GE Interlogix 0150-0265A User manual

0150-0265A
ProBridge Gateway
1
2
V
D
C
RS-232
PORT2
RS-485
PORT 0
RS-232 / RS-485
PORT 1
RS-485 SEL
RS-232 SEL
TERM1
BIAS1-
BIAS1+
TERM0
BIAS0-
BIAS0+
PORT 0 PORT 1
8
7
6
5
4
3
2
1
O
F
F
O
N
8
7
6
5
4
3
2
1
O
F
F
O
N
87654321
O
F
F
O
N
87654321
O
F
F
O
N
SW1
SW2
SW3
SW4
Kalatel Pro Bridge
e

© 2003 Kalatel, a GE Interlogix company
All Rights Reserved.
Any GE Interlogix, Kalatel division, software
supplied with GE Interlogix, Kalatel division,
products is proprietary and furnished under
license and can be used or copied only in
accordance with the terms of such license.
This document contains proprietary
information that is protected by copyright. No
part of this document may be reproduced or
transmitted in any form or by any means
without the prior written permission of GE
Interlogix, Kalatel division.
The information contained in this document is
subject to change without notice. GE
Interlogix, Kalatel division, in keeping pace
with technological advances, is a company of
product innovation. Therefore, it is difficult to
ensure that all information provided is entirely
accurate and up-to-date. GE Interlogix, Kalatel
division, accepts no responsibility for
inaccuracies or omissions and specifically
disclaims any liabilities, losses, or risks,
personal or otherwise, incurred as a
consequence, directly or indirectly, of the use
or application of any of the contents of this
document.
For the latest product specifications, visit GE
Interlogix, Kalatel division, online at
www.kalatel.com or contact your Kalatel sales
representative.
For technical support before and after
installation, call 800-469-1676.
Technical support is available 24 hours a day, 7 days
a week.
Call: Tech Support 800-469-1676 (6 A.M. –5 P.M. PST Monday through Friday)
Tech Support 541-740-3589 (all other times)
Main 800-343-3358 or 541-754-9133
Fax: Tech Support 541-752-9096 (available 24 hours a day)
Main 541-754-7162
Web: www.kalatel.com
0150-0265A / August 2003
This equipment has been tested and
found to comply with the limits for a
Class A digital device, pursuant to part
15 of the FCC Rules. These limits are
designed to provide reasonable
protection against harmful interference
when the equipment is operated in a
commercial environment. This
equipment generates, uses, and can
radiate radio frequency energy and, if
not installed and used in accordance
with the instruction manual, may cause
harmful interference to radio
communications.
You are cautioned that any changes or
modifications not expressly approved
by the party responsible for compliance
could void the user's authority to
operate the equipment.

ProBridge Gateway
Table of Contents
0150-0265A / August 2003 3
TABLE OF CONTENTS
BEFORE YOU BEGIN ...............................................................4
1OVERVIEW .......................................................................5
1.1 PROBRIDGE GATEWAY COMPONENTS:.......................5
1.1.1 Installation Environment.............................................5
1.2 POWER....................................................................6
1.3 PROBRIDGE GATEWAY PRODUCT DIAGRAM................7
1.3.1 Dipswitch Position Legend.........................................7
2PROGRAMMING MODE.......................................................8
3OPERATING MODE............................................................9
4OPERATION....................................................................10
4.1 MESSAGE TRANSLATION FROM LEGACY (IMPAC) RS485
NETWORK TO THE KALATEL RS485 NETWORK:..........10
4.1.1 Addressing .............................................................. 10
4.1.2 Preset:..................................................................... 10
4.1.3 Movement Speed:.................................................... 11
4.2 MESSAGE TRANSLATION FROM KALATEL RS485
NETWORK TO LEGACY (IMPAC) RS485 NETWORK:.....13
5CABLE SPECIFICATIONS..................................................14
5.1 PROBRIDGE TO DVMRE TRIPLEX CABLE..................14
5.2 PROBRIDGE TO PC/LAPTOP CABLE..........................14
5.3 PROBRIDGE TO I/O JUNCTION BOX..........................15
6SPECIFICATIONS.............................................................16
WARRANTY AND RETURN INFORMATION.................................17

GE Interlogix
ProBridge Gateway
40150-0265A / August 2003
BEFORE YOU BEGIN
Read these instructions before installing or operating this product.
Note: This installation should be made by a qualified service person and should conform to
local codes.
This manual provides installation and operation information. To use this
document, you must have the following minimum qualifications:
•A basic knowledge of CCTV systems and components
•A basic knowledge of electrical wiring and low-voltage electrical
hookups
Use this product only for the purpose for which it was designed.
Customer Support
For assistance in installing, operating, maintaining, and troubleshooting
this product, refer to this document and any other documentation
provided. If you still have questions, contact Kalatel Technical Support:
GE Interlogix, Kalatel division
Call: 800-469-1676
Fax: 541-752-9096
Note: You should be at the equipment, ready with details before calling Technical Support.
Conventions Used in this Manual
Boldface or button icons highlight command entries. The following
WARNING,CAUTION,and Note statements identify potential hazards:
* WARNING:
Improper use of this equipment can cause severe bodily injury or
equipment damage.
** CAUTION:
Improper use of this equipment can cause equipment damage.
Note: Notes contain important information about a product or procedure.
* This symbol indicates electrical warnings and cautions.
** This symbol indicates general warnings and cautions.

ProBridge Gateway
GE Interlogix
0150-0265A / August 2003 5
1OVERVIEW
The ProBridge Gateway is a product specific ProBridge translator that converts
RS485 messages between a legacy (IMPAC) RS485 network and a Kalatel
RS485 network. Its main purpose is to act as a router between a network that
uses zone addressing and a network that uses direct camera addressing. This
allows systems to utilize PTZ camera control over the TCP/IP connection with
WaveReader in systems that use camera addressing based on matrix switcher
input numbers. This product is a derivative of the standard PB3 Protocol
Converter product.
The ProBridge Gateway has the following two modes of operation:
•The Programming mode
•The Operating mode
In the Programming mode the installer can set up the mapping between
cameras assigned to multiplexers/ DVMRe products and dome cameras. This
allows for totally arbitrary camera mapping, i.e. DVMRe 5, camera 14 can be
mapped to camera number 983.
In the Operating mode the ProBridge Gateway will translate messages to ensure
that telemetry messages originating from Mux/DVMRe products will correctly
address the intended dome.
1.1 PROBRIDGE GATEWAY COMPONENTS:
The ProBridge Gateway product includes:
(1) CBR-PB3-GW ProBridge unit.
(1) P/N 4310-0034B: RJ45 to RJ45 cable. Connects the ProBridge Gateway
RS485 Port 0 to the DVMRe Triplex RS485 port. This cable is 6’ in length.
(1) P/N 4310-0047B: RJ45 to DB9F cable. Connects the ProBridge Gateway to
RS232 Port 1 to a PC or Notebook for programming. This cable is 6’ in length.
(1) P/N 4310-0032A: RJ45 to flying leads cable. Connects the ProBridge
Gateway to the KTD-405 Keyboard and the dome cameras through the I/O
junction box. This cable is 6’ in length.
(1) P/N 4010-0007: 12VDC 120VAC Power Supply or P/N 4010-0008: 12VDC
220VAC Power Supply.
(1) P/N 0150-0265A: ProBridge Gateway User Manual.
1.1.1 INSTALLATION ENVIRONMENT
Power: Ensure that the installation site’s AC power is stable and within the rated
voltage of the external power supply. If the site’s AC power is likely to have
spikes or dips, use power line conditioning or an Uninterruptible Power Supply.

GE Interlogix
ProBridge Gateway
60150-0265A / August 2003
Temperature: Observe the unit’s ambient temperature specifications when
choosing a location for the unit. Extremes of heat or cold beyond the specified
operating temperature limits may cause the unit to fail. Do not install this unit on
top of other hot equipment.
Moisture: Do not expose the unit to rain or moisture. Moisture can damage
internal components. Do not install this unit near sources of water.
RS-232 Limitations: Cable length between the POS device and the ProBridge
is limited to 50’. Cable length between the ProBridge unit and the DVMRe is also
limited to 50’. If the supplied cables are replaced by custom made cables to
address distances between components, ensure the cable is manufactured to
ANSI standards for RS-232 communication.
RS485 Limitations: If multiple PB3 units are connected to a single DVMRe unit,
the distance between the first and last ProBridge unit is limited to 3,000 feet (RS-
485 communications).
1.2 POWER
The ProBridge is furnished with a power supply (110 or 240 VAC). Do not use
any other power supply with this product. The manufacturer accepts no
responsibility for damage caused by the use of any other power supply.
Make sure installation is complete and all connections are made before applying
power to the unit.
4310-0007: 120VAC Power Supply
Power Supply Input
Voltage: 120 Volt AC
Tolerance: ±10%
Frequency: 60 Hz
Power Supply Output
Voltage: 12 Volt DC
Current: 110mA
Power: 1.3 Watts
Connector: 2.1mm female barrel. Center Positive

ProBridge Gateway
GE Interlogix
0150-0265A / August 2003 7
4310-0008: 220VAC Power Supply
Power Supply Input
Voltage: 220 Volt AC
Tolerance: ±10%
Frequency: 50 Hz
Power Supply Output
Voltage: 12 Volt DC
Current: 110mA
Power: 1.3 Watts
Connector: 2.1mm female barrel. Center Positive
1.3 PROBRIDGE GATEWAY PRODUCT DIAGRAM
48
7
6
5
3
2
1
6
5
123478
6
5
123478
6
5
123478
12V DCRS-232
PORT 2
RS-485
PORT0
RS-232/RS-485
PORT1
RS-485 SEL
RS-232 SEL
TERM 1
BIAS 1 -
BIAS 1 +
TERM 0
BIAS 0 -
BIAS 0 +
PORT
0PORT
1
8
7
6
5
4
3
2
1
O
F
F
O
N
8
7
6
5
4
3
2
1
O
F
F
O
N
8
7
6
5
4
3
2
1
O
F
F
O
N
8
7
6
5
4
3
2
1
O
F
F
O
N
SW1SW2S
W
3
S
W
4
K
a
l
a
t
e
l
P
r
o
B
r
i
d
g
e
e
SW1
Dipswitch 1-8
Port 2
RS232 Power Supply
Connector 12VDC
Port 1
RS232/RS485
Selectable
Port 0
RS485
Network Bus
SW2
Dipswitch 1-8
SW3
Dipswitch 1-8
SW4
Dipswitch 1-8
Note: Port 0 and Port 1 have looping RJ45 connectors.
1.3.1 DIPSWITCH POSITION LEGEND

GE Interlogix
ProBridge Gateway
80150-0265A / August 2003
2PROGRAMMING MODE
Setting the ProBridge Gateway to Programming mode:
•Set the device to programming mode by setting the dipswitch at SW4.
(SW4 RS232 SEL on, RS485 SEL off)
•Ensure the RS232 (4310-0047B) cable is connected from the PC or
Laptop to one of the port 1 connectors on the ProBridge Gateway.
•Open HyperTerminal on a laptop PC,
oSet the RS232 port to 9600, N, 8, 1. (File/Properties, “Connect
to” tab, “Configure” button)
oSet local echo on (File/Properties, “Settings” tab, “ASCII Setup”
button)
•Cycle power on the ProBridge Gateway box and follow the instructions
in HyperTerminal.
Connection Diagram for programming mode is shown below
12V DCRS-232
PORT 2
RS-485
PORT0
RS-232 /RS-485
PORT1
RS-485 SEL
RS-232 SEL
TERM 1
BIAS 1 -
BIAS 1 +
TERM 0
BIAS 0 -
BIAS 0 +
PORT0PORT1
87654321
O
F
F
O
N
87654321
O
F
F
O
N
87654321
O
F
F
O
N
87654321
O
F
F
O
N
SW1SW2SW3
SW4
KalatelP
r
o
B
r
i
d
g
e
e
ProBridge Gateway
RS232
DB9F
4310-0047B Cable
RJ45 (Port 1)
Notebook or PC
Running HyperTerminal (RS232)
for Programming

ProBridge Gateway
GE Interlogix
0150-0265A / August 2003 9
3OPERATING MODE
Setting the ProBridge Gateway in Operating mode:
•Set the device to operating mode by setting the dipswitch at SW4.
(SW4 RS232 SEL off, RS485 SEL on)
•Connect the devices and cables as shown below.
•Cycle power on the ProBridge Gateway box and the other devices.
Connection Diagram for Operating mode is shown below.
12V DC
RS-232
PORT 2
RS-485
PORT0
RS-232 /RS-485
PORT1
RS-485 SEL
RS-232 SEL
TERM 1
BIAS 1 -
BIAS 1 +
TERM 0
BIAS 0 -
BIAS 0 +
PORT0PORT1
87654321
O
F
F
O
N
87654321
O
F
F
O
N
87654321
O
F
F
O
N
87654321
O
F
F
O
N
SW1SW2SW3
SW4
KalatelProBridge
e
DVMRe Triplex
ProBridge Gateway
RJ45
TCP/IP
RS485
RS485
RS485
RS422
4310-0034B Cable
4310-0032A Cable
RJ45 (Port 0)
RJ45 (Port 1)
CyberDome Camera
I/O
Junction
Box
KTD-405
Notebook or PC
Running WaveReader (TCP/IP)
See Keyboard
Manual for
connection details

GE Interlogix
ProBridge Gateway
10 0150-0265A / August 2003
4OPERATION
4.1 MESSAGE TRANSLATION FROM LEGACY (IMPAC) RS485
NETWORK TO THE KALATEL RS485 NETWORK:
•Legacy (Impac) RS485 network (Multiplexers/DVMRe’s) is
referenced as Port 0 in the rest of this document.
•Kalatel RS485 network (KTD405 and domes) is referenced as Port
1 in the rest of this document.
•Only telemetry messages (type 0x09) are processed. All other
message types are passed through unchanged.
4.1.1 ADDRESSING
Kalatel domes can be addressed from 0000 up to 1023.
4.1.2 PRESET:
Port 0: Example with Set Preset and Go To Preset on WaveReader.
Set Preset: On drop down menu, select the preset number from preset menu
(1 to16). Click “Set” to set the preset.
Go To Preset: On the drop down menu, select the preset number from
preset 1 to16. Click “Go to” to recall that preset (Presets can also be generated
on Muxes that have advanced alarm handling capability). The DVMRe will
receive these preset messages via TCP/IP and convert them to RS485. They
will appear at port 0 in the following format:
Message format:
Synchronization 0xFF
Length 0x07
Message type 1 0x09
Message type 2 0x0A/0x0B (set preset/call preset)
Destination Impac Mux/DVMRe
Source Impac Mux/DVMRe
Camera number Camera connected to Mux/DVMRe (00-0F)
Preset number 0 to 15 (for preset 1 to 16)
Checksum 2’s complement
Port 1: Set Preset and Call Preset on the KTD405.
Message format:
Synchronization 0xFF
Length 0x07
Message type 1 0x20 Digiplex message
Message type 2 312 command code
CMD312_SET_PRESET(Q) / CMD312_FIND_PRESET(E)
Destination Mapped camera: 0x80-0xFD* 0x80 + camera # high byte
Source 0x00-0xFD keypad address <= Impac Mux/DVMRe

ProBridge Gateway
GE Interlogix
0150-0265A / August 2003 11
Camera number Mapped camera: Camera (site) # low byte
“Monitor “ value Preset number value 1 to 16 (for Preset 1 to 16)
(General command parameter)
Checksum 2’s complement
4.1.3 MOVEMENT SPEED:
4.1.3.1 PAN, TILT, AND ZOOM (PTZ)
WaveReader: Variable speed range 0 –15 (Pan & Tilt) based on variable Pan &
Tilt speed value from WaveReader, will be converted to range 1-32 on the
Kalatel RS485 network. (Zoom: fixed at 10 at Kalatel RS485 network)
Two messages are generated for controlling PTZ: Motor message and Variable
Speed message. The ProBridge Gateway combines these two into one message
as follows:
Port 0: Example with PTZ messages on WaveReader.
Motor Message format:
Synchronization 0xFF
Length 0x07
Message type 1 0x09
Message type 2 0x05
Destination Impac Mux/DVMRe
Source Impac Mux/DVMRe
Camera number Camera connected to Mux/DVMRe (00-0F)
Motor command Impac motor command
Checksum 2’s complement
Variable Speed Message format:
Synchronization 0xFF
Length 0x0B
Message type 1 0x09
Message type 2 0x0C
Destination Impac Mux/DVMRe
Source Impac Mux/DVMRe
Camera numberCamera connected to Mux/DVMRe (00-0F)
Pan speed Pan speed value
Tilt speed Tilt speed value
Zoom speed Zoom speed value
Focus speed Focus speed value
Iris speed Iris speed value
Checksum 2’s complement
Port 1: PTZ message at KTD405. Message type 1=0x09, Message type 2=0x14
Message format:
Synchronization 0xFF
Length 0x09
Message type 1 0x09 Telemetry message type 1
Message type 2 0x14 New PTZ packet
Destination 0x00-0xFD Zone = Destination + 1 (Mapped camera)

GE Interlogix
ProBridge Gateway
12 0150-0265A / August 2003
Source 0x00-0xFD keypad address <= Impac Mux/DVMRe
Camera number Mapped camera: 32 Cameras/Zone
Pan information 0x00: No Pan movement; 0x01 to 0x20: Pan Left at speed 1
to 32...
Tilt information 0x00: No Tilt movement; 0x01 to 0x20: Tilt Down at speed to
32...
Zoom information 0x00: No Zoom; 0x80+(0x01 to 0x20): Zoom In at speed 1 to
32...
Checksum 2’s complement
4.1.3.2 IRIS AND FOCUS (No Speed Values)
There is a motor start and motor stop command associated with each of the 4
functions to be controlled: Iris Open, Iris Close, Focus Near, Focus Far. A
message is generated each time one of these four keys are pressed or released.
The ProBridge Gateway converts these messages to 312 messages as follows:
Port 0: Example with Iris Close (Start) on WaveReader
Motor Message format:
Synchronization 0xFF
Length 0x07
Message type 1 0x09
Message type 2 0x05
Destination Impac Mux/DVMRe
Source Impac Mux/DVMRe
Camera number Camera connected to Mux/DVMRe (00-0F)
Motor command Iris Close Start (Impac motor command)
Checksum 2’s complement
Port 1: Iris, Focus message at KTD405
Message format:
Synchronization 0xFF
Length 0x07
Message type 1 0x20 Digiplex message
Message type 2 312 command code
CMD312_IRIS_CLOSE(C) (Start)
Destination Mapped camera: 0x80-0xFD* 0x80 + camera # high byte
Source 0x00-0xFD keypad address <= Impac Mux/DVMRe
Camera number Mapped camera: Camera (site) # low byte
“Monitor “ value 0 (General command parameter)
Checksum 2’s complement
4.1.3.3 MOUSETRAK COMMAND:
Mapped address only. Nothing else has been changed.
4.1.3.4 AUX:
Not available at this time.

ProBridge Gateway
GE Interlogix
0150-0265A / August 2003 13
4.2 MESSAGE TRANSLATION FROM KALATEL RS485
NETWORK TO LEGACY (IMPAC) RS485 NETWORK:
All messages are passed through unchanged (transparent), with the exception of
Kalatel Menu Mode messages, which are blocked. (Message types 0x08, 0x09,
0x10, 0x11, 0x12, 0x13 and 0x14 are passed through)

GE Interlogix
ProBridge Gateway
14 0150-0265A / August 2003
5CABLE SPECIFICATIONS
5.1 PROBRIDGE TO DVMRE TRIPLEX CABLE
Part Number : 4310-0034B
Communication Type: RS485
Connector Type: RJ-45, RJ-45
Cable Required: 5 Foot RJ-45 to RJ-45
Triplex RS485 Cable (Supplied).
Connects ProBridge to DVMRe-CT.
RJ-45
RJ-45
Connector
Connector
Pin 8: Brown
Pin 7: Brown/White
Pin 6: Green
Pin 5: Blue/White
Pin 4: Blue
Pin 3: Green/White
Pin 2: Orange
Pin 1: Orange/White
Pin 8: Brown
Pin 7: Brown/White
Pin 6: Green
Pin 5: Blue/White
Pin 4: Blue
Pin 3: Green/White
Pin 2: Orange
Pin 1: Orange/White
RJ-45 Connector RJ-45 Connector
5.2 PROBRIDGE TO PC/LAPTOP CABLE
Part Number : 4310-0047B
Communication Type: RS232
Connector Type: RJ-45 ,DB9F
Cable Required: 6 Foot RJ-45 to DB9F
RS232 Cable (Supplied). Connects
ProBridge to the serial port of a PC or
Laptop computer.
NOTE: This cable is used for Programming
ProBridge via Windows HyperTerminal
Pin 8
Pin 7
Pin 6
Pin 5
Pin 4
Pin 3
Pin 2
Pin 1
RJ-45
Connector
DB-9F
Connector
Pin 8
Pin 7
Pin 6
Pin 5
Pin 4
Pin 3
Pin 2
Pin 1
Pin 9
RJ-45 Connector DB9F Connector

ProBridge Gateway
GE Interlogix
0150-0265A / August 2003 15
5.3 PROBRIDGE TO I/O JUNCTION BOX
Part Number : 4310-0032A
Communication Type: RS485
Connector Type: RJ45, Flying Leads
Cable Required: RS-485 Flying Leads
Cable. Interconnects ProBridge with
KTD-405 and Dome Cameras.
Pin 8
Pin 7
Pin 6
Pin 5
Pin 4
Pin 3
Pin 2
Pin 1
RJ-45
Flying
Leads
Black
Red
Connector
RJ45 Connector Flying Leads

GE Interlogix
ProBridge Gateway
16 0150-0265A / August 2003
6SPECIFICATIONS
Physical
Housing Metal enclosure.
Dimensions
(W x L x H) 4.0” x7.0” x1.0”. (100mm x
175mm x25 mm)
Nominal Weight 4.8 oz (136 g)
Shipping Weight 1 lb (453 g) packaged, including
the external AC power supply and
manual.
Color Black.
Environmental
Temperature 0 to 40 °C, operating.
Relative Humidity 90%, non-condensing.
Electrical
AC Power External AC power supply included.
Voltage Range: 110 to 240 VAC +10%
Current: 200 mA
DC Power DC jack, positive center.
Power Supply Voltage: 12 VDC
Current: 110 mA
Power: 1.5 W
Note: All specifications are subject to change without notice. Kalatel believes that all
specifications are correct, however no liability is assumed for omissions or errors.

ProBridge Gateway
GE Interlogix
0150-0265A / August 2003 17
WARRANTY AND RETURN INFORMATION
GE Interlogix, Kalatel division, warrants its equipment for three years
from the date of purchase. This warranty covers defects in materials and
workmanship only; equipment failures that are due to improper
installation, modification, abuse, or acts of nature are not covered by this
warranty. The repair department will evaluate all equipment returned for
repair to determine warranty coverage. The Tech Support Manager will
resolve any questions that may arise during evaluation to make a final
determination.
Note: The three-year warranty does not apply to the following products:
MobileView®and the monitor CRT, which carry a 12-month warranty from the date of
purchase.
For all warranty repairs, GE Interlogix, Kalatel division, will cover all
costs, including parts, labor, and shipping. Repaired equipment will be
returned via the same method of shipment in which it was received. If a
customer requests a faster return shipment, the difference will be
charged.
For all non-warranty repairs, the customer will be billed for parts, labor,
and shipping. Labor will be billed in half-hour increments.
Note: Customers requesting an estimate prior to repair will be notified by phone. If they
cannot be reached, they will be notified by fax. If we are unable to reach the contact person
for repair authorization after one phone attempt and two fax attempts, the equipment will be
returned without being repaired. We will hold equipment no longer than two weeks.
ADVANCE REPLACEMENT POLICY
When an advance replacement is required, we will send the customer
replacement equipment from our stock and receive the returned product
in exchange. The received equipment will be evaluated and the repair
department will determine whether it is a warranty replacement. If it is
non-warranty, see our repair policy above for details. The following
guidelines will be used for all advance replacements:
•Fewer than 45 days from purchase, GE Interlogix, Kalatel division,
will replace the product with new equipment.
•From 45 days to 1 year from purchase, GE Interlogix, Kalatel
division, will replace the product with refurbished equipment.
•From 1 year to 3 years from purchase, the product must be sent in
for repair. Advance replacements will be sent for a fee of $100.
If you have questions about this policy, please contact Kalatel’s RMA
department at 800-469-1676.

Table of contents
Other GE Gateway manuals

GE
GE 3500/91 EGD User manual

GE
GE POWER LEADER GEH-6505A User manual

GE
GE GCG001 User manual

GE
GE Multilin D400 User manual

GE
GE GFK-2892F User manual

GE
GE Multilin D400 Instructions for use

GE
GE ProBridge User manual

GE
GE PACSystems RX3i Genius User manual

GE
GE NX-592E-GSM User manual

GE
GE MDS WiYZ User manual