Grandhall THD1500EU Instruction manual

M A N U F A C T U R E D B Y T H E R M O F I L M A U S T R A L I A
D I S T R I B U T E D B Y G R A N D H A L L E U R O P E R e v A M A R 1 2
THD HEATSTRIP: ELECTRIC RADIANT OUTDOOR HEATER
INSTALLATION, OPERATION &
MAINTENANCE MANUAL
(EUROPE /ENGLISH)
THD HEATSTRIP MODEL CODES
MODELS WATTS DIMENSIONS RATING
THD1500EU 1500 924 x 165 x 48 230V 50Hz a.c
THD2400EU 2400 1475 x 165 x 48 230V 50Hz a.c
THD3200EU 3200 1950 x 165 x 48 230V 50Hz a.c
THD1500UK 1500 924 x 165 x 48 240V 50Hz a.c
THD2400UK 2400 1475 x 165 x 48 240V 50Hz a.c
THD3200UK 3200 1950 x 165 x 48 240V 50Hz a.c
Note: THD series HEATSTRIPS have an IP55 rating for protection against water ingress.
Prior to installing and operating the heater, read these instructions carefully and retain for future
reference.
PREPARATION
1.The THD Series HEATSTRIPS are high intensity Radiant Strip Heaters designed for Do estic /
Co ercial heating applications within indoor or outdoor undercover areas, and should not be used
for any other purpose.
2.Before co encing installation, ake sure the electrical supply voltage is the sa e as that shown on
the rating plate of the heater.
3.The heater is fitted with a length of flexible cable for electrical connection. The heater should be
connected as a fixed installation by a licensed electrical person, according to the relevant electrical
standards.
4.All pole disconnection fro the supply ains ust be provided in fixed wiring in accordance with the
wiring rules.
5.This appliance ust be earthed.
6.The heater is required to be fitted with an “ON/OFF isolation switch and can also be controlled via
ther ostat, ti er or di er type control. A wall switch should be installed on fixed wire
installations. Optional connection to an R.C.D is reco ended.
7.If the supply lead is da aged, the appliance should be scrapped. In case of heater fault, the appliance
ust be returned to the distributor / anufacturer for repair.
INSTALLATION LOCATION
For both wall and ceiling ounting, the lowest part of the heater ust be located a ini u of
2100
above floor level.
The heater ust not be closer than 1000 to adjacent walls, with a ini u of 60 between back
of heater and any surface.
Allow 1000 fro the botto of the heater to any surface below.
Do not allow ther al insulation, cables, fla able aterials or any other ite s to co e into contact
with any surface of the heater; purpose design brackets excluded.
The heater ust not be located i ediately below a socket outlet.
If installed in wet areas, the heater ust be installed so that switches and other controls cannot be
touched by persons in the bath or shower.

M A N U F A C T U R E D B Y T H E R M O F I L M A U S T R A L I A
D I S T R I B U T E D B Y G R A N D H A L L E U R O P E R e v A M A R 1 2
MOUNTING INSTRUCTIONS
•Using the centre distances shown in “B”, ount the brackets to the ceiling or wall.
•Ensure fixing ethod will adequately support weight of heater.
•Then, fix brackets to heater with the silicon strip in place and secure the brackets, using the screws
provided on the brackets to tighten.
•Ensure screw fixing two halves of bracket is fully tightened.
•Use the two screws to lock the two halves of the bracket at the desired angle.
•The heating surface ust never be directed toward the ceiling.
•
The power cable ust be at the lower end of the heater if the heater is installed at an angle.
MODEL “B”
MINIMUM DISTANCE
(mm)
THD1500A 550
THD1800A 710
THD2400A 1330
THD3200A 1470
B
TAKE SILICON
STRIP
BEND IN HALF
FOLD OVER
LOWER SIDE
OF BRACKET
PUSH
BRACKET AND
SILICON STRIP
INTO SLOT IN
CASING

M A N U F A C T U R E D B Y T H E R M O F I L M A U S T R A L I A
D I S T R I B U T E D B Y G R A N D H A L L E U R O P E R e v A M A R 1 2
OPERATION INSTRUCTIONS
TO BE KEPT BY THE USER OF THIS APPLIANCE
The heater is required to be fitted with an “ON/OFF” isolation switch and can also be controlled via
ti er type control.
Once the unit is turned On via a switch or other control device, it will take approxi ately 10 inutes
to war up to nor al operating te perature.
Make sure the unit is turned OFF after use.
Note: THD series HEATSTRIPS have an IP55 rating for protection against water ingress.
CAUTION
•The front panel of the heater can reach te peratures of up to 380°c.
•Do not touch any part of the heater while in operation or for 30 inutes after turning off.
•This appliance is not intended for use by young children or infir persons.
•Caution ust be exercised when operating this appliance.
•Do not allow any cables, furnishings, fla able aterials or other ite s to co e into contact with
any surface of the heater.
•The heater ust have a ini u 1000 clearance to adjacent walls and ini u 60 clearance
fro the back of the heater to any ounted surface.
•Do not operate heater unless there is a clearance of 1000 or ore fro botto of the heater to
any surface below.
•The heater should be connected as a fixed installation by a licensed electrical person, according to the
relevant electrical standards.
•All pole disconnection fro the supply ains ust be provided in fixed wiring in accordance with the
wiring rules.
•The heater ust not be located i ediately below a socket outlet.
•If installed in wet areas, the heater ust be installed so that switches and other controls cannot be
touched by persons in the bath or shower.
•If the supply lead is da aged, the appliance should be scrapped.
•In case of heater fault, the appliance ust be returned to the distributor / anufacturer for repair.
CLEANING & GENERAL MAINTENANCE
It is i portant that THD
HEATSTRIP units installed in outdoor locations are regularly cleaned to ensure
a long and efficient operating life.
In coastal locations in particular, salt in the air can cause rusting and staining of etal. Even in city
locations, pollution in the air can also conta inate surfaces and will affect the ability of the coatings and
aterial of your THD HEATSTRIP to protect fro rust and stains.
As the THD HEATSTRIP has a protection rating for water ingress of IP-55, they can be safely washed
and cleaned with water.
The heater can be lightly sprayed with a hose, but the preferred ethod of cleaning is to rinse the
heaters using a soft cloth with war water and a ild detergent. Ensure any soap residue is rinsed off
after cleaning.
CAUTION:
•Before any cleaning activity, the heater ust be switched off and cooled down co pletely. (The
heaters can be turned on briefly after washing to dry the off quickly.)
•DO NOT use a high pressure hose or high pressure water equip ent to clean the heaters.
•As a guide, THD HEATSTRIP units should be cleaned whenever you are cleaning the outdoor
furniture in the sa e area. In coastal areas, an additional rinsing on a fortnightly basis with a light
spray fro a hose will provide extra protection.

M A N U F A C T U R E D B Y T H E R M O F I L M A U S T R A L I A
D I S T R I B U T E D B Y G R A N D H A L L E U R O P E R e v A M A R 1 2
DISTRIBUTOR DETAILS FOR
EUROPE /UNITED KINGDOM
Gran Hall Europe B.V.
Zwollestraat 15
7575 DB Oldenzaal, The Netherlands
Tel +31 0 541 531669
Fax +31 0 541 534563
grandhall@grandhall.eu

M A N U F A C T U R E D B Y T H E R M O F I L M A U S T R A L I A
D I S T R I B U T E D B Y G R A N D H A L L E U R O P E R e v A M A R 1 2
Montage – un Gebrauchsanleitung
EUROPE - DEUTSCH
THD HEATSTRIP MODELLNUMMERN
Mo ell Watt Maße Leistung
THD1500EU 1500 924 x 165 x 48 230V 50Hz a.c
THD2400EU 2400 1475 x 165 x 48 230V 50Hz a.c
THD3200EU 3200 1950 x 165 x 48 230V 50Hz a.c
THD1500UK 1500 924 x 165 x 48 240V 50Hz a.c
THD2400UK 2400 1475 x 165 x 48 240V 50Hz a.c
THD3200UK 3200 1950 x 165 x 48 240V 50Hz a.c
Beachten Sie bitte : Der HEATSTRIP ist spritzwasser geschützt (Kennziffer IP55)
Vor er Installation lessen Sie bitte folgen e Anweisung sorgfältig urch.
Vorbereitung
1. Die HEATSTRIPS sind hochintensive Strahlungsheizer, die als häusliche oder
ko erzielle Heizgeräte für den überdachten innen – oder Außenbereich konzipiert
sind und nicht für andere Zwecke genutzt werden sollten.
2. Bevor Sie it der Montage beginnen, üssen Sie sich versichern, dass die
Betriebsspannung dieselbe ist wie diejenige, die auf de Leistungsschild des
Strahlungsheizers angegeben ist.
3. Der Heizer ist ausgestattet it eine Kabel für den elektrischen Anschluss. Das
Heizgerät sollte als seine fest fixierte Installation von eine Elektriker angeschlossen
warden, der dies nach den bestehenden elektrischen Standards durchführt.
4. Die Anschlüsse an die Hauptstro versorgung üssen nach den offiziellen
Verkabelungsregeln erfolgen.
5. Das Gerät uss geerdet sein.
6. Der HEATSTRIP sollte it eine “ON/OFF” – Schalter ausgestattet werden. Man
kann ihn jedoch ebenfalls ittels Ther ostat oder Di er steuern. Ein optionaler
Anschluss an einen Fehlerstro schutzschalter wird e pfihlen.
7. Ist das Netzkabel beschädigt, so uss das Gerät entsorgt werden. Ein defektes
Heizgerät uss an den Großhändler/Hersteller zur Reparatur zurückgesandt werden.
Installationsort
•
Für Decken – als auch Wand ontage uss das Gerät indestens 2.10 über de
Boden angebracht werden.
•
Der Heizer uss einen Mindestabstand von 300 zu jeder angrenzenden Wand und
6c zur rückwärtigen Montieroberfläche haben.
•
Lassen Sie einen Mindestabstand von 1 zu jeder Oberfläche unter ih .
•
Achten Sie darauf, dass weder Wär edä stoffe, noch Kabel, Möbel, brennbare
Materialien oder andere Gegenstände it der Oberfläche des Strahlunsheizers in
Kontakt ko en.
•
Der Heizer darf nicht direkt unterhalb einer Steckdose angebracht werden.
•
Wenn der HEATSTRIP in eine feuchten U feld ontiert wird, üssen die Schalter
oder anderen Bediengeräte so angebracht werden, dass sie nicht von Personen, die
sich i direkten Kontakt it Wasser befinden, berührt werden können.