Installation Instructions
iMPORTANT SAFETY iNSTRUCTiONS
This product requires a three-i)rong grounded outlet.
Tile installer must perform a ground contimfitv check
oil the power outlet box before beginning tile
installation to insure that the outlet box is properly
grounded. If not properly gromlded, or if tile outlet
box does not meet electrical requirements noted
(under EI,ECTRICAI, REQLIIREMENTS), a qualified
electrician should be employed to correct any
deficiencies.
w
lll//ll// 1
p
CAUTION:
For personal safety, remove
house fuse or open circuit
breaker before beginning
installation to avoid severe
or fatal shock injury.
CAUTION: ForpersonalsafeS,themounting
surface must be capable of supporting the cabinet load,
in addition to the added weight of this 63-85 pound
product, plus additional oven loads of up to 50 pounds
or a total weight of 113-135 pounds.
CAUTION: For personal safety, this product
ca_mot be installed in cabinet arrangements such as an
island or a peninsula. It must be mounted to BOTH
a top cabinet AND a waJL
NOTE: For easier installation and personal safety, it is
recommended that two people install tlfis product.
IMPORTANT--PLEASE READ CAREFULLY. FOR
PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED TO AVOID SEVERE OR
FATAL SHOCK.
Insure proper
ground exists
before use
Tile power cord of this
appliaJace is equipped with
a three-prong (grounding)
plug which mates with
a standard three-prong
(grounding) wall receptacle
to m_ize the possibility
of electric shock hazard
from tlfis appliance.
You should have the wall receptacle and circuit checked
by aqualified electrician to make sure the receptacle is
properly grounded.
Where a standard two-prong wall receptacle is
encountered, it is very important to have it replaced
with aproperly grounded three-prong wa3l receptacle,
installed by a qualified electriciaaa.
DO NOT, UNDFa;t ANY CIRCUMSTANCES, CUT,
DI?_'ORM OR REMOVE ANY OF THE PRONGS
FROM THE POWER CORD. DO NOT USE WITH
AN EXTENSION CORD.
ELECTRICAL
REQUIREMENTS
Produrt rating is 120 volts AC, 60 He_z, 14 amps and
1.60 kilowatts. This product must be connected to a
supply drcuit of tile proper voltage and _'equencv.
Wire size must confimn to the requirements of the
National Electrical (?,ode or the l)re\;filing local code
for this kilowatt rating. The power supply cord and
plug should be brought to a separate l 5 to 20 ampere
branch drcuit single grotmded outlet. The outlet box
should be located in the cabinet abo\v the oren. The
outlet box and supply drctfit should be installed by
a qualified electddan and confiwm to the National
Electrical Code or the pre\uiling local code.
3