grado RM210 User manual



1. Close supervision is necessary when the
thermometer is used by, on, or near children,
handicapped persons or invalids.
2. Use the thermometer only for the intended use
described in this manual.
3. Do not use the thermometer if it is not working
properly, or if it has suffered any damage.
4. Do not use accessories which are not supplied
or recommended by the manufacturer.



As with any thermometer, proper technique is crucial to
getting accurate temperature readings.
Always store the thermometer in a cool and dry place:
temperatures between -20C° to 60C° relative humidity
less than 95%.
the thermometer from a height or
strongly hitting it with a hard object.
Only use the lens lter for infrared CLEVER TD-1261 ear
thermometer.
For proper hygiene, do not share lens filter. Damaged
lens lter may result in error display.
Do not disassemble the thermometer.
Basic safety precautions should always be observed,
especially when the thermometer is used on or near
children and disabled persons.
This thermometer is not intended to be a substitution
for consultation with your physician.
Keep lens lters out of reach of children.
Temperature of left and right ear may differ. Always
measure using same ear.

This thermometer is clinically proven to produce accurate
temperature measurements. However, please be advised if
you have the following situations:
The accuracy cannot be ensured for a person who has
deformity in the ear such that the thermometer probe
can not be properly inserted into the ear canal.
The accuracy cannot be ensured when blood or drainage
is found in the ear canal.
Take temperature from the other ear if ear drops or
medications have been placed in an ear.
For a person who wears ear plug or hearing aid, remove
the device and wait for 15 minutes before taking
temperature.

Thank you for choosing RM210 infrared ear thermometer
GRADO by Moretti Spa. This innovative medical device
relies on on advanced infrared (IR) technology to measure
temperature instantly RM210 ear thermometer is an
elegantly designed infrared thermometer meant for your
family.
RM210 infrared ear thermometer is intended for the
intermittent measurement and monitoring of human body
temperature from ear canal. The device is intended for use
by people of all ages in the home.

The thermometer measures the infrared heat generated by
the eardrum and its surrounding tissue. The thermometer
then converts it into a temperature value shown on LCD.
The ear infrared thermometer GRADO by Moretti Spa is in
accordance with the following regulation:
EN 980
EN 1041
EN 12470 - 5
EN 60601 - 1
EN 60601 - 1 - 2

Lens Filter
RM210
Ear Thermometer
Two 1.5V AAA
Batteries
User’s Manual
Storage Case

1
2
3
4
6
7
8
5
29
10
1
2
3
4
6
7
8
9
10
5
Lens lter
Lens lter ejection button
On/Memory button
Sticker
Battery cover
Data port
Probe lens
Probe
Lens lter detector
Scan button

19
7
210
6
3
5
4
8

1
2
3
4
6
7
8
9
10
5
Ear temperature indicator
Non-lens lter warning
Temperature scanning in progress
Temperature display
Memory mode
Record numbers
Low battery indicator
Temperature unit
Temperature indicator for memory
mode
Communication symbol

The thermometer comes with two 1.5V AAA alkaline
batteries. Replace it when “ ” appears. Please follow
the steps to replace new batteries.
Remove the battery cover.
Place the new battery in the
battery compartment and press
it in until the battery is firmly
secured.

Reattach the battery cover.

Body temperature can vary from one individual/person to
next. It also varies by location on the body and different
time of the day. Below shows the statistical normal
ranges from different sites. Please keep in mind that
temperatures measured from different sites, even at the
same time, should not be directly compared.
Fever indicates that the body temperature is higher than
normal. This symptom may be potentially caused by
infection, overdressing or immunization. Some people
may not experience fever even when they are ill. These
include, but are not limited to, infants younger than 3
months old, persons with compromised immune systems,
persons taking antibiotics, steroids or antipyretics (aspirin,
ibuprofen, acetaminophen), or persons with certain
chronic illnesses.
Oral 35.5C° - 37.5C° (95.9F° - 99.5F°)
Axillary
(underarm)
34.7C° - 37.3C° (94.5F° - 99.1C°)
Rectal 36.6C° - 38.0C° (97.9C° - 100.4C°)
Ear 35.8C° - 38.0C° (96.4F° - 100.4F°)

Check the lens lter is clean
and new.
Attach new lens lter into the probe.

Make sure lens lter is rmly
attached to the probe.
Press and release the On / Memory
button to turn on the thermometer.
When ready, the thermometer
displays the last measurement.
Gently t the probe into the ear
canal.

Press and release the Scan button.
Do not remove the thermometer
until it beeps.
Read the result.
“ ” is shown together with a
temperature value.
Discard used lens lter into trash by
pressing lens lter ejection button.

1. As with other of thermometer, you may observe
slight variations in consecutive measurements.
Infants younger than 3 months old.
Children younger than 3 years old and who have a
compromised immune system and the presence /
absence of fever is critical.
When you are learning to use the thermometer.
2. Do not take a reading while eating and /or talking. Wait
30 minutes after any of the following situations before
taking a measurement:
When you have your ear covered.
After exercising, swimming, or taking a bath. When
expose to extreme temperature.
3. To take accurate readings, the ear must be free from
excess earwax build-up.
Table of contents
Other grado Thermometer manuals