Global BEAT-MV User manual

USER MANUAL
ELECTROFUSION CONTROL BOX
MODELS BEAT-MV/BEAT-2
Edition: January 2016
Revision No. 1
Publication: MU-78-14E

DATOS DEL FABRICANTE
MANUFACTURER DATA
ACUSTER GLOBAL, S.L.
Ctra. Montcada, 608
08223 Terrassa (Barcelona) - SPAIN
Tel. (+34) 93 736 18 80
e-mail: [email protected]
DATOS DEL DISTRIBUIDOR Y SAT
DISTRIBUTOR AND SERVICE DATA
STP Acuster Internacional
Crta. Montcada, 608
08223 Terrassa (Barcelona) - SPAIN
hello @stpacuster.com
+34937361880
STP Acuster North Europe
Ind. terrein de Wildeman, hof 4
Bossekamp 12
5301 LZ Zaltbommel - The Netherlands
+31418840003
STP Acuster Central Europe
2, Kvetna 685, Areal Salvia
736 61 Napajedla - Czech Republic
+420577913065
STP Acuster Baltics
Bullu str. 45
Riga, LV1067 - Latvia
+37167815281
STP Acuster South Africa
54 Richard Road, Industria North
PO BOX 2203 Wilro Park
1731 Roodepoort - South Africa
+27315397451
Agru Acuster Chile
Lo Echevers 891,
Bodegas 11 y 12, Quilicura,
Santiago - Chile
+56229493910
Agru Acuster Brasil
Rua Saburo Sumiya, 211
Aldeia, Barueri, SP
CEP: 06440-110 – Brasil
+55114138088
NOTE !
At the time of the publication of this User Manual, the software version
is V. 1.35.2
The modifications carried out against the previous revision of this
publication are indicated with 2on the right margin.

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
Revision: No. 1 GENERAL INDEX - 3
CONTENTS:
Page:
CHAPTER 1: INTRODUCTION............................................................................ 5
1.1 General.................................................................... 5
1.2 Design Specifications................................................. 6
1.3 General Information.................................................. 6
1.4 Unit Identification...................................................... 7
1.4.1 Serial number stamping............................................. 7
1.4.2 CE making................................................................ 7
1.5 Measures of protection against accidents...................... 8
1.5.1 Safety alert symbols........................................ 8
1.5.2 Safety measures and dangers........................... 8
1.6 Declaration “CE” of conformity.................................... 10
1.7 Guarantee................................................................ 11
CHAPTER 2: DESCRIPTION OF THE ELECTROFUSION UNIT................................... 12
2.1 General.................................................................... 12
2.2 Front....................................................................... 13
2.3 Right side................................................................ 13
2.4 Left side................................................................... 14
2.5 Top side................................................................... 14
CHAPTER 3: MODE OF USE............................................................................... 15
3.1 Electrofusion procedure.............................................. 15
3.1.1 Scraping pipe surfaces............................................... 15
3.1.2 Fitting installation...................................................... 15
3.1.3 Unit connection......................................................... 16
3.1.4 Using the Barcode reader........................................... 18
3.1.5 Fitting connection...................................................... 19
3.1.6 Entering electrofusion data in the unit.......................... 19
3.1.7 Electrofusion process................................................. 21
3.1.8 Cooling time............................................................. 22
3.2 Access to other menus............................................... 23
3.2.1 Available options....................................................... 23
3.2.2 INFO option.............................................................. 23
3.2.3 SETUP option............................................................ 24
3.2.4 LAST REVISION option............................................... 24
3.2.5 SERVICE option......................................................... 24

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
- GENERAL INDEX Revision: No. 14
Page:
CHAPTER 4: TROUBLESHOOTING...................................................................... 25
4.1 General.................................................................... 25
4.2 Display error messages.............................................. 25
4.2.1 Input voltage/frequency............................................. 25
4.2.2 Fitting resistance outside margin................................. 26
4.2.3 Interruption by operator............................................. 26
4.2.4 Output current.......................................................... 26
4.2.5 Electrofusion output voltage....................................... 27
4.2.6 Protection against internal temperature........................ 27
CHAPTER 5: MAINTENANCE.............................................................................. 28
5.1 General.................................................................... 28
5.1.1 Introduction.............................................................. 28
5.1.2 Storage.................................................................... 28
5.1.3 Cleaning................................................................... 28
5.1.4 Checks..................................................................... 28
5.2 Control unit.............................................................. 29
5.2.1 Electronic control unit................................................ 29
5.2.2 Updating the programme software............................... 29
CHAPTER 6: TECHNICAL CHARACTERISTICS....................................................... 30
6.1 Electrofusion control unit............................................ 30
6.1.1 General specifications................................................ 30
6.1.2 Generator specifications............................................. 31
6.2 Size and weight......................................................... 31
6.2.1 Weights and dimensions............................................. 31
6.2.2 Accessories............................................................... 31

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
Revision: No. 1 INTRODUCTION - 5
CHAPTER 1: INTRODUCTION
1.1 GENERAL
The ele trofusion units BEAT-MV and BEAT-2 are designed to arry out polyethylene
(PE) or polypropylene (PP) pipe/fittings joints through ele trofusion fittings with a range
of 8 V to 48 V ele trofusion voltage.
This User Manual orresponds to the following models:
BEAT-MV Ele trofusion unit whi h the ele trofusion parameters are entered
manually. No tra eability.
BEAT-2 Ele trofusion unit that the ele trofusion parameters an be entered
manually or by bar ode system. No tra eability.
The BEAT-MV ele trofusion unit re eives the relevant data of the fitting via operator’s
manual introdu tion: VOLTAGE and TIME from the fitting manufa turer. Take into a ount
that some fitting manufa turers provide different fusion times a ording to ambient
temperature. Refer to the fitting manufa turer’s instru tions.
The BEAT-2, in addition of the data manual input is also able to enter the ele trofusion
parameters by means of a bar ode automati re ognition system.
These models an be optionally supplied as AR Series (High Performan e) with the same
original te hni al spe ifi ations, ex ept for having a higher duty y le. The AR series is
espe ially indi ated for ongoing ele trofusion of large size fittings and for very hot
limates.
The te hni al data ontained in this Manual are purely informative and may be hanged
at anytime. ACUSTER GLOBAL, S.L. de lines all responsibility for laims arising from
misuse of the data ontained herewith and/or errors or omissions dete ted after
publi ation.
This Manual must be onsidered as part of the unit.

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
- INTRODUCTION Revision: No. 1 6
1.2 DESIGN SPECIFICATIONS
The ele trofusion units BEAT-MV and BEAT-2 are designed a ording to the following
spe ifi ations:
CISO 12176-2 Equipment for fusion jointing polyethylene systems.
Part 2: Ele trofusion.
CISO/TR 13950 Plasti pipes and fittings: automati re ognition of ele trofusion
systems.
The BEAT-2 a epts all the identifi ations whi h orrespond to the above listed
Spe ifi ations. All the fittings an be fused by ele trofusion if the manufa turer en loses
the programmed bar ode system in a ordan e with ISO/TR 13950.
1.3 GENERAL INFORMATION
The development, do umentation, produ tion, tests and shipping of the produ ts herewith
des ribed have been made:
MComplying with the respe tive safety rules, and
MIn a ordan e with the requirements of quality guarantee.
WARNING !
The ele trofusion ontrol box an only be opened by the A uster’s After-
sales Servi e. In the ase of the ba k over opening or oming apart,
parts of ele tri al omponents whi h are not overed may be left
exposed.
Only qualified personnel are authorised to intervene both for fusion and
repairs. These qualified personnel must be familiar with all the safety
measures, potential dangers and maintenan e rules des ribed in this
Manual.
The safe use of the produ ts des ribed requires an appropriate means of
transport, storage, installation and use, a areful handling and the
preestablished periodi al maintenan e follow-up.

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
Revision: No. 1 INTRODUCTION - 7
1.4 UNIT IDENTIFICATION
1.4.1 Serial Number S amping:
The ele trofusion units BEAT-MV and BEAT-2 are identified by means of their own
identifi ation plate.
QUALITY CONTROL ACUSTER GLOBAL
CONTROL DE CALIDAD
MACHINE No. EQUIPO Nº
MAINTENANCE
REVISIONS
" REVISIONES "
MANUFACTURER'S
ADDRESS
Juan de la Cierva, 1 - Políg. Ind. del sud-oest
Telf. +34 93 4703070 - Sant Just Desvern (Bar elona)
Figure
The quality ontrol identifi ation plate in ludes the fusion ontrol box serial number. The
plate in ludes room for future maintenan e date stamping.
1.4.2 "CE" marking:
The ele trofusion unit is supplied with the appropriate plate with the "CE" mark, as the
European Community norm indi ates on the new Ma hine Se urity Regulation (Board
98/37/CE, dated 22nd June 1998).
ACUSTER GLOBAL
C E
" MODELO: "
Nº SERIE
Juan de la Cierva, 1 - Políg. Ind. del sud-oest
Telf.+34 93 4703070 - Sant Just Desvern (Bar elona)- SPAIN
Figure 2

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
- INTRODUCTION Revision: No. 1 8
1.5 MEASURES OF PROTECTION AGAINST ACCIDENTS
1.5.1 Safe y aler symbols:
This User Manual employs the following safety alert symbols:
Indi ates information, onsidered important, but not hazard-
related.
When appears this hazard alert sign in this manual, arefully read
what is says.
Indi ates a hazardous situation that, if not avoided, will result in
death or serious injury.
Indi ates a hazardous situation that, if not avoided, ould result in
death or serious injury.
Indi ates a hazardous situation that, if not avoided, ould result in
minor or moderate injury.
1.5.2 Safe y measures and dangers:
Please go by the following safety measures:
MKeep the fusion ontrol box out of the rea h of non authorised personnel, non qualified
personnel and hildren. Prote t the ontrol unit from water, rain, snow, et .
MWhen transporting the unit, and during loading and unloading operations, the
appropriate pre autionary measures must be taken to ensure that all unit omponents
are ompletely se ured in the vehi le, and that they are free from impa t during
transportation.
MProte t the ele trofusion ables and the able that goes to the power supply of utting
obje ts.
MAll damaged ables must be repla ed immediately by the After-Sales Servi e of
STPA uster.
MAlways plug the ontrol box to a power supply provided with differential and ground
onne tion.
MDo not expose the fusion ontrol box to heavy weights. All slight damage aused to
the external frame or to other elements will have to be repla ed immediately by the
After-Sales Servi e of STPA uster.

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
Revision: No. 1 INTRODUCTION - 9
MThe fusion ontrol boxes whi h are not being used must be kept out of the rea h of
the non authorised personnel. They will have to be kept in rooms of low humidity
degrees and of restri ted a ess.
MAlways use adequate working lothes.
For outside work, it is re ommended to use rubber gloves and boots with insulating
soles (in wet areas, this advi e is essential), and other appli able personal prote tive
equipment su h as hard hat, safety glasses, et .
For indoor fusion jointing work, adequate ventilation of the premises must be
provided.
MBefore using the fusion ontrol box, its external ondition will have to be he ked, as
well as its working ondition. All omponents must be orre tly assembled in order to
guarantee the orre t fun tioning of the unit.
MThe damaged omponents must be repaired or repla ed by the After-Sales Servi e of
STPA uster.
MThe fusion ontrol box an only be opened by the After-Sales Servi e of STPA uster.
MShould the fusion ontrol box not work properly, it will have to be sent immediately
to the After-Sales Servi e of STPA uster.

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
- INTRODUCTION Revision: No. 1 10
1.6 DECLARATION "CE" OF CONFORMITY
ACUSTER GLOBAL, S.L.
Ctra. Mont ada, 608
08223 Terrassa (Bar elona)
SPAIN
de lare under our sole responsibility that the ele trofusion units BEAT-MV
and BEAT-2, to whi h this de laration relates is in onformity with the
following Dire tives and also the following relating standards:
Direc ive Rela ed Specifica ion Model
2006/95/CEE
Low Voltage
EN 60204-1
EN 60335-1; EN 60519-1
BEAT-MV
&
BEAT-2
2004/108/CEE
Electromagnetic compatibility
EN 61000-6-2
EN 61000-6-3
2002/95/CEE
ROHS
EN 62321-1
2002/96/CEE
WEEE
ISO 12176-2
ISO/TR 13950 BEAT-2
Sant Just Desvern, 20th September 2012
Jaume Puig
General Manager

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
Revision: No. 1 INTRODUCTION - 11
1.7 GUARANTEE
Guaran ee Declara ion:
All the ele trofusion units BEAT-MV and BEAT-2 are manufa tured from high
quality material and have been subje ted to rigorous tests for resistan e and
working order as well as passing all the quality ontrol tests required by the
appli able normative (see "CE" De laration of onformity).
Regardless of whether an in ident might o ur during the period of guarantee,
we re ommend areful reading of the following general guarantee onditions.
General condi ions of Guaran ee:
1. ACUSTER GLOBAL, S.L. guarantees that this produ t has no manufa turing
defe t at the time of its pur hase and extends this guarantee for the period
of TWO years.
2. If the produ t proves defe tive during this period, due to the materials or
its assembly, it will be repaired free of harge, in luding the ost of
materials and labour at STPA uster’s Te hni al Servi e.
3. The Guarantee is not valid in the following ases:
When the fault in the produ t is a result of:
!Abuse or in orre t use of the unit
!Not following the instru tions spe ified in this User Manual for
onne ting to a group generator.
!Repairs arried out without authority from STPA uster (the taking
apart or breaking of the unit's seal immediately renders the guarantee
invalid).
!A idents, natural disasters (in luding lightning, water a tion et ) as
well as any ause beyond STPA uster’s ontrol.
4. In all laims against this guarantee, information relating to the model, date
of pur hase, Serial number and any other additional information must at all
times be stated.

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
- MACHINE’S DESCRIPTION Revision: No. 112
CHAPTER 2: UNIT’S DESCRIPTION
2.1 GENERAL
The electrofusion units BEAT-MV and BEAT-2 are made up of a metal casing, a master
switch, the mains and electrofusion cables. Additionally the BEAT-2 is fitted with a d-sub
connector for the connection of scanner and PC.
The front part is formed by a membrane which incorporates tactile push-buttons to enter
the data and a back-lit LCD display.
Inside, the unit is formed by a processor board (CPU), transformer, in addition to all of
the electronics necessary for the electrofusion process, current and voltage controls.
Figure 3a: BEAT-MV general view Figure 3b: BEAT-2 general view

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
Revision: No. 1 MACHINE’S DESCRIPTION - 13
2.2 FRONT
The front part of BEAT-MV and BEAT-2 electrofusion unit is formed by a silkscreened
plastic membrane which incorporates membrane type tactile push-buttons. The display
is located on the upper left side.
Where:
1Membrane with push-buttons
2Display
3Master switch
4Connector D-sub 9 pins (BEAT-2)
5Adhesive of model: MV or 2
Figure 4
2.3 RIGHT SIDE
On the right side of the BEAT-MV and BEAT-2 electrofusion unit (looking at it from the
front), the following elements are located:
1Technical specifications sticker
2“CE” plate
3Service revisions plate
Figure 5

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
- MACHINE’S DESCRIPTION Revision: No. 114
2.4 LEFT SIDE
On the left side of the BEAT-MV and BEAT-2 electrofusion unit (looking at it from the
front), the following elements are located:
1Document holder bag (BEAT-2)
2RT sensor
3Buzzer
Figure 6
2.5 REAR
At the top of the BEAT-MV and BEAT-2 are located the following components.
1Transport handle
2Power cable
3Electrofusion cables
Figure 7

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
Revision: No. 1 MODE OF USE - 15
CHAPTER 3: MODE OF USE
3.1 FUSION PROCEDURE FOR ELECTROFUSION FITTINGS
3.1.1 Scraping pipe surfaces:
First clean the surface to be scraped with a clean lint-free dry cloth. The length to be
cleaned will depend on the size of the fitting to be used, adding a minimum additional
margin of 50 mm on each end.
Scrape the area of the pipe or pipes where the fitting to be joined will be installed. The
length of the scraping should be greater than that of the fitting.
IMPORTANT !
The scraping of the pipe should generate swarfs. This ensures the
elimination of the pipe’s most exterior oxidation, which would otherwise
lead to a dissatisfactory electrofusion joint.
Next clean the scraped area with a degreasing towel or with a clean, dry white cloth
(which does not shed lint), dampened with isopropanol or recommended PE solvent.
3.1.2 Fitting installation:
For joints of tapping saddles and branch saddles, place a rounder on each side of the
scraped area if the fusion is performed over a bar pipe. If the joint is performed over a
pipe from a roll, the placement of an aligner-rounder tool is indispensable. Next install the
fitting over the pipe.
If the fitting to be jointed is a coupler, reducer or elbow, remove it from its wrapping, and
without touching its interior, install it on the scraped and cleaned pipe. Now assemble the
aligner and the other specially-prepared pipe or fitting.
Electrofusion joints should only be carried out by qualified staff.
Protect the area where electrofusions area carried out
from adverse weather conditions, such as rain, snow
or wind. Admissible temperatures range from -5°C to
+45°C. In order to achieve a uniform temperature in
the whole diameter of the pipes, protect the fusion
area against sunrays or bad weather.
The quality of the joint depends substantially on the
care taken in the previous preparation tasks
(scraping, degreasing, etc).
Figure 8

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
- MODE OF USE Revision: No. 116
3.1.3 Unit connection:
Connect the unit to a 230 V ± 15%/50-60 Hz mains source (or to
a 110 V, according to market requirement) of alternating current.
For generator group specifications, please refer to CHAPTER 6:
TECHNICAL CHARACTERISTICS.
IMPORTANT NOTES !
Connection to a generator: the generator electric connection where
the control box mains is plugged must be normalized and fitted with
differential and ground pin. Refer to the generator’s User Manual.
Connection to the mains: the building electric installation where the
control box mains is plugged must be fitted with earth connection as
well as circuit breaker.
Do not unplug the mains pulling from the cable.
BEAT-2: connect the scanner before switching on the unit.
Checking the fitting connection cable terminals before starting up the
unit is advised. There are different types of adopters depending on the
type pf fitting to be used.
ØSet the master switch in the ON position.
BEAT-XX No.xxxx
V v.vv UK dd/mm/yy The display backlight will be enable, an acoustic signal
heard and the following information will appear:
BEAT-XX: model, BEAT-MV or BEAT-2
No.xxxx: unit serial number
V v.vv:softwareversion
UK: Letters of the active language
dd/mm/yy: current date
Once the display time has elapsed (3 seconds), the unit will display the following screen.
Possible initial messages:
TECHNICAL MACHINE SERVICE
If the programmed warning date for the Technical Machine Service in the unit has expired,
the display will show:
REV. VALID UNTIL
dd/mm/yy The unit will emit an acoustic signal and a message will
appear in the display along with the date of the next check.
If the date dd/mm/yy has not expired yet, press START to confirm and proceed to the
next screen (regardless of the existing locking set up of the unit).

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
Revision: No. 1 MODE OF USE - 17
If the date dd/mm/yy has already expired but the unit is set up without locking, by
pressing START you will be able to move to the next screen. However, if the unit is set
up with locking subsequently the unit will not be able to be used until the TMS has been
carried out.
AMBIENT TEMPERATURE OUT OF RANGE
If the ambient temperature is not within -20/C and 50/C [from software version v. 1.21
(previous software versions -15/C and 50/C)] or the temperature sensor is defective, with
data entry via bar code the following message will be displayed:
TEMPERATURE
OUT OF RANGE Pressing the key START/VALIDATE automatically
switches to manual mode.
NOTE: In the case of faulty probe, send the unit to the STPAcuster’s After-sale Service.
INTERNAL FAULT
If the software detects that there is a voltage output through the electrofusion cables out
of the electrofusion cycle, the display shows the following message:
SERIOUS TROUBLE
TURN OFF UNIT The unit will be blocked and the buzzer will be permanently
activated. Switch off immediately the unit.
NOTE: If case to have an electrofusion fitting connected, check if it has suffered damage.
Send the unit to the STPAcuster’s After-sale Service.
LOW BATTERY
In case to detect a battery voltage below the minimum required, the display will indicate:
SERVICE
FLAT BATTERY Send the unit to the STPAcuster’s After-sale Service for
the replacement of the battery.
Pressing the START button, the display shows the date and time to update it (refer to
paragraph DATE/TIME of section 3.2.4 of this Manual). This update will keep for some
time if the battery is not replaced, especially with the unit disconnected from the mains.
From the time the unit is started up, a verification of the input voltage is performed. If the
voltage registered by the unit is above or below the tolerance allowed (195-265 V for
nominal 230Vac and 90-140 V for nominal 110Vac ), one of the following messages will
appear on the display:
POWER SUPPLY ERROR
265/140V 65Hz Appears when the input voltage or frequency is over
265/140 Vac and 65 Hz, respectively.
POWER SUPPLY ERROR
195/90V 45Hz Appears when the input voltage or frequency is under
195/90 Vac and 45 Hz, respectively.
Check the power supply (generator) and correct the defect. It is not necessary to switch
the unit off and switch it on again to refresh the input voltage.

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
- MODE OF USE Revision: No. 118
3.1.4 Using the Barcode Reader (BEAT-2):
If you read the different data (operator’s ID, job ID, fittings, pipe, etc) by using optical
means (scanner), connect the reader device into the corresponding connector and put it
in front of the barcode data.
ATTENTION !
The scanner should be correctly setup. In case no data is captured by the
device, carry out the following barcode reading.
Software version
#
v. 1.23 Software version
$
v. 1.24
Laser scanner: When reading, the connected scanner emits a red laser line of a particular
length. To capture the barcode data, place the scanner so that the laser line coincides
longitudinally with the barcode. The distance will depend on the size of the barcode to
read. Once the scanner has been placed in position, the laser line will stop flashing and
remain fixed. When this happens, press any of the three buttons on the top of the
scanner.
Figure 9: Example of using the laser scanner

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
Revision: No. 1 MODE OF USE - 19
3.1.5 Fitting connection:
Connect the unit cable connectors in the fitting terminals to be jointed. The contact
surfaces of both the fitting’s terminals and the cable connectors must always be clean.
NOTE !
We advise you to always use adapters, even
though the connection to the fitting may be made
directly. Doing so, the cable terminals are
protected, do not wear out, burn, etc.
It is recommend refraining from electrofusion if the exterior temperature
is below -10/C or above +45/C.
3.1.6 Entering electrofusion data in the unit:
ÙBEAT-MV/BEAT-2:Entering joint data without barcode: via the keyboard.
BEAT-2 only: Click one of the 4 arrows. The display will show the following screen:
BEAT-2 23/C
FUSION DATA? Where 23/C corresponds to the ambient temperature
(informative).
Enter voltage. Press the ¨and §arrows to move the cursor to a different field and the
©and ªarrows to select the values.
FUSION DATA: 23ºC
VOLTAGE(Volt): $40.0 40.0 Volt by default.
The electrofusion voltage should be between 8 and 48 V.
Press START/VALIDATE to pass to the next screen.
Enter the time indicated by the fitting manufacturer, bearing in mind the correction given
according to the ambient temperature (according to the manufacturer). Press the ¨and
§arrows to move the cursor to a different field and the ©and ªarrows to select the
values.
FUSION DATA: 23ºC
TIME(s): $000 “0000" by default.
Maximum permitted time of 5940 seconds (99 minutes).
Press START/VALIDATE to pass to the next screen.
SCRAPED & CLEANED ?
<YES> Does not contemplate it being <NO>.

USER MANUAL
BEAT-MV/BEAT-2
Edition: January 2016
- MODE OF USE Revision: No. 120
Click the START/VALIDATE key. The following message will appear:
PRESS <START>
TO BEGIN Click the START/VALIDATE key to hear an acoustic
signal and the electrofusion cycle will begin.
ÏBEAT-2:Reading the fitting’s barcode using the scanner.
Read the fitting’s barcode with the scanner connected to the serial connector.
WARNING !
Make sure you always read the barcode corresponding to the fitting to be
electrofused. Should you not record the fitting’s data, this could cause
errors in the electrofusion process that would have repercussions on the
quality and reliability of the joint.
If the barcode or reading were incorrect.
FUSION DATA:
WRONG DATA Error message.
Two acoustic signals are emitted and it returns to the start.
When the data have been satisfactorily captured, the screen will show the following
message:
FUSION DATA: I AG
d20 40,0V 34s Information captured.
Where it involves a (I) Agru coupler of diameter 20, 40 Volt and 34 seconds (nominal).
Main symbols used (for the full list, please see ISO/TR 13950):
IMonofilar coupler YReducer
.t. Saddle TTee
[Single socket CElbow
Click the START/VALIDATE key to pass to the following screen.
SCRAPED & CLEANED ?
<YES> Does not contemplate it being <NO>.
Click the START/VALIDATE key. The following message will appear:
PRESS <START>
TO BEGIN Click the START/VALIDATE key to hear an acoustic
signal and the electrofusion cycle will begin.
If there is a malfunction in the electrofusion process, hot molten
PE/PP can be expelled in rare cases. Therefore, keep at a safe
distance from the fusion point during the electrofusion cycle and do
not connect any other electric equipment during the process.
This manual suits for next models
1
Table of contents
Other Global Industrial Equipment manuals

Global
Global ZZ 9567-75 User manual

Global
Global 316088 User manual

Global
Global SM 7830 AL Parts list manual

Global
Global WF3955-45DD Series Product guide

Global
Global SV 550 User manual

Global
Global 3995DD Series Product guide

Global
Global ZZ 1560 Series Troubleshooting guide

Global
Global 238CP28B2BK User manual

Global
Global WF 1767-AUT Parts list manual

Global
Global BEAT-Tr User manual