drying performance.
• Avoid resting the duct on sharp objects.
UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION
DUCT
• In special installations, it may be necessary to connect the
GU\HU WR WKH KRXVH YHQW XVLQJ D ÀH[LEOH PHWDO IRLO W\SH
GXFW $ 8/OLVWHG ÀH[LEOH PHWDO IRLOW\SH GXFW PD\ EH
XVHG 21/< LQ LQVWDOODWLRQV ZKHUH ULJLG PHWDO RU ÀH[LEOH
PHWDOVHPLULJLGGXFWLQJFDQQRWEHXVHG$1'ZKHUHD´
diameter can be maintained throughout the entire length of
the transition duct.
,Q&DQDGDDQGWKH8QLWHG6WDWHVRQO\WKHÀH[LEOHPHWDO
IRLOW\SHGXFWVWKDWFRPSO\ZLWKWKH³2XWOLQHIRU&ORWKHV
'U\HU7UDQVLWLRQ'XFW6XEMHFW$´VKDOOEHXVHG
1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU
other enclosed spaces.
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHW
• Avoid resting the duct on sharp objects.
For best drying performance
6OLGHRQHHQGRIGXFWRYHUWKHFORWKHVGU\HURXWOHWSLSH
6HFXUHWKHGXFWZLWKDFODPS
:LWKWKHGU\HULQLWVSHUPDQHQWSRVLWLRQH[WHQGWKHGXFW
WRLWVIXOOOHQJWK$OORZ´RIGXFWWRRYHUODSWKHH[KDXVW
SLSH&XWRႇDQGUHPRYHH[FHVVGXFW.HHSWKHGXFWDV
VWUDLJKWDVSRVVLEOHIRUPD[LPXPDLUÀRZ
4.Secure the duct to the exhaust pipe with the other clamp.
NOTE: The clearances stated above are minimums.
Consideration must be given to the type accessory
NLWXVHGZLWKGU\HU5HIHUWRWKHVSHFL¿FNLW
instruction for details.
Alcove Closet
Sides 0” ´
Top ´ ´
Front ´
Rear ´ ´
WHEN INSTALLED IN MANUFACTURED (MOBILE) HOMES
Dryer must be exhausted to the outside. Exhaust MUST NOT be
terminated beneath mobile home. Exhaust material MUST NOT
support combustion. Installation MUST conform to Manufactured
+RPH&RQVWUXFWLRQ6DIHW\6WDQGDUG7LWOH&)53DUW
or when such standard is not applicable, the American National
6WDQGDUGRI0RELOH+RPHV$16,1)5$1R%)RU
electrical connection, see “Connecting dryer using 4 wire connection”.
USE OF CASTERS (120V PORTABLE MODELS ONLY)
For a portable installation screw casters into the holes on the bottom
of the dryer. Refer to the “Installation Instructions for caster assembly”
sheet to install casters.
• )RU HYHU\ H[WUD  HOERZ UHGXFH WKH DOORZDEOH YHQW V\VWHP
OHQJWKE\IW
• 7ZRHOERZVZLOOEHWUHDWHGOLNHRQHHOERZ
• )RUWKHVLGHH[KDXVWLQVWDOODWLRQVDGGRQHHOERZWRWKHFKDUW
• The total vent system length includes all the straight portions and
HOERZVRIWKHV\VWHPWUDQVLWLRQGXFWLQFOXGHG
FLEXIBLE
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKDOOQRWH[FHHGIWP7KH
IROORZLQJNLWLVDYDLODEOHIURP\RXORFDOVHUYLFHRUJDQL]DWLRQ
.LW :;;  ´ GLD ÀH[LEOH PHWDO VHPLULJLG 8/OLVWHG
WUDQVLWLRQGXFWLQFOXGHVHOERZV

This manual suits for next models

1

Other GE Dryer manuals

GE Profile Harmony DPGT750ECPL Operating instructions

GE

GE Profile Harmony DPGT750ECPL Operating instructions

GE Model 591 User manual

GE

GE Model 591 User manual

GE DPSB620EC Manual

GE

GE DPSB620EC Manual

GE DCB330 and Operating instructions

GE

GE DCB330 and Operating instructions

GE DMCD330EH Manual

GE

GE DMCD330EH Manual

GE GFDS260EFWW Manual

GE

GE GFDS260EFWW Manual

GE GTD65EBMR User manual

GE

GE GTD65EBMR User manual

GE GTDN500GM Manual

GE

GE GTDN500GM Manual

GE GTDP220EFWW User manual

GE

GE GTDP220EFWW User manual

GE Profile DPSB613 User manual

GE

GE Profile DPSB613 User manual

GE GFDS175 User manual

GE

GE GFDS175 User manual

GE DISR473CG5WW User manual

GE

GE DISR473CG5WW User manual

GE GTD84ECPNDG User manual

GE

GE GTD84ECPNDG User manual

GE DBVH510GH Manual

GE

GE DBVH510GH Manual

GE DDG5886M User manual

GE

GE DDG5886M User manual

GE DWSR483GG Manual

GE

GE DWSR483GG Manual

GE DDE8200G User manual

GE

GE DDE8200G User manual

GE Profile DPSE810GG Manual

GE

GE Profile DPSE810GG Manual

GE DCB330EY How to use

GE

GE DCB330EY How to use

GE 175D1807P241 User manual

GE

GE 175D1807P241 User manual

GE GTX42EASJWW User manual

GE

GE GTX42EASJWW User manual

GE CleanSpeak GTD81ESPJMC User manual

GE

GE CleanSpeak GTD81ESPJMC User manual

GE DNCD450EGBWC User manual

GE

GE DNCD450EGBWC User manual

GE DCCD330GD User manual

GE

GE DCCD330GD User manual

Popular Dryer manuals by other brands

Indesit IDV 75 manual

Indesit

Indesit IDV 75 manual

Frigidaire FFSE5115PA Installation

Frigidaire

Frigidaire FFSE5115PA Installation

Bosch WTR87TW2CS Installation and operating instructions

Bosch

Bosch WTR87TW2CS Installation and operating instructions

EUROM LO 20 instruction manual

EUROM

EUROM LO 20 instruction manual

timblau TIM-021099 quick start guide

timblau

timblau TIM-021099 quick start guide

Tappan TDG336RE operating instructions

Tappan

Tappan TDG336RE operating instructions

Parkinson Cowan 45 GT Instruction book

Parkinson Cowan

Parkinson Cowan 45 GT Instruction book

Speed Queen LES37 specification

Speed Queen

Speed Queen LES37 specification

Siemens Dryer Operating and installation instructions

Siemens

Siemens Dryer Operating and installation instructions

Maytag MDE2400AZW installation instructions

Maytag

Maytag MDE2400AZW installation instructions

Frigidaire GLER341AS2 installation instructions

Frigidaire

Frigidaire GLER341AS2 installation instructions

LG DLEX3570 series owner's manual

LG

LG DLEX3570 series owner's manual

Gorenje D722CM How to use

Gorenje

Gorenje D722CM How to use

Hanseatic HKT8BGT2 user manual

Hanseatic

Hanseatic HKT8BGT2 user manual

Frigidaire FAQe7011K W/B Specifications

Frigidaire

Frigidaire FAQe7011K W/B Specifications

Whirlpool 3LWED4900YW manual

Whirlpool

Whirlpool 3LWED4900YW manual

Whirlpool cabrio WED6200S user manual

Whirlpool

Whirlpool cabrio WED6200S user manual

Bosch WTN86205TH Installation and operating instructions

Bosch

Bosch WTN86205TH Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.