globalindustrial.com
Single Speed Exhaust Fan
Assembly
Instructions
Customer Service
US: 888-628-3466
Canada: 888-645-2986
Mexico: 01.800.681.6940
1
Models
Fan With Shutter
248448 - 10"
294495 - 12"
294496 - 18"
294497 - 24"
Fan
246506 - 10"
246507 - 12"
246508 - 18"
246509 - 24"
•TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
• This product contains chemicals which are known to the
state of California to cause birth defects or other
reproductive harm.
• This exhaust fan is not for use in explosive or combustible
atmospheres.
• Read and follow all instructions before operating fan.
• Do not use fan if any part is damaged or missing.
• Do not alter the fan’s assembly.
• All electrical connections should be made by a qualified
electrician. Installation work and electrical wiring must be
done by qualified person(s) following all local electrical and
safety codes in the United States and Canada, as well as
the National electrical Code (NEC) and the Occupational
Safety and Health Act (OSHA) in the United States, and the
Canadian Electric Code (CEC) in Canada.
• Use OSHA approved lock-out tag-out devices on power
supply to prevent shock and/or electrocution.
• When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
• To reduce the risk of fire or electrical shock, do not expose to
water or rain.
• To reduce the risk of fire or electrical shock, do not use this
fan with any solid state speed control device.
• To reduce the risk of fire or electrical shock, do not use an
extension cord, unit is intended to be permanently hard
wired to properly rated electrical service outlet (120V 60Hz).
• To reduce the risk of injury to persons, install fan at least 7
feet (2.1m) above the floor (8 feet in Canada).
• The fan frame and motor must be electrically grounded to a
suitable electrical ground, such as a grounded water pipe or
ground wire system.
• This has a single speed motor which is equipped with a
thermo – protector and will automatically de-energize the fan
if it overheats for any reason.
RULES FOR SAFE OPERATION:
1. Never insert fingers or any other objects through the grill
guard when fan is in operation.
2. Install in interior wall. Not for use in kitchens.
3. Disconnect the fan from its power source when removing
guards for cleaning.
4. Do not use the fan in windows. Rain and moisture may
create electrical hazard.
5. Do not place the fan near an open flame, cooking or heating
appliance, or hot surface.
6. This fan is for indoor dry applications.
7. This fan should not be operated outside.
8. For proper exhaust operation, a window, door, or louver
should be opened on the opposite side of the area to be
ventilated.
9. Periodically clean the propeller, guard, motor, and louver of
any accumulated dirt.
WARNING
READ & SAVE THESE INSTRUCTIONS
Exhaust Fan_Single Speed _248448_2944495-294497 8/15/14 8:18 AM Page 2
Assembly Instructions
Single Speed Exhaust Fan
2
SHUTTER INSTALLATION
INSTRUCTIONS
1. The unit has to be securely mounted in
a rigid framework. See chart below for
the recommended wall hole sizes.
Mounting hardware is not included.
Use appropriate hardware for wall
condition.
Model Size Recommended rough in hole size
248448 10" 10.5" square hole
294495 12" 12.5" square hole
294496 18" 19" square hole
294497 24" 25" square hole
Model Diameter A B C Max. D E
(Open Louver)
248448 10" 13" 10" 5" 21/2"6"
294495 12" 15" 12" 51/2"2
1/2"6"
294496 18" 21" 18" 51/2"2
1/2"7"
294497 24" 27" 24" 51/2"2
1/2"8"
2. Be sure when mounted that the louver
blades will open upward.
TOP
BOTTOM
A
BB
E D
C Max
(Open Louver)
31/2"
1/4" x 1/2" Slot
Exhaust Fan_Single Speed _248448_2944495-294497 8/15/14 8:18 AM Page 3
Assembly Instructions
Single Speed Exhaust Fan
3. Use appropriate screws for framework
and wall conditions.
To mount louver assembly, use the eight
pre-punched 1/4
"
x 1/2" slotted mounting
holes of the louver assembly to attach
the unit to the framework.
4. Seal the joint between the wall and the
louver with silicon or any other sealer.
5. Insert the square plastic plugs into the
square holes on corner gussets located
on the back side of the shutter.
6. Remove screws, washers and nuts from
the protective screen of the fan.
3
Exhaust Fan_Single Speed _248448_2944495-294497 8/15/14 8:18 AM Page 4
Assembly Instructions
Single Speed Exhaust Fan
4
7. Use bolts H1 and washers H2 and
vibration pad H3 to assemble motor/fan-
guard to inner fan guard to louver-
assembly.
FAN INSTALLATION INSTRUCTIONS
8. Connect power to the motor, using the appropriate wiring
method. Place all connections inside junction box.
Model Rating (120V 60Hz)
246506 45W, 0.38A
246507 65W, 0.55A
246508 160W, 1.25A
246509 245W, 2.2A
Bolt Flat Washer Vibration Pad
H1 H2 H3
4 Pieces 4 Pieces 4 Pieces
H3
H2
H1
Black
L
N
GMotor
Wiring Diagram
White
Blue
C
Yellow/Green
Junction Box
WARNING
This product contains chemicals which are known
to the state of California to cause birth defects
or other reproductive harm.
Exhaust Fan_Single Speed _248448_2944495-294497 8/15/14 8:18 AM Page 1

This manual suits for next models

7

Other Global Fan manuals

Global 292650 User manual

Global

Global 292650 User manual

Global 292649 User manual

Global

Global 292649 User manual

Global 293047 User manual

Global

Global 293047 User manual

Global MH-MF40A User manual

Global

Global MH-MF40A User manual

Global 293042 User manual

Global

Global 293042 User manual

Global 246340 User manual

Global

Global 246340 User manual

Global 246340 User manual

Global

Global 246340 User manual

Global FE-60DFOL User manual

Global

Global FE-60DFOL User manual

Global 294498 User manual

Global

Global 294498 User manual

Global 292650 User manual

Global

Global 292650 User manual

Global 292677 User manual

Global

Global 292677 User manual

Global 292607 User manual

Global

Global 292607 User manual

Global FE-105D5fOL(H) User manual

Global

Global FE-105D5fOL(H) User manual

Global 585279 User manual

Global

Global 585279 User manual

Popular Fan manuals by other brands

Progress Lighting AirPro P250004 installation manual

Progress Lighting

Progress Lighting AirPro P250004 installation manual

Vents-us VKP 100 Installation guides

Vents-us

Vents-us VKP 100 Installation guides

ZIEHL-ABEGG FA Series Assembly instructions

ZIEHL-ABEGG

ZIEHL-ABEGG FA Series Assembly instructions

Excel 52-AGT manual

Excel

Excel 52-AGT manual

Salda RIS 2500PE 4.5 EKO 3.0 Technical manual

Salda

Salda RIS 2500PE 4.5 EKO 3.0 Technical manual

GLUCKSTEIN ELEMENTS DENVER 38711-HBC DENVER 38711-HBCW Use and care guide

GLUCKSTEIN ELEMENTS

GLUCKSTEIN ELEMENTS DENVER 38711-HBC DENVER 38711-HBCW Use and care guide

Brink Renovent Sky 150 installation instructions

Brink

Brink Renovent Sky 150 installation instructions

NSA TFDC-46RC instruction manual

NSA

NSA TFDC-46RC instruction manual

DeLonghi DETF121 user guide

DeLonghi

DeLonghi DETF121 user guide

Intertek Vent-Axia Svara instructions

Intertek

Intertek Vent-Axia Svara instructions

Salda RIS 400HE Technical data

Salda

Salda RIS 400HE Technical data

Stark 92010 Owner's manual and safety instructions

Stark

Stark 92010 Owner's manual and safety instructions

Tekno Point RPS Series Assembly instruction

Tekno Point

Tekno Point RPS Series Assembly instruction

RL R62743131 manual

RL

RL R62743131 manual

Pelonis FZ10-9HB owner's manual

Pelonis

Pelonis FZ10-9HB owner's manual

Sea gull lighting 1525 Series owner's manual

Sea gull lighting

Sea gull lighting 1525 Series owner's manual

EUROM Vento 3DS instruction manual

EUROM

EUROM Vento 3DS instruction manual

Geovent PM-180-1 instruction manual

Geovent

Geovent PM-180-1 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.