NP400 Pressure Transmitter
NOVUS AUTOMATION 2/2
Influence of the Mounting Position:
< 0.001 % of Maximum Range / °C.
Output Signal (Output):
Electric current, 4-20 mA, 2 wires.
Maximum current < 21.5 mA.
Resolution:
< 0.1 % of Maximum Range.
Power Supply (Power):
11 to 33 Vdc
Maximum Load (RL):
RL = (Vdc - 11) / 20 mA (Ω)
Where: Vdc = Power supply voltage
Electrical Connection:
Connector for Type A valves (DIN EN 175301-803), IP65.
Conductor 1.5 mm² (max.) and cables between 6 and 8 mm in
diameter.
Operating Temperature:
-20 to 70 °C (-4 to 158 °F)
Medium Temperature:
-20 to 100 °C (-4 to 212 °F)
Storage Temperature:
-40 to 70 °C (-40 to 158 °F)
Dynamic Response:
< 1 ms
Process Connection (Thread):
¼ NPT; ½ NPT; ½ BSP; G ¼ (*)
Sensor Features:
Piezoresistive – Thick Film on Ceramics (Al2O396 %).
Metal housing of the Transmitter:
Stainless steel 316.
Wetted parts:
Sensor Ceramic, Al2O396 %.
Sealing Ring, FKM.
Metal Connection, stainless steel 316.
Compatibility: Any gas or liquid compatible with the constituent
materials of the wetted parts.
Certification: CE
(*) Information available on the product identification label.
Note: For models with process connection ½ BSP and G ¼, the
outer seals are manufactured with FKM.
ELECTRICAL CONNECTIONS
Fig. 2 – Electrical connections
Installation recommendations
•The instruments must be powered from a dedicated
instrumentation power supply.
•It is strongly recommended to apply RC'S FILTERS (noise
suppressor) to contactor coils, solenoids, etc.
•To improve measurement stability, immunity and safety, it is
recommended to use system grounding.
DIMENSIONS
Fig. 3 – Transmitter dimensions
Note: Previous versions (2020) have other measures.
THREAD
A (mm) B (mm) WEIGHT (g)
NPT ¼ 15.5 51.0 106
NPT ½ 20.0 56.5 159
BSP ½ 14.0 49.5 121
G ¼ 14.0 49.5 105
Table 2 – Transmitter thread type, dimensions, and weight