GE RHM 15 User manual

RHM 15
The RHM 15 can measure ow rates up to 200 kg/
min (440 lb/min) with temperatures in excess of
350°C and pressures up to 540 bar. This model
is truly a reliable solution, manufactured by GE’s
Rheonik mass owmeter experts.
Applications
Used in industry for ow measurement applications
requiring high mass ow accuracy.
• General control • Dosing • Mixing
• Batching • Injections • Filling
Features
• Suitable for pressure up to 540 bar
• Flow uncertainty down to 0.12%
• Density uncertainty down to 0.5%
• Repeatability better than 0.05%
• Unique torsion oscillator
• Typical measuring ranges from 2 to 200 kg/min
• Minimal ows as low as 1 kg/min
• Optimized solutions for batching operation
• Customization possible
• Hazardous Area Approvals (ATEX, CSA, ...)
Medium Sized Coriolis
Mass Flowmeter
Advantages
• Torsion oscillator design assures most stable and
basically drift free measurement and increased
signal to noise ratio
• Not sensitive to changes in pressure
• Longest life time and increased safety (low stress
in welds and increased wall thickness against
abrasion)
• No moving parts, practically no maintenance
• Removable connection manifold available
GE
Measurement & Control
g

Process Connection Face to face length (L) Order Code
mm in
Standard Flange DIN DN25/PN40 400 15.75 D1
Flange DIN DN25/PN100 400 15.75 D2
Flange ANSI 1" 150# RF/SF 400 15.75 A1
Flange ANSI 1" 300# RF/SF 400 15.75 A2
Flange ANSI 1'' 600# RF/SF 400 15.75 A3
Flange ANSI 1" 1500# RTJ 450 17.72 R3
Optional Flange DIN DN25/PN160 400 15.75 D4
Flange ANSI 1" 1500# RF/SF 450 17.72 A6
Flange JIS RF 10k 25A (1") 400 15.75 J1
Flange JIS RF 20k 25A (1") 400 15.75 J2
General Dimensions RHM 15
PM0/SM0/PH0 (parallel/serial, manifold construction)
Type removable manifold with PTFE seals and thread connection
Type removable manifold with PTFE seals and ange connection
(only with PM0, SM0 manifold)
A1 = 285 mm (11.22 in) B1 = 50 mm (1.97 in) Terminal box (without cable gland) 125 x 80 x 58 mm (4.92 x 3.15 x 2.28 in)
A2 = 300 mm (11.81 in) B2 = 70 mm (2.76 in) W = 0 mm for Temperature Range T1 and TA
H1 = 454 mm (17.87 in) W = 150 mm (5.91 in) for Temperature Range T2
H2 = 481 mm (18.94 in)
For weights and packaging dimensions please see last page of this section.
Process Connection Face to face length (L) Order Code
mm in
Standard Female Thread G 3/4" 120 4.72 G1
Female Thread 3/4" NPT 120 4.72 N1
2

General Dimensions RHM 15
PF0 (parallel, sealless construction with ange connection)
Process Connection Face to face length (L) Order
Code
mm in
Standard Flange DIN DN40/PN40 400 15.75 C1
Flange DIN DN40/PN100 400 15.75 C2
Flange ANSI 1 1/2" 150# RF/SF 400 15.75 F1
Flange ANSI 1 1/2" 300# RF/SF 400 15.75 F2
Flange ANSI 1 1/2'' 600# RF/SF 400 15.75 F3
Flange ANSI 1 1/2" 1500# RF/SF 400 15.75 F5
Flange ANSI 1 1/2" 1500# RTJ 400 15.75 R4
Flange ANSI 1 1/2" 2500# RF/SF 450 17.72 F4
Flange ANSI 1 1/2" 2500# RTJ 450 17.72 R5
Optional Flange DIN DN40/PN160 400 15.75 C4
Flange ANSI 2" 1500# RTJ 500 19.69 R1
Grayloc Hub 1 1/2" GR11 400 15.75 H6
Grayloc Hub 2" GR11 400 15.75 H8
Grayloc Hub 2" GR14 400 15.75 H3
Flange JIS RF 10k 40A (1 1/2") 400 15.75 J1
Flange JIS RF 20k 40A (1 1/2") 400 15.75 J2
Type parallel, welded measuring loops without seals and ange connection
PFT (parallel sealless construction with thread connection)
Process Connection Face to face length (L) Order Code
mm in
Standard Female Thread G 3/4" 400 15.75 G1
Female Thread 3/4" NPT 400 15.75 N1
Swagelok ¾" Tube inlet (SS-
1210-1-12W)
470 18.50 W1
Type parallel, welded measuring loops without seals and thread connection
A1 = 285 mm (11.22 in) B1 = 50 mm (1.97 in) Terminal box (without cable gland) 125 x 80 x 58 mm (4.92 x 3.15 x 2.28 in)
A2 = 300 mm (11.81 in) B2 = 70 mm (2.76 in) W = 0 mm for Temperature Range T1 and TA
H1 = 454 mm (17.87 in) W = 150 mm (5.91 in) for Temperature Range T2, T3 and T4
H2 = 540 mm (21.26 in)
For weights and packaging dimensions please see last page of this section.
3

General Dimensions RHM 15
SF0 (serial, sealless construction without dead spaces)
Process Connection Face to face length (L) Order Code
mm in
Standard Flange DIN DN40/PN40 400 15.75 C1
Flange ANSI 1 1/2" 150#
RF/SF
400 15.75 F1
Flange ANSI 1 1/2" 300#
RF/SF
400 15.75 F2
Type single path, welded measuring loops without seals and sanitary connection
Type single path, welded measuring loops without seals and ange connection
A1 = 285 mm (11.22 in) B1 = 50 mm (1.97 in) Terminal box (without cable gland) 125 x 80 x 58 mm (4.92 x 3.15 x 2.28 in)
A2 = 300 mm (11.81 in) B2 = 70 mm (2.76 in) W = 0 mm for Temperature Range T1 and TA
H1 = 454 mm (17.87 in) V = 26 mm (1.02 in) W = 150 mm (5.91 in) for Temperature Range T2, T3 and T4
H2 = 540 mm (21.26 in)
(*) SF0 construction contains brazed joints (brazing material B-Ni82CrSiBFe-970/1000) which are not as corrosion resistant as the piping material 1.4571 (316Ti). Fully
welded joints for corrosive liquids and higher pressure ratings can be provided – please consult your local agent.
Weight in standard manifold construction with female threads: approx. 14 kg (31 lb)
Weight in standard sealless construction and 150# anges: approx. 16 kg (35 lb)
Shipping on pallet approx. 70 x 40 x 55 cm (27.6 x 15.7 x 21.7 in), gross weight with sealless construction, 150# standard anges and RHE 08 approx. 27 kg (60 lb)
Finish type of our ANSI anges corresponds to SF (AARH 125 up to 250 μin, Ra 3.2 up to 6.3 μm)
For customization with regard to face to face length and special ttings, please consult your local agent
Please note that larger diameter process connections are always possible
Process Connection Face to face length (L) Order Code
mm in
Standard Sanitary 1" Triclamp,
DIN 32676
350 13.78 S0
Sanitary NW20, DIN 11851 350 13.78 S2
4

Pressure Rating RHM 15
The maximum pressure (pmax) of a sensor is determined by its weakest part. The weakest part can be the measuring
loops (pmax indicated below) or the construction type (pmax indicated in the Basic Order Code section, last page) or the
selected anges / ttings (for pmax please see respective standard).
pmax of P1 measuring loops, standard
M1 standard material - 1.4571 (316Ti)
OD x WT 15 x 1 mm (0.59 x 0.039 in)
bar °C psi °F
165 50 2393 122
150 120 2176 248
127 210 1842 410
107 350 1552 662
pmax of P2 measuring loops
M1 standard material - 1.4571 (316Ti)
OD x WT 15 x 2 mm (0.59 x 0.079 in)
bar °C psi °F
352 50 5105 122
300 120 4351 248
250 210 3626 410
210 350 3046 662
pmax of P3 measuring loops
M1 standard material - 1.4571 (316Ti)
OD x WT 15 x 3 mm (0.59 x 0.118 in)
bar °C psi °F
540 50 7832 122
450 120 6527 248
350 210 5076 410
300 350 4351 662
pmax of P1 measuring loops
M3 optional material - 2.4602 (Alloy C22)
OD x WT 15 x 1 mm (0.59 x 0.039 in)
bar °C psi °F
228 50 3307 122
201 120 2915 248
172 210 2495 410
143 350 2074 662
pmax of P2 measuring loops
M3 optional material - 2.4602 (Alloy C22)
OD x WT 15 x 2.2 mm (0.59 x 0.087 in)
bar °C psi °F
540 50 7832 122
477 120 6918 248
407 210 5903 410
339 350 4917 662
5

Performance RHM 15
Standard Models
Flow Rate Uncertainty
kg/min lb/min in % of reading
200 441 0.20
100 220 0.20
50 110 0.20
10 22 0.20
48.8 0.50
Goldline Models (**) - selected sensors
Flow Rate Uncertainty
kg/min lb/min in % of reading
150 331 0.10
75 165 0.10
50 110 0.10
15 33.1 0.10
7.5 16.5 0.12
Low Flow Models (**) - selected sensors
Flow Rate Uncertainty
kg/min lb/min in % of reading
80 176 0.20
50 110 0.20
15 33 0.20
48.8 0.20
2 4.4 0.60
Repeatability
Better ± 0.1% of rate,
Goldline 0.05%
Density
Down to 0.5% uncertainty
Temperature
Better ± 1°C
(*) Nominal ow Qnom refers to roughly 8 - 10
m/s (26 - 33 ft/s) velocity in measuring loops
for best performance.
(**) Selected sensors are only available in
combination with temperature options T1, TA,
standard material and pressure range.
• Serial/single path versions oer the same accuracy at
half the ow (Qmax serial version = 100 kg/min).
• No relevant pressure eect due to torsional oscillation
and semi-circle (non-deforming) measurement
section.
• Uncertainty of reading (incl. zero drift) indications refer
to reference conditions H2O, 18-24°C (66 - 76°F), 1 - 3
bar (15 – 45 psi) and installation according to eld
manual.
• Pressure drop indications refer to H2O, with parallel
measuring loops type P1 and standard manifold block
connections.
• For calibration to customer range and / or with
improved uncertainty, please consult factory.
Uncertainty % DP (bar)
Uncertainty % DP (bar)
Uncertainty % DP (bar)
Flow Rate kg/min
Flow Rate kg/min
Flow Rate kg/min
Max Flow Rate Qmax = 200 kg/min (441 lb/min), Qnom (*) = 150 kg/min (331 lb/min)
6

RHM 15 Specications
Temperature Range
• NT Models from -20 to +120°C (-4 to +248°F)
• ET Models from -45 to +120°C (-49 to +248°F)
• ET2 Models from -45 to +210°C (-49 to +410°F)
• ET1 Models from -196 to +50°C (-320 to +122°F)
• HT Models from 0 to 350°C (+32 to +662°F)
(Heating for housing optional, please consult your local
agent)
Electrical Connection
• Junction box Aluminium coated (standard). Junction
box in SS 316Ti optional
• Cable entry M25 x 1.5. Optional cable entries M20 x 1.5,
1/2” NPT or 3/4” NPT
• Max cable length between RHM and RHE is 100m (330
ft). 200m (660 ft) only with factory approval
Material of Wetted Parts
• 1.4571 / SS 316 Ti / UNS S31635 (standard)
• 2.4602 / Alloy C22 / UNS N06022
• Tantalum
• Others on request
Sensor Enclosure/Housing
• Stainless Steel 1.4301 / SS 304, optional in 1.4571 / SS
316Ti. Others on request
• Protection Class IP 65. Optional IP 66 / NEMA 4x
Approvals
• ATEX Ex II 1 G, EEx ia IIC T6-T1
• CSA USA-Canada, Class I, Div. 1, Groups A, B, C, D
• PED according to directive 97/23/EC: Art.3 (3) Sound
Engineering Practice (SEP), Module A1 or Module B + C1
– depending on construction type and measured uid
• Others on request
7

Sensor Size
Temperature Rating
T1 NT from -20°C to +120°C (standard)
TA ET from -45°C to +120°C
T2 ET2 Extended Temperature Range from -45°C to +210°C
T3 ET1 Extended Temperature Range from -196°C to +50°C
T4 HT High Temperature Range from 0°C to +350°C
Pressure Range of Measuring Loops @ 120°C and M1 Material
P1 pmax = 150 bar, max. CL 600 / PN40 (standard)
P2 pmax = 300 bar
P3 pmax = 450 bar-
Construction Type (pmax indications @ 120°C)
PM0 Parallel Measuring Loops with removable Manifold and PTFE Seals,
pmax = 230 bar with thread connection, 214 bar with ange connection
SM0 Serial Measuring Loops with removable Manifold and PTFE Seals,
pmax = 230 bar with thread connection, 214 bar with ange connection
PH0 Parallel Measuring Loops with High Pressure Manifold and PTFE Seals, pmax = 420 bar
PF0 Parallel Measuring Loops Seal Less Version
SF0 Serial Measuring Loops Seal Less Version Sanitary, pmax = 42.9 bar
upon request, a fully welded version is available, pmax = 325 bar
PFT Parallel Measuring Loops Seal Less Version for Thread Connection, pmax = 250 bar
Material of Wetted Parts
M1 Measuring Loops and Manifold/Connection 1.4571 (316Ti) (standard)
M3 Measuring Loops and Connection Part 2.4602 (Alloy C22), Seal Less Construction only
M4 Measuring Loops and Connection Part Tantalum, PF0 Construction Type only
Process Connection
D1 Flange DIN DN25/PN40 Form C (EN 1092-1 Form B1)
D2 Flange DIN DN25/PN100 Form E (EN 1092-1 Form B2)
C1 Flange DIN DN40/PN40 Form C (EN 1092-1 Form B1)
C2 Flange DIN DN40/PN100 Form E (EN 1092-1 Form B2)
A1 Flange ANSI 1” 150# RF/SF
A2 Flange ANSI 1” 300# RF/SF
A3 Flange ANSI 1” 600# RF/SF
R3 Flange ANSI 1” 1500# RTJ
F1 Flange ANSI 1 ½” 150# RF/SF
F2 Flange ANSI 1 ½” 300# RF/SF
F3 Flange ANSI 1 ½” 600# RF/SF
F5 Flange ANSI 1 ½” 1500# RF/SF
R4 Flange ANSI 1 ½” 1500# RTJ
F4 Flange ANSI 1 ½” 2500# RF/SF
R5 Flange ANSI 1 ½” 2500# RTJ
G1 Female Thread G 3/4”
N1 Female Thread 3/4” NPT
W1 Swagelok 3/4” Tube inlet (SS-1210-1-12W), standard material only
S0 Sanitary 1” Triclamp, DIN 32676, pmax = 17.2 bar @ 120°C
S2 Sanitary NW20, DIN 11851, pmax = 40 bar @ 120°C
Others on request
RHM15 - - - -
Basic Order Code RHM 15
920-498A
© 2013 General Electric Company. All Rights Reserved. Specications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product
names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not aliated with GE.
gwww.ge-mcs.com
Other GE Measuring Instrument manuals

GE
GE PM880 User manual

GE
GE DigitalFlow GC868 Owner's manual

GE
GE Sievers 500 RL User manual

GE
GE Corometrics 170 Series User manual

GE
GE TransPort PT900 User manual

GE
GE RHM 12 User manual

GE
GE Baker Hughes PanaFlow LC XMT1000 User manual

GE
GE PACE 1000 Instruction Manual

GE
GE DigitalFlow GS868 Owner's manual

GE
GE XDP-H2 User manual
Popular Measuring Instrument manuals by other brands

SOMFY
SOMFY 1875110 manual

Badger Meter
Badger Meter Impeller 228PV150U Series user manual

MicroLux
MicroLux Laserkinfe 2525 Owner's manual and instructions

Agilent Technologies
Agilent Technologies ESA-E E4407B Installation note

Thermo Electron
Thermo Electron 48C instruction manual

Leupold
Leupold RX-600 Series Operation manual