GORMAN-RUPP FILL-RITE 900CDP Series User manual

900CDP SERIES DIGITAL METER
Installation and Operation Manual

fillrite.com
2
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
Table of Contents
Thank You! ................................................................. 2
About This Manual ..................................................... 2
Safety Information ......................................................2
Installation .................................................................3
Meter Calibration ........................................................4
Procedure for Meter Calibration ..................................4
Operation Instructions ................................................5
Low Battery Warning ...................................................6
Storage .......................................................................6
Troubleshooting Guide ................................................6
Fluid Compatibility .....................................................7
Assembly and Disassembly ........................................ 7
Repair .........................................................................8
Safety Testing Approvals ............................................ 8
Replacement Parts Information ..................................9
900 Series Digital Meters w/ Pulser (w/ Barrier) .........9
900 Series Digital Meters w/ Pulser (w/o Barrier) .......9
Electrical Installation Information ............................10
Installation Using the Intrinsically Safe Barrier ........11
Meter Installation (w/o Intrinsically Safe Barrier) .....12
Reed Switch Information .......................................... 13
Technical Specifications and Information .................13
Specific Conditions of Use ........................................14
Certification Information .......................................... 14
Entity Parameter ...................................................... 15
Warranty Information ................................................15
Thank You!
Thank you for your purchase of the Fill-Rite 900
Series Digital Meter! Your Fill-Rite product comes
with over 80 years of fluid transfer experience behind
it, providing you the value that comes with superior
performance, user friendly design, long service life,
and solid, simple engineering.
For all product questions, please contact Fill-Rite
Technical Support at 1 (800) 720-5192 or via email
at FillRiteTech@fillrite.com (M-F, 8 AM – 5 PM ET).
About This Manual
From initial concept and design through its final production, your Fill-Rite meter is built to give you years of trouble free
use. To ensure it provides that service, it is critical that you read this entire manual prior to attempting to install or
operate your new meter. Become familiar with the terms and diagrams, and pay close attention to the highlighted
areas with the following labels:
Emphasizes an area in which personal injury or even death may result from failure to follow
instructions properly. Mechanical damage may also occur.
These boxes contain information that illustrates a point that may save time, or be key to
proper operation, or clarifies a step.
Failure to observe a “Caution” may cause damage to the equipment.
WARNING
CAUTION
NOTICE
DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
At Fill-Rite, your satisfaction with our products is paramount to us. If you have questions or need assistance with
your product, please contact us at 1 (800) 720-5192 or via email at FillRiteTech@fillrite.com (M-F, 8 AM – 5 PM ET).
Safety Information
This product is not suited for use with fluids intended for human or animal consumption or
fluids containing water. Nickel plated meters are approved for use with non-potable water,
antifreeze, certain agricultural chemicals, and other specialized water applications.
This product should not be used to transfer fluids into any type of aircraft.
WARNING
WARNING

fillrite.com
3
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
To insure safe and proper operation of your equipment, it is critical to read and adhere to
all of the following safety warnings and precautions. Improper installation or use of this
product can cause serious bodily injury or death!
1. NEVER smoke near the meter, or use the meter near open flames when metering a
flammable liquid! Fire can result!
2. A “Fill-Rite” Filter should be used on the meter outlet to insure no foreign material is
transferred to the fuel tank.
3. Threaded pipe joints and connections should be sealed with the appropriate sealant or
sealant tape to minimize the possibility of leaks.
4. Storage tanks should be securely anchored to prevent shifting or tipping when full
or empty.
5. To minimize static electricity build up, use only static wire conductive hose when
metering flammable fluids, and keep the fill nozzle in contact with the container being
filled during the filling process.
6. DO NOT exceed 50 psi/ 3.5 BARS line pressure.
7. DO NOT install additional foot valve or check valve without a pressure relief valve;
cracking may result.
WARNING
Installation
Threaded pipe joints and connections should be sealed with the appropriate sealant or
sealant tape to minimize the possibility of leaks.
CAUTION
If you have purchased this meter as part of a “Kit”, the meter flange base is drilled
with 4 holes. This allows the meter to be used with 300 and 700 series pumps. Line the
meter bracket up for installation and insert the bolts in the two holes that align with
the corresponding holes on the pump outlet. Once the meter bracket is bolted securely
in place install the two plugs in the holes that were not used to prevent moisture from
entering them.
NOTICE
Meters are furnished for horizontal piping; left to right flow.
Flow ports can be changed to any of four positions for horizontal or vertical
piping and for either direction of flow.
1. Determine direction for fluid to flow.
2. Install meter observing directional arrow on casting on back of
meter (circled). Liquid MUST flow in the direction of the arrow for
proper operation.
3. Remove four screws on corners of meter face (Torx T25 bit required).
4. Rotate meter face assembly to desired orientation.
5. Replace four screws.
6. Complete installation by making sure the joints are properly sealed
and meter is positioned for easy viewing and use.

fillrite.com
4
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
Meter Calibration
Meter calibration is required upon installation, after disassembly, after significant wear, or when dispensing a different
viscosity fluid. Calibration must be done between 6 and 40 GPM (23 and 151 LPM). Meter calibration can be easily
changed by following the calibration procedure. A container of KNOWN volume will be needed for the calibration procedure.
For the 900 Series Digital Meter, a five gallon container or larger, or a 20 liter container or larger should be used.
Procedure for Meter Calibration
Unit of measure and calibration is configured using a 3-step process:
1. Select the desired unit of measure.
2. Fill a container with a known volume using the desired fluid.
3. Enter the amount of fluid dispensed.
Prior to calibration, the unit must be placed in calibration mode. Simultaneously press and hold the CAL and TOTAL
buttons for 5 seconds to enter Calibration Mode.
When calibrating, the totalizers will not increase in value.
NOTICE
1. The unit will default to the last unit of measure used.
2. Press and release the TOTAL button to toggle through
the available units of measure.
3. Press and hold the CAL button for 2 seconds to move
to the next step.
4. If the meter is left untouched for 2 minutes or the
RESET button is pressed, the unit will automatically exit
Calibration Mode and ignore any changes in volume.
5. CAL 2 will be displayed.
6. Begin dispensing fluid into the container.
7. FILL will begin to blink after fluid flow is detected.
8. Dispense the desired amount fluid; stop flow as
soon as desired level is reached.
9. Press and hold the CAL button for 2 seconds to
move to the next step.
Dispensing into a container with a known volume allows the unit to automatically calculate
the internal scaling value to compensate for fluid viscosities and the system flow rate.
NOTICE
If left untouched for 2 minutes, or the RESET button is pressed, the meter will exit
Calibration Mode and any dispensed fluid will be ignored.
NOTICE

fillrite.com
5
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
11. The unit will default to a measured value based on the last calibration performed.
12. The left-most digit will begin blinking.
13. Use the TOTAL button to scroll from 0 to 9 until the
desired number has been selected.
14. Press and release the CAL button to move to the
next digit.
15. Repeat Steps 3 - 4 until the amount of dispensed
fluid has been entered.
16. If you make a mistake entering a digit, press and
release the CAL button repeatedly until the digit is
active again.
17. Press and hold the CAL button for 2 seconds to complete the calibration process regardless of the current
digit selected.
18. If at the last digit and the CAL button is pressed for less than 2 seconds, the process should roll back to the
left-most digit, but retain the current value. This allows the user to edit an incorrect value.
19. An error check for gross calibration errors (+/- 15%) will be performed unless USER units are selected. If an
error is detected, the meter will display Err0 until a button is pressed and the calibration process is aborted.
20. If the meter is left untouched for 2 minutes or the RESET button is pressed, the unit will automatically exit
Calibration Mode and ignore any changes.
Operation Instructions
For accurate measurement and to prevent meter damage, dispenser and piping must always be filled with liquid and be
free of air. The meter portion of your dispenser should be calibrated per instructions in this manual prior to its use.
The Fill-Rite 900 Series Digital Meter face incorporates three buttons that control all the operation and calibration functions.
To turn the display on, or wake the meter from “Sleep” mode, simply press any button on the face. The display will turn on
and you can proceed with the function you desire. Dispensing fluid will also turn the meter display on.
10. Pressing and holding the CAL button for 2 seconds before dispensing into a container will cause the meter to
skip a fill operation and only change the unit of measure.
For maximum accuracy, try to get as close as possible to the dispensed volume without
changing flow rate.
NOTICE
• The last count and selected totalizer is retained and displayed when the meter is turned on.
• Pressing and releasing the TOTAL button will switch between the resettable and non-resettable totalizers.
(The R icon will be displayed when the resettable total is displayed).
• Pressing and holding the RESET button for 2 seconds will
reset the counter.
• Pressing and holding the RESET button and TOTAL
buttons for 2 seconds will reset the totalizer. The
resettable totalizer must be active in order to
reset it.
• Pressing and holding the RESET button and CAL
buttons for 2 seconds will display the software version for 2
seconds and then perform a segment check for 3 seconds,
and then restore the display.
• Pressing and holding the CAL button for 5 seconds will
place the meter into a Deep Sleep mode. Pressing any
button twice will bring the meter out of deep sleep mode.
When the meter is in the “Deep Sleep” mode, dispensing fluid will NOT turn the meter on. The
meter will not display or accumulate any fluid that is dispensed while in “Deep Sleep” mode.
NOTICE

fillrite.com
6
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
• After 30 seconds of inactivity, the display will blank to conserve battery power.
• If the meter is connected to the external power source, the display will not blank unless forced into deep sleep mode.
• If external power is removed, the meter will revert to battery only operating characteristics and vice-versa.
• The counter and totalizer 2 can be reset even if fluid flow is detected. The meter will continue counting
during the 2 second RESET button press, then reset to 0, then resume counting.
“Deep Sleep” mode is designed to maintain a status of operational readiness while offering
battery conservation. The meter should be placed in this mode when:
• Flushing the unit so the dispensed volume is not counted.
• Traveling over rough surfaces (off-road) where fluid is being jostled and you
don’t want volume from the motion to be counted.
• Extending battery life; there is no penalty for repeatedly placing it in deep sleep.
NOTICE
Low Battery Warning
The digital display includes a “Low Battery” warning
indicator. When the battery reaches a level low enough
to require replacement, the display will show “BAT” as a
reminder to change the battery. When necessary, replace
batteries per procedure on page 7.
Concern Possible Concern Recommended Repair
Counter
inaccurate
Meter miscalibrated Check calibration and recalibrate as necessary (directions on
page 4).
Air in lines or metering chamber Check line seals and joints for leakage; seal leaks appropriately.
Measuring gears or disc
are sticking Clean or replace internal metering components as necessary.
Low flow
capacity Clogged meter chamber Clean meter chamber; clean or replace screens and filters
in piping.
Meter body
cracks Excess line pressure Install pressure relief valve to allow high pressure to bleed
back to the tank. Replace meter.
Nutating
Disc Broken
Sudden high pressure fluid
hitting disc
Avoid surge flows by installing a shut-off valve on outlet of
meter; install meter as close to the pump as possible, keep
piping full of liquid. Replace meter chamber assembly.
Storage
If your meter is to be stored for a period of time, clean it thoroughly. This will help protect the meter from possible damage.
Troubleshooting Guide
The following Troubleshooting Guide is designed to help you with basic digital diagnostics and repairs if you should
encounter abnormal service from your 900 Series Meter. We recommend you use only genuine Fill-Rite parts.
These parts, and additional service information is available through your authorized Fill-Rite dealer.
Further troubleshooting information can be found in your pump manual. If you need additional assistance, please
contact our Technical Support at 1 (800) 720-5192 or via email at FillRiteTech@fillrite.com (M-F, 8 AM – 5 PM ET).
To prevent possible ignition of flammable or explosive atmosphere DO NOT use a voltmeter,
or similarly powered tool or devicce during live maintenance.
WARNING

fillrite.com
7
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
If in doubt about compatibility of a specific fluid, contact supplier of fluid to check for
any adverse reactions to the following wetted materials:
Aluminum, Stainless Steel, Fluorocarbon, Polyester, Nickel, Acetal.
CAUTION
Figure 1
Fluid Compatilibity
The 900CDP Series Meter IS compatible with the following fluids:
Diesel Fuel, Bio-Diesel (up to B20), Gasoline, Kerosene, Mineral Spirits, Heptane, Hexane
The 900CDP Series Meter IS NOT compatible with the following fluids:
Bleach, Hydrochloric Acid, Ink, Sulfuric Acid, Salt Water
Assembly and Disassembly
The 900 Series Digital Meter consists of a chamber housing, measuring chamber, drive shaft, digital counter assembly,
and cover. The design of the meter is such that it can be completely disassembled without disturbing the piping (refer
to diagram on page 9).
Accessing the Batteries
For access to the batteries (2 AA cell batteries - Figure 1):
1. Remove the four screws at the top and bottom of the front bezel (Torx #T25).
2. Lift bezel off. Batteries are located on the back side of the display; use a Phillips head screwdriver to remove
the cover to access the batteries.
3. Reassemble by reversing this procedure.
To reduce the risk of explosion DO NOT mix old batteries with new batteries, or mix
batteries of different manufacturers.
WARNING
Batteries may ONLY be replaced with the following:
• Duracell MN1500 • Duracell MX1500 • Energizer E91
WARNING
To reduce the risk of ignition of a flammable explosive atmosphere, batteries MUST be
changed ONLY in a location known to be non-hazardous.
WARNING

fillrite.com
8
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
Meter Chamber Assembly
The Meter Chamber consists of upper and lower
chambers, a nutating disc, and four screws
(Figure 2).
1. To expose the meter chamber assembly
and seal remove the 4 screws.
2. The meter chamber can be
dislodged by removing the
4 screws (see Figure 2).
3. Reassemble by reversing this procedure.
If replacing any components of the meter chamber, the complete assembly must be
replaced due to its precision method of construction. This will assure a proper fit, and
correct operation of the chamber.
NOTICE
Figure 2
When returning a meter for service, it must be triple rinsed and accompanied by a note
stating what chemicals have been pumped through it.
Meters not adhering to these specifications may be refused for service.
NOTICE
Repair
Meters needing repairs should be taken to an authorized repair facility. Meters MUST be triple rinsed before taking
them in for repairs.
Safety Testing Approvals
The Fill-Rite 900CDP Series Meters have been tested for compliance to the standards set forth by Underwriters
Laboratories (UL), UL Canada, ATEX, and other testing organizations.
To determine which specific compliances apply to your particular meter, refer to the faceplate for information
and compliance logos (see “Certification Information” on page 14).

fillrite.com
9
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
Replacement Parts Information
Replacement parts can be obtained through any authorized Fill-Rite dealer. Be sure to use only genuine Fill-Rite
replacement parts for your service and maintenance needs.
900 Series Digital Meter Replacement Parts Kit
Kit Number # Description Qty
KIT900CDKT 1 Required Seal 3
2 Required Fasteners 6
3 Magnetic Driver 1
4 Chamber Assembly 1
KIT900CDPBA 5 Intrinsically Safe Barrier 1
5
900 Series Digital Meters with Pulser (with Barrier)
Certain 900 Series Digital Meters (model number suffix of CDP) can be powered externally and are equipped with an
integral electronic pulser unit for use with Fuel Management Systems.
The Fuel Management System must be configured for current sinking or contact closure types of signals. The meter
provides ten counts per unit of measure (in gallon, liter, and quart units of measure only; pulser does not operate in
ounce, pint, or user specific units of measure).
For installations in explosive atmospheres, the intrinsically safe barrier must be used. This barrier provides safe
electronic connection for all installations, and is mandatory where the meter is located in an area explosive fumes can
accumulate (i.e: minimum 20' circle around gasoline pumping equipment). Further information on intrinsically safe
barrier installations is located on page 11 and in the detailed wiring information included in the box with your meter.
900 Series Digital Meters with Pulser (without Barrier)
For meter installations not located in explosive atmospheres, the intrinsically safe barrier is recommended, but not
required. The barrier simplifies wiring and improves current sink and voltage quality, though the pulser in the meter
is designed to function directly with Fuel Management Systems using a current sink output with a maximum load of
20mA. Further information on non-barrier installations is located on page 12 and in the detailed wiring information
included in the box with your meter.
DANGER EXPLOSION RISK!

fillrite.com
10
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
Batteries may ONLY be replaced with the following:
• Duracell MN1500 • Duracell MX1500 • Energizer E91
WARNING
To reduce the risk of explosion DO NOT mix old batteries with new batteries, or mix
batteries of different manufacturers.
WARNING
Internal Power (Battery Power)
All 900CDP Series Digital Meters are battery powered. The battery tray is located behind the faceplate (see illustration
page 7). Power is supplied by two alkaline “AA” batteries. With normal use, these batteries should provide 2 – 4 years
of service. The digital display has an integral warning of low battery level (see page 6 for details).
Electrical wiring should be performed ONLY by a licensed electrician in compliance with
local, state, and national electrical codes (NEC/ANSI/NFPA 70, NFPA30, and NFPA 30A in
US installations for example), as appropriate to the intended use of the meter. The barrier
must be properly connected to an earth ground. Improper installation of this meter and
barrier can result in equipment failure or damage, serious bodily injury, or death!
WARNING
For meter installations using external power, the power should come from a dedicated
circuit. No other equipment should be powered by this circuit. Wiring must be of sufficient
size to carry the correct current for the meter. Voltage drop will vary with distance to meter
and size of wire; refer to the National Electrical Code (NEC), or local codes, for Voltage Drop
Compensation to be sure you are using the correct size wire for your application. Wiring
between the barrier and meter MUST NOT exceed 850'. Refer to “Typical Installation”
wiring information document DC000675-010 (included in the meter box) for details.
CAUTION
Explosion Proof versus Intrinsically Safe: There is a distinct difference between a product
that is “Explosion Proof” versus a product that is “Intrinsically Safe”. Intrinsically Safe
products do not generate enough heat or energy to cause ignition or explosion. They are
safe to use in an explosive atmosphere (i.e.: around fuel tanks, etc. where explosive vapors
may be present). Explosion Proof products are designed to contain an explosion internally
if one should occur. Understanding the difference between the two is critical when
installing a new item to be certain the installation is safe and to code.
NOTICE
External Power
900CDP Series Digital Meters can use an external power source to operate. Regardless of the source (AC or DC),
external power MUST be routed through the Intrinsically Safe Barrier any time the meter is installed in an
explosive atmosphere. External power sources MUST be within the rated parameters of the intrinsically Safe
Barrier and meter.
External AC Power
External AC power CANNOT be applied directly to the 900CDP meter. It must be routed through the Intrinsically
Safe Barrier regardless of meter installation location. The 900CDP Meter is not designed for direct AC power
input. See Intrinsically Safe barrier wiring information on page 11 for additional information.
External DC Power
The 900CDP meter can be powered directly by an external DC power source (such as a Fuel Managment System) that
operates within the meters parameters. The Intrinsically Safe Barrier MUST be used anytime the meter is installed in an
explosive atmosphere. For additional information on non-barrier installations, see page 12.
Electrical Installation Information
There are multiple electrical configurations for the 900CDP Series Digital Meter, featuring two different power sources.
It is critical that the meter be installed and wired correctly to ensure correct, safe operation.

fillrite.com
11
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
Installation Using the Intrinsically Safe Barrier
Substitution of components will impair intrinsic safety!
WARNING
The instructions on this page are intended as an introduction to the proper wiring
procedure for the Series 900CDP Digital Meter. Detailed wiring instructions and
information are included in the 4 page document labeled: “FILL-RITE SERIES 900CDP
METER, INTRINSICALLY SAFE FLOWMETER” (control drawing DC000675-000), included
in the box with your meter. These instructions MUST BE READ AND UNDERSTOOD
COMPLETELY PRIOR to installation. See “WARNING” under “Electrical Installation
Information” on page 10 prior to beginning installation.
WARNING
To prevent ignition of flammable or combustible atmosphere, do not use a volt meter or
similar powered tools during live maintenance.
WARNING
To prevent ignition of combustible or flammable atmosphere, disconnect power
before servicing.
WARNING
Intrinsically Safe Barrier must be housed in a environmentally safe container.
WARNING
900CDP Battery
and Wiring Access
Intrinsically
Safe Barrier
The Intrinsically Safe Barrier is designed to work with
the following incoming power sources:
12 - 40V DC
or
90 - 240V AC, 50 - 60 Hz
(US: 120V AC, 60Hz, Load Neutral Ground)
(EU: 230V AC, 50Hz, Load Neutral Ground)
A) Output to Meter
Power: +
Power: -
Pulser Signal
B) Output to FMS
1 - Output
2 - Unused
3 - Output
A
C) AC Power Input
Line
Ground
Neutral
D) DC Power Input
DC+
DC-
DB C

fillrite.com
12
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
Meter Installation (without Intrinsically Safe Barrier)
For meters that are not installed in explosive atmospheres, the intrinsic safety barrier is recommended, but not
required. The barrier simplifies the wiring and improves the quality of voltage and current absorption. The meter
pulser is designed to work directly with fuel management systems through a current sink output of up to 20mA.
The Series 900CDP Digital Meter can be wired directly to an external DC power source that operates within the
meters parameters (7.5 - 28V DC, .2A). Any external power sources should be clean DC from a dedicated circuit. The
connections are made at the terminals on back of the meter. Note the three connections; “+” and “-” for external DC
power, and “S” for pulser signal.
The instructions on this page are intended as an introduction to the proper wiring
procedure for the Series 900CDP Digital Meter. Detailed wiring instructions and
information are included in the 4 page document labeled: “FILL-RITE SERIES 900CDP
METER, INTRINSICALLY SAFE FLOWMETER” (control drawing DC000675-000),
included in the box with your meter. These instructions MUST BE READ AND
UNDERSTOOD COMPLETELY PRIOR to installation. See “WARNING” under
“Electrical Installation Information” on page 10 prior to beginning installation.
WARNING
EXPLOSION RISK!
DANGER
DO NOT install the Series 900CDP meter in explosive atmospheres without the
Intrinsically Safe Barrier!
WARNING
Three wire cable coming into the meter should be limited
to only as much as is necessary to complete the wiring.
Excess wiring should not be left inside the meter.
Auxilliary power and pulser connection
at meter. Note three connections:
DC+, DC-, and Pulser Signal.

fillrite.com
13
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
Dimensions:
6.75" (H) x 8.46" (W) x 4.10" (D)
Accuracy: ± 1.25 %
Repeatability:
± 0.25% at calibrated flow rate.
Flow Rate: 6 to 40 GPM
Pressure Rating: 50 psi
Construction: Aluminum
Units of Measure:
ounces, pints, quarts, liters, gallons,
1 special “Unit of Measure” option
Counter: 4 digit resettable counter; (.01 – 9999 units)
Totalizers: 7 digit non-resettable “Master” totalizer, 7-digit resettable secondary
Mounting Options: Can be installed for vertical or horizontal mounting by rotating display accordingly
Approvals: UL / cUL / ATEX Listing (see page 6 for information on specific certifications)
Power Supply: 2 “AA” batteries (Dura-cell MN1500, MX1500, or Energizer E91 Alkaline batteries only); optional
external power through Intrinsically Safe Barrier.
Expected Battery Life: 2 - 4 years of normal use with standard Alkaline batteries
Operating Temperature Range: -40° to 140°F (-40° to 60°C).
Specific conditions of use:
• The Series 900CD, and 900CDP may be used with only Part No. MN1500 or MX1500 cells manufactured by Dura-
cell or Part No. E91 cells manufactured by Energizer.
• The housing of the Series 900 meters is made of powder coated aluminum. Care must be taken in the end use
to ensure coating does not wear away to expose bare metal or that the device must be used only in applications
where it is protected from friction sparking.
• The Remote Reed Switch Assembly Part No. SA000048-005 is provided with a non-metallic housing material.
Care must be taken to avoid ignition hazards due to potential electrostatic charging hazard.
Reed Switch Information (cabinet model only)
CONDITIONS FOR SAFE USE: The Remote Reed Switch Assembly Part No. SA000048-005 is
provided with a non-metallic housing. Care must be taken to avoid ignition hazards due to
potential electrostatic charging hazard.
WARNING
Technical Specifications and Information

fillrite.com
14
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
The following information is provided in compliance with UL standards to define specific safety parameters under
which this appliance must be operated.
The Series 900CDP Meters may be used in an ambient temperature range of -40ºC to +60ºC.
The housing of the Series 900CDP Meter is made of powder coated aluminum. Care must be taken in installation
to make sure the powder coated aluminum meter case does not wear away to expose bare metal, or that it is not
installed where friction sparking may occur.
Specific Conditions of Use
Batteries may ONLY be replaced with the following:
• Duracell MN1500 • Duracell MX1500 • Energizer E91
Incorrect battery selection presents a safety hazard.
WARNING
CONDITIONS FOR SAFE USE: The Remote Reed Switch Assembly Part No. SA000048-005
is provided with a non-metallic housing. Care must be taken to avoid ignition hazards due
to potential electrostatic charging hazard.
WARNING
Certification Information
The following is a list of standards used to attain certification:
• IEC 60079-0, 7th ed.,
• EC 60079-11, 6th ed.,
• EN IEC 60079-0:2018
• EN 60079-11:2012,
• CAN/CSA C22.2 No. 60079-0:15,
• CAN/CSA C22.2 No. 60079-11:14,
• UL913, 8th ed.,
• UL60079-0, 5th ed.,
• UL 60079-11, 5th ed.,
• CAN/CSA C22.2 No. 157-92. (Rev 2016)

fillrite.com
15
INSTALLATION AND OPERATION MANUAL
| 900CDP DIGITAL METER
Entity Parameter
The Series 900CDP Meter has the following entity parameters:
Ui = 13.65 V Ii = 0.319 A Pi = 1.343 W Li = 0 mH Ci = 16.4uF
Substitution of components will impair intrinsic safety!
WARNING
To prevent ignition of flammable or combustible atmosphere, do not use a volt meter or
similar powered tools during live maintenance.
WARNING
To prevent ignition of combustible or flammable atmosphere, disconnect power
before servicing.
WARNING
Warranty Information
Your quality Fill-Rite product carries a full manufacturers limited warranty. For terms and conditions of that
warranty please visit fillrite.com. Fill-Rite recommends you retain your sales receipt as proof of purchase.

Fill-Rite Company
8825 Aviation Drive
Fort Wayne, Indiana 46809 USA
T 1 (800) 720-5192
1 (260) 747-7524
F 1 (800) 866-4681
fillrite.com | sotera.com | gormanrupp.com
DC001501-000 Rev. 5