Advance Planning
ADVANCE PLANNING
Ductwork Planning
,This hood is equipped for 8" round ductwork.
, Determine the exact locution of the vent hood.
, Plan the route for venting exhaust to the outdoors.
This hood is not designed for erecirculeting
venting operation.
, Use the shortest end straightest duct route
possible. For satisfactory performance, duct run
should not exceed 100 ft. equivalent length for any
duct configurations.
, Refer to "Duct Fittings" chert to compute the
maximum permissible length for duct runs to the
outdoors.
, Use rigid metal ductwork only.
,install e well or roof cup with damper at the
exterior opening. Order the cop end any transitions
needed in advance.
Wall and Ceiling Framing for Adequate Support
This vent hood is heavy and the cabinet structure
needs to support the weight of the loaded insert
sleeve. Adequate structural support must be
provided in all types of installations.
• Installation will be easier if the vent hood is
installed before the cooktop is installed.
Custom Cabinet Frame Planning
,The custom-built canopy should be sized to
accommodate the hood insert sleeve. See pages
5-9 for details.
Remote Mounting of the Control (Wired}
,The control can be remotely mounted on the well
or the countertop.
, It is recommended that you use oprofessional
installer for the countertop cutout.
, It is recommended that the cutout in ogranite
countertop or other herd surface be made before
the countertop is installed.
,The cutout needs to be made at least 6 inches
from the edges of the countertop.
, If mounting in the countertop above o drawer,
consideration must be given to the depth of the
control mounting assembly.
,A 30 ft. wire cord is provided. Careful consideration
must be given to the location of the remotely
mounted control.
, It is recommended that the 4-wire cord be routed
through 1" conduit between the insert sleeve end
the remote mounting location.
POWER SUPPLY
IMPORTANT -(Please read carefully)
,&WARNING:
FOR PERSONAL SAFETY,THIS APPLIANCE MUST BE
PROPERLYGROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use on extension cord or adopter plug with
this appliance. Follow National electrical codes or
prevailing local codes and ordinances.
Electrical Supply
This vent hood must be supplied with 120V, 60Hz,
end connected to on individual, properly grounded
brunch circuit, end protected by u15 or 20 amp
circuit breaker or time delay fuse.
, Wiring must be 2 wire with ground.
, For supply connection, use wires suitable for at
least 75°C (167°F).
, If the electrical supply does not meet the above
requirements, cell elicensed electrician before
proceeding.
, Route house wiring as close to the installation
locution us possible, in the ceiling or beck well.
, Connect the hood wiring to the house wiring in
accordance with local codes.
, House wiring must extend to 45" minimum from
bottom of cabinet in order to make connection to
hood wiring.
Grounding Instructions
The grounding conductor must be connected to o
grounded metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
A WARNING: Theimproper connection
of the equipment-grounding conductor can result
in e risk of electric shock. Check with e qualified
electrician or service representative if you ere in
doubt whether the appliance is properly grounded.