Technical Specs
Maximum Output Current ............................5 A
Panel Voc.............................................. 0 –27 V
Operating Consumption..... 150 µA (0.150 mA)
Night Consumption ............ 125 µA (0.125 mA)
Float Voltage ...........................................13.8 V
Absorption Voltage..................................14.2 V
Disconnect/Reconnect Voltage......11.4/12.5 V
(GV-5-Li: no absorption stage)
GV-5-Li-12.5V, Float Voltage, ...............12.5 V
Disconnect/Reconnect Voltage........9.3/10.5 V
GV-5-Li-14.2V, Float Voltage ................14.2 V
Disconnect/Reconnect Voltage......12.0/12.4 V
GV-5-Li-16.7V, Float Voltage ................16.7 V
Disconnect/Reconnect Voltage......12.4/14.0 V
Electrical Efficiency (typical)...........94% - 98%
Tracking Efficiency (typical)......................99%
Continuous LVD Output..............................5+A
Operational Temperatures.......... -40ºC –85ºC
Weight ............................................2.8 oz., 80 g
Size ............. 4.3 x 2.2 x 0.9", 11 x 5.6 x 2.5 cm
Note: The positive side of the battery is
connected to the positive side of the
solar panel.
Do not connect the solar panel
to your system ground!
The GV line of Solar Charge Controllers
with Maximum Power Point Tracking:
GV-4: Available for 12V Lithium or Lead-
Acid Batteries. Output current: up to 4A.
GV-5: Available for 12V Lithium or Lead-
Acid Batteries. Output current: up to 5A.
Low voltage disconnect for continuous
loads up to 5A.
GV-10: Available for 12V Lithium or
Lead-Acid Batteries. Output current: up
to 10.5A.
GV Boost Controllers for systems with
battery voltage higher than the panel
voltage. GV Boost Controllers are
available for systems with 12V, 24V, 36V,
and 48V battery voltages.
http://www.genasun.com
1035 Cambridge St. • Suite 16B
Cambridge, MA 02141 • USA
GV-5
Genasun Solar Charge Controller
with Maximum Power Point Tracking
User’s Manual &
Operating Instructions:
Genasun GV-5 and GV-5-Li