3A7033B
EN
Installation
InvisiPac®Sift-Proof
Nozzle Kits
For dispensing hot melt adhesive from an InvisiPac GS35 Plug-Free™Applicator to create
a sift-proof seal. For professional use only.
See page 2for kit information.
Important Safety Instructions
Read all warnings and instructions in this
manual and in all related manuals before
using the equipment. Save all
instructions.
Related Manuals
2 3A7033B
Contents
Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Pressure Relief Procedure . . . . . . . . . . . . . . . . . . 3
Installation Steps . . . . . . . . . . . . . . . . . . . . . . . . . 3
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Kits and Accessories . . . . . . . . . . . . . . . . . . . . . . . . 4
Related Manuals
These manuals are available at www.graco.com.
Kits
Overview
These instructions are for installing a sift-proof nozzle to
an InvisiPac GS35 Plug-Free Hot Melt Applicator. These
nozzles are intended for applications that require
sealing a box or other container to prevent granular
material from sifting through cracks.
The nozzles repeatedly dispense six simultaneous hot
melt adhesive shots onto the flaps of a box. When the
box is pressed together, the adhesive shots blend into a
continuous bead to seal the box and prevent material
from leaking out of it.
The sift-proof nozzles are for use with InvisiPac
Sift-Proof GS35 Plug-Free Hot Melt Applicators only.
Select the appropriate kit based on the tip size you need
for your application. See Kits on this page.
Sift-proof nozzles require a GS35 sift-proof module for
installation, part no. 25E616. Refer to the Module Repair
Kit Instructions. See Related Manuals on this page.
Contact Graco Ohio Technical Assistance at
800-746-1334 or [email protected] for additional
information or assistance with this kit.
Part Description
3A4938 InvisiPac®HM25c Hot Melt Delivery System, Instructions-Parts
333347 InvisiPac®HM25 and HM50 Tank-Free™Hot Melt Delivery System, Instructions-Parts
3A2805 InvisiPac®GS35 Plug-Free™Hot Melt Applicator, Instructions-Parts
407050 Module Repair Kit Instructions
Sift-Proof Nozzle Kits Replacement Tip Kits
Part No. Tip Size (in.) Description Part No. Tip Size (in.) Description
25E605 .018
Assembled sift-proof nozzles.
See Parts on page 4.
25P230 .018 Optional kits for replacing tips
in the nozzle. Includes six tips
and a tool for removing and
installing the tips.
25E606 .020 25P231 .020
25B207 .022 25P228 .022
25E607 .024 25P232 .024
25E604 .026 25P229 .026
25E608 ---
Installation
3A7033B 3
Installation
Pressure Relief Procedure
1. Turn off the InvisiPac main power switch.
2. Close the bleed-type master air valve.
3. Actuate the applicator repeatedly until no fluid flows.
4. If you suspect the current module nozzle is clogged,
remove the nozzle and actuate the module to
relieve pressure.
5. If you suspect the module or fluid hose is clogged or
that pressure has not been fully relieved after
following the steps above, very slowly loosen the
inlet fitting, inlet filter, or hose end coupling to
relieve pressure gradually. Then loosen it
completely. Clear the hose or module obstruction.
6. Turn off air pressure to the solenoid valve.
Installation Steps
NOTE: The GS35 sift-proof module (Kit no. 25E616) is
required for installing the sift-proof nozzle.
1. Follow the Pressure Relief Procedure.
2. Refer to the Module Repair Kit Instructions to install
Kit 25E616. See Related Manuals on page 2.
3. Refer to Figure 1 and place the o-ring (2) included
in the kit on the back of the nozzle (1). See Parts on
page 4.
4. Attach the nozzle (1) to the module using the two
screws (3) provided in the kit as shown in Figure 2.
Torque the screws to 1.5-2.5 in-lbs (.17-.28 N•m).
5. Turn the main power switch on.
WARNING
BURN HAZARD
Equipment surfaces and fluid that is heated can
become very hot during operation. To avoid severe
burns, wear protective equipment and do not touch
hot fluid or equipment.
WARNING
PRESSURIZED FLUID HAZARD
The equipment in this system stays pressurized until
pressure is manually relieved. To help prevent serious
injury from pressurized fluid, such as skin injection,
splashing fluid, and moving parts, follow the Pressure
Relief Procedure when you stop pumping and before
cleaning or servicing the equipment.
ON
OFF
FIG. 1: Attach O-Ring
FIG. 2: Install Nozzle
1
2
3
1
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents.
Original instructions. This manual contains English. MM 3A7033
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2018, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
Revision B, May 2021
Parts
Sift-Proof Nozzle Kits
--- Not available for individual sale.
Depends on nozzle size. Refer to Kits on page 2.
Kits and Accessories
Sift-Proof Nozzle Guard, 25R756
The nozzle guard includes hardware to mount to a
single GS35 sift applicator to protect sift-proof nozzles.
Graco Information
For more information about InvisiPac, visit www.InvisiPac.com or email [email protected].
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
For technical assistance or customer service, call toll free: 1-800-458-2133.
FIG. 3: Nozzle Kit Parts
Ref. Part Description Qty.
1 ---NOZZLE, assy, sift 1
2 130794 O-RING, 13 mm id x 1 mm, viton 1
3 130747 SCREW, shc, m4 x 0.7 x 8 mm, sst 2
1
3
2
FIG. 4: Nozzle Guard

This manual suits for next models

4

Other Graco Melting Machine manuals

Graco THERM-O-FLOW T7 Series User manual

Graco

Graco THERM-O-FLOW T7 Series User manual

Graco Therm-O-Flow 200 Parts list manual

Graco

Graco Therm-O-Flow 200 Parts list manual

Graco InvisiPac GM100 Plug-Free User manual

Graco

Graco InvisiPac GM100 Plug-Free User manual

Graco Therm-O-Flow 20 Parts list manual

Graco

Graco Therm-O-Flow 20 Parts list manual

Popular Melting Machine manuals by other brands

LYSON W4805 instruction manual

LYSON

LYSON W4805 instruction manual

Nordson 3930 manual

Nordson

Nordson 3930 manual

Nordson ProBlue P4 Customer product manual

Nordson

Nordson ProBlue P4 Customer product manual

Cole Parmer MP-400 Series instruction manual

Cole Parmer

Cole Parmer MP-400 Series instruction manual

Viega ProRadiant Basic Digital Snow Melt Control... Product instructions

Viega

Viega ProRadiant Basic Digital Snow Melt Control... Product instructions

Rapid EG PEN operating instructions

Rapid

Rapid EG PEN operating instructions

Electrothermal IA9000 SERIES Instruction book

Electrothermal

Electrothermal IA9000 SERIES Instruction book

Stuart SMP11 Instructions for use

Stuart

Stuart SMP11 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.