GRASS VALLEY K2 BASECAMP EXPRESS User manual

K2
Storage
SAN and Direct-Connect
Cabling Guide
071-8713-00
September 2009

Affiliate with the N.V. KEMA in The Netherlands
CERTIFICATE
Certificate Number: 510040.001
The Quality System of:
Thomson Inc, and it’s wordwide Grass Valley division affiliates DBA
GRASS VALLEY
Headquarters
400 Providence Mine Rd
Nevada City, CA 95959
United States
15655 SW Greystone Ct.
Beaverton, OR 97006
United States
10 Presidential Way
Suite 300
Woburn, MA 01801
United States
Kapittelweg 10
4827 HG Breda
The Nederlands
7140 Baymeadows Way
Ste 101
Jacksonville, FL 32256
United States
2300 So. Decker Lake Blvd.
Salt Lake City, UT 84119
United States
Rue du Clos Courtel
CS 31719
35517 Cesson-Sevigné Cedex
France
1 rue de l’Hautil
Z.I. des Boutries BP 150
78702 Conflans-Sainte
Honorine Cedex
France
Technopole Brest-Iroise
Site de la Pointe du Diable
CS 73808
29238 Brest Cedex 3
France
40 Rue de Bray
2 Rue des Landelles
35510 Cesson Sevigné
France
Spinnereistrasse 5
CH-5300 Turgi
Switzerland
Brunnenweg 9
D-64331 Weiterstadt
Germany
Carl-Benz-Strasse 6-8
67105 Schifferstadt
Germany
Including its implementation, meets the requirements of the standard:
ISO 9001:2008
Scope:
The design, manufacture and support of video and audio hardware and software products and
related systems.
This Certificate is valid until: June 14, 2012
This Certificate is valid as of: June 14, 2009
Certified for the first time: June 14, 2000
H. Pierre Sallé
President
KEMA-Registered Quality
The method of operation for quality certification is defined in the KEMA General Terms
And Conditions For Quality And Environmental Management Systems Certifications.
Integral publication of this certificate is allowed.
KEM
A
-Registered Quality, Inc.
4377 County Line Road
Chalfont, PA 18914
Ph: (215)997-4519
Fax: (215)997-3809
CRT 001 073004
A
ccredited By:
ANAB

K2
Storage
SAN and Direct-Connect
Cabling Guide
071-8713-00
September 2009

4K2 Storage Cabling Guide 03 September 2009
Copyright Copyright © Grass Valley, Inc. All rights reserved. Printed in the United States of America.
Portions of software © 2000 – 2009, Microsoft Corporation. All rights reserved. This document
may not be copied in whole or in part, or otherwise reproduced except as specifically permitted
under U.S. copyright law, without the prior written consent of Grass Valley, Inc., P.O. Box
59900, Nevada City, California 95959-7900. This product may be covered by one or more U.S.
and foreign patents.
Disclaimer Product options and specifications subject to change without notice. The information in this
manual is furnished for informational use only, is subject to change without notice, and should
not be construed as a commitment by Grass Valley, Inc. Grass Valley, Inc. assumes no
responsibility or liability for any errors or inaccuracies that may appear in this publication.
U.S. Government
Restricted Rights
Legend
Use, duplication, or disclosure by the United States Government is subject to restrictions as set
forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause
at DFARS 252.277-7013 or in subparagraph c(1) and (2) of the Commercial Computer
Software Restricted Rights clause at FAR 52.227-19, as applicable. Manufacturer is Grass
Valley, Inc., P.O. Box 59900, Nevada City, California 95959-7900 U.S.A.
Trademarks and
Logos Grass Valley, K2, Aurora, Summit, Dyno, Solo, Infinity, Turbo, M-Series, Profile, Profile XP,
NetCentral, NewsBrowse, NewsEdit, NewsQ, NewsShare, NewsQ Pro, and Media Manager
are either registered trademarks or trademarks of Grass Valley, Inc. in the United States and/
or other countries. Grass Valley, Inc. products are covered by U.S. and foreign patents, issued
and pending. Additional information regarding Grass Valley, Inc. trademarks and other
proprietary rights may be found at www.thomsongrassvalley.com.
Other trademarks and logos used in this document are either registered trademarks or
trademarks of the manufacturers or vendors of the associated products, such as Microsoft®
Windows® operating system, Windows Media® player, Internet Explorer® internet browser,
and SQL Server™. QuickTime and the QuickTime logo are trademarks or registered
trademarks of Apple Computer, Inc., used under license therefrom.
Revision Status
Rev Date Description
03 September
2009 Initial release of the K2 Storage Cabling Guide - 071-8713-00

03 September 2009 K2 Storage Cabling Guide 5
Contents
Chapter 1 Start with the K2 storage system diagram
About custom K2 SANs...........................................................................................7
Level 2 Basic K2 SAN .............................................................................................8
Level 2 Redundant K2 SAN ....................................................................................9
Level 3 Basic K2 SAN .............................................................................................10
Level 3 Redundant K2 SAN ....................................................................................11
Level 10 Basic K2 SAN ...........................................................................................12
Level 10 Redundant K2 SAN ..................................................................................13
Level 20 Basic K2 SAN ...........................................................................................14
Level 20 Redundant K2 SAN ..................................................................................15
Level 30 Basic K2 SAN ...........................................................................................16
Level 30 Redundant K2 SAN ..................................................................................17
Level 35 Basic K2 SAN ...........................................................................................18
Level 35 Redundant K2 SAN ..................................................................................19
Nearline 10 Basic K2 SAN ......................................................................................20
Nearline 10 Redundant K2 SAN..............................................................................21
K2 client with direct-connect storage.......................................................................22
Chapter 2 Cable K2 devices
Cable K2 client ........................................................................................................24
K2 Media Client for basic K2 SAN......................................................................24
K2 Media Client for redundant K2 SAN..............................................................25
K2 Summit Production Client for basic K2 SAN.................................................25
K2 Summit Production Client for redundant K2 SAN .........................................26
K2 Media Client with direct-connect storage......................................................26
K2 Summit Production Client with direct-connect storage..................................27
Cable Gigabit Ethernet switch.................................................................................28
3400cl HP GigE switch for basic K2 SAN...........................................................28
3400cl HP GigE switch for redundant K2 SAN...................................................29
2900 HP GigE switch for basic K2 SAN.............................................................29
2900 HP GigE switch for redundant K2 SAN .....................................................30
2900 HP GigE switch for basic nearline K2 SAN ...............................................30
2900 HP GigE switch for redundant nearline K2 SAN........................................31
Cable K2 Media Server ........................................................................................... 32
Dell 2850 for basic K2 SAN................................................................................33
Dell 2850 for redundant K2 SAN........................................................................33
Dell 1950 GS for Level 10 basic K2 SAN...........................................................34
Dell 1950 GS for Level 10 redundant K2 SAN ...................................................34
Dell 1950 GS for Level 20 basic K2 SAN...........................................................35
Dell 1950 GS for Level 20 redundant K2 SAN ...................................................35
Dell 1950 GS for Level 35 basic K2 SAN...........................................................36
Dell 1950 GS for Level 35 redundant K2 SAN ...................................................37
Dell 2950 for basic K2 SAN................................................................................38
Dell 2950 for redundant K2 SAN........................................................................38
Dell 2950 for Level 3 basic K2 SAN ...................................................................39
Dell 2950 for Level 3 redundant K2 SAN............................................................40
Dell 2950 LS for basic K2 SAN...........................................................................41
Dell 2950 LS for redundant K2 SAN...................................................................41
Dell R610 GS for Level 10 basic K2 SAN...........................................................42
Dell R610 GS for Level 10 redundant K2 SAN...................................................42
Dell R610 GS for Level 20 basic K2 SAN...........................................................42
Dell R610 GS for Level 20 redundant K2 SAN...................................................43
Dell R610 GS for Level 35 basic K2 SAN...........................................................43
Dell R610 GS for Level 35 redundant K2 SAN...................................................44
Dell R710 LS for basic K2 SAN..........................................................................44

6K2 Storage Cabling Guide 03 September 2009
Contents
Dell R710 LS for redundant K2 SAN.................................................................. 45
Cable NH1 K2 Media Server................................................................................... 46
Dell 1950 NH1 for online K2 SAN ...................................................................... 46
Dell 1950 NH1 for basic nearline K2 SAN.......................................................... 46
Dell 1950 NH1 for redundant nearline K2 SAN.................................................. 47
Dell R610 NH1 for online K2 SAN...................................................................... 47
Dell R610 NH1 for basic nearline K2 SAN ......................................................... 47
Dell R610 NH1 for redundant nearline K2 SAN ................................................. 48
Cable NH1-10GE K2 Media Server ........................................................................ 49
Dell 1950 NH1-10GE for online K2 SAN............................................................ 49
Dell 1950 NH1-10GE for basic nearline K2 SAN ............................................... 49
Dell 1950 NH1-10GE for redundant nearline K2 SAN........................................ 50
Dell R610 NH1-10GE for online K2 SAN ........................................................... 50
Dell R610 NH1-10GE for basic nearline K2 SAN............................................... 50
Dell R610 NH1-10GE for redundant nearline K2 SAN....................................... 51
Cable K2 RAID........................................................................................................ 52
K2 RAID for Level 2 basic K2 SAN .................................................................... 53
K2 RAID for Level 2 redundant K2 SAN............................................................. 54
K2 RAID for basic K2 SAN................................................................................. 55
K2 RAID for redundant K2 SAN......................................................................... 56
K2 RAID for Level 10 basic K2 SAN .................................................................. 57
K2 RAID for Level 10 redundant K2 SAN........................................................... 58
K2 RAID for Level 20 basic K2 SAN .................................................................. 59
K2 RAID for Level 20 redundant K2 SAN........................................................... 60
K2 RAID for Level 30 basic K2 SAN .................................................................. 61
K2 RAID for Level 30 redundant K2 SAN........................................................... 62
K2 RAID for Level 35 basic K2 SAN .................................................................. 63
K2 RAID for Level 35 redundant K2 SAN........................................................... 64
K2 RAID for Nearline 10 basic K2 SAN.............................................................. 65
K2 RAID for Nearline 10 redundant K2 SAN...................................................... 66
K2 RAID for K2 client direct-connect storage..................................................... 67
Chapter 3 For more information
K2 Release Notes ................................................................................................... 69
K2 Documentation CD ............................................................................................ 69
On-line Help Systems ............................................................................................. 70
NetCentral documentation ...................................................................................... 70
Grass Valley Web Site ............................................................................................ 70
Using the Dell Server documentation...................................................................... 70
Grass Valley Product Support................................................................................. 72
Telephone Support............................................................................................. 72

03 September 2009 K2 Storage Cabling Guide 7
Chapter 1
Start with the K2 storage system dia-
gram
To follow cabling instructions for your K2™ Storage Area Network (SAN) or
direct-connect storage K2 client, start with the system cabling diagram for your K2
system. Then follow the references below the system diagram to locate cabling
instructions for the individual devices of your K2 system.
Refer to the K2 Storage System Instruction Manual or the K2 SAN Installation and
Configuration Guide for more information on K2 SAN levels and devices. Refer to
the K2 System Guide for more information on direct-connect K2 client storage.
•“Level 2 Basic K2 SAN” on page 8
•“Level 2 Redundant K2 SAN” on page 9
•“Level 3 Basic K2 SAN” on page 10
•“Level 3 Redundant K2 SAN” on page 11
•“Level 10 Basic K2 SAN” on page 12
•“Level 10 Redundant K2 SAN” on page 13
•“Level 20 Basic K2 SAN” on page 14
•“Level 20 Redundant K2 SAN” on page 15
•“Level 30 Basic K2 SAN” on page 16
•“Level 30 Redundant K2 SAN” on page 17
•“Level 35 Basic K2 SAN” on page 18
•“Level 35 Redundant K2 SAN” on page 19
•“Nearline 10 Basic K2 SAN” on page 20
•“Nearline 10 Redundant K2 SAN” on page 21
About custom K2 SANs
Custom systems are those that do not fit one of the pre-defined Level 2, 3, 10, 20, 30,
35, or nearline configurations. For example, a K2 SAN with Fibre Channel attached
K2 clients is considered a custom system. Custom systems that are an extension of
Level 2 or 3 are considered to be Level 4 systems. Custom systems that are an
extension of Level 10, 20, or 30 are considered to be Level 40 systems. Only qualified
Grass Valley personnel should attempt to design, install, and configure custom
systems.
This document and the other documents in the K2 documentation set are intended for
customers with one of the pre-defined SAN levels. While much of the information
also appliesto custom systems,consult yourGrass Valley representative before using
procedures on a custom system.

8K2 Storage Cabling Guide 03 September 2009
Chapter 1 Start with the K2 storage system diagram
Level 2 Basic K2 SAN
This manual documents the default GigE switch configuration. Other configurations are available,
depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System
Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.
To cable this K2 SAN
device… Of this model or
platform… Turn to these instructions:
K2 client K2 Media Client,
including SDA-00,
SD-00, and HD-00.
“K2 Media Client for basic K2 SAN” on page 24
Gigabit Ethernet Switch HP 3400cl series “3400cl HP GigE switch for basic K2 SAN” on page 28
HP 2900 series “2900 HP GigE switch for basic K2 SAN” on page 29
K2 Media Server Dell 2850 “Dell 2850 for basic K2 SAN” on page 33
Dell 2950 “Dell 2950 for basic K2 SAN” on page 38
K2 RAID Level 2 K2 RAID “K2 RAID for Level 2 basic K2 SAN” on page 53
K2 Media Clients
Gigabit Ethernet Switch
FTP
Control
Media
Control
Media
Control
Media
Control
Control
Media
Media
Control point PC
! ! !
L2 RAID Primary
Chassis
L2 RAID Expansion
Chassis(optional)
K2 Media Server
Fibre Channel
connection
POWER SERVICE
K2
RAIDSTORAGE
!
POWER SERVICE
K2
RAIDSTORAGE
!
Control
FTP/streaming

03 September 2009 K2 Storage Cabling Guide 9
Level 2 Redundant K2 SAN
Level 2 Redundant K2 SAN
This manual documents the default GigE switch configuration. Other configurations are available,
depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System
Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.
To cable this K2 SAN
device… Of this model or
platform… Turn to these instructions:
K2 client K2 Media Client,
including SDA-00,
SD-00, and HD-00.
“K2 Media Client for redundant K2 SAN” on page 25
Gigabit Ethernet Switch HP 3400cl series “3400cl HP GigE switch for redundant K2 SAN” on page 29
HP 2900 series “2900 HP GigE switch for redundant K2 SAN” on page 30
K2 Media Server Dell 2850 “Dell 2850 for redundant K2 SAN” on page 33
Dell 2950 “Dell 2950 for redundant K2 SAN” on page 38
K2 RAID Level 2 K2 RAID “K2 RAID for Level 2 redundant K2 SAN” on page 54
L2R RAID Primary
Chassis
L2R RAID Expansion
Chassis(optional)
K2 Media
Servers
AB
AB
K2 Media Clients
Gigabit Ethernet
switches
Fibre Channel
connections
Control B
Media B
Control A
Media A
Control A
Media A
Control B
Media B Control
FTP
Media
Media
Control
Media
Media
FTP
Control point PC
POWER SERVICE
K2
RAIDSTORAGE
!
POWER SERVICE
K2
RAIDSTORAGE
!
! ! !
Control ISLs
Control
FTP/streaming
Control B
Media B
Control A
MediaA

10 K2 Storage Cabling Guide 03 September 2009
Chapter 1 Start with the K2 storage system diagram
Level 3 Basic K2 SAN
This manual documents the default GigE switch configuration. Other configurations are available,
depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System
Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.
To cable this K2 SAN
device… Of this model or
platform… Turn to these instructions:
K2 client K2 Media Client,
including SDA-00,
SD-00, and HD-00.
“K2 Media Client for basic K2 SAN” on page 24
Gigabit Ethernet Switch HP 3400cl series “3400cl HP GigE switch for basic K2 SAN” on page 28
HP 2900 series “2900 HP GigE switch for basic K2 SAN” on page 29
K2 Media Server Dell 2850 “Dell 2850 for basic K2 SAN” on page 33
Dell 2950 “Dell 2950 for Level 3 basic K2 SAN” on page 39
K2 RAID Level 3 K2 RAID “K2 RAID for basic K2 SAN” on page 55
K2 Media Clients
Gigabit Ethernet Switch
FTP
Control
Media
Control
Media
Control
Media
Control
Control
Media
Control
Media
Media
Media
Control point PC
! ! !
L3RAID Primary
Chassis
L3RAID Expansion
Chassis(optional)
K2 Media
Servers
12
Fibre Channel
connections
POWER SERVICE
K2
RAIDSTORAGE
!
POWER SERVICE
K2
RAIDSTORAGE
!
POWER SERVICE
K2
RAIDSTORAGE
!
POWER SERVICE
K2
RAIDSTORAGE
!
Control
FTP/streaming

03 September 2009 K2 Storage Cabling Guide 11
Level 3 Redundant K2 SAN
Level 3 Redundant K2 SAN
This manual documents the default GigE switch configuration. Other configurations are available,
depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System
Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.
To cable this K2 SAN
device… Of this model or
platform… Turn to these instructions:
K2 client K2 Media Client,
including SDA-00,
SD-00, and HD-00.
“K2 Media Client for redundant K2 SAN” on page 25
Gigabit Ethernet Switch HP 3400cl series “3400cl HP GigE switch for redundant K2 SAN” on page 29
HP 2900 series “2900 HP GigE switch for redundant K2 SAN” on page 30
K2 Media Server Dell 2850 “Dell 2850 for redundant K2 SAN” on page 33
Dell 2950 “Dell 2950 for Level 3 redundant K2 SAN” on page 40
K2 RAID Level 3 K2 RAID “K2 RAID for redundant K2 SAN” on page 56
L3R RAID Primary
Chassis
L3R RAID Expansion
Chassis(optional)
K2 Media
Servers
1A
AB
2A 1B 2B
K2 Media Clients
Gigabit Ethernet
Switches
Fibre Channel
connections
Control B
Media B
Control A
Media A
Control A
Media A
Control B
Media B Control
FTP
Media
Media
Control
Media
Media
Control
FTP
Media
Media
Control
Media
Media
Control point PC
POWER SERVICE
K2
RAIDSTORAGE
!
POWER SERVICE
K2
RAIDSTORAGE
!
POWER SERVICE
K2
RAIDSTORAGE
!
POWER SERVICE
K2
RAIDSTORAGE
!
! ! !
Control ISLs
Control
Control
FTP/streaming
Control B
Media B
Control A
MediaA

12 K2 Storage Cabling Guide 03 September 2009
Chapter 1 Start with the K2 storage system diagram
Level 10 Basic K2 SAN
This manual documents the default GigE switch configuration. Other configurations are available,
depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System
Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.
To cable this K2 SAN
device… Of this model or
platform… Turn to these instructions:
K2 client K2 Media Client,
including SDA-00,
SD-00, and HD-00.
“K2 Media Client for basic K2 SAN” on page 24
K2 Summit
Production Client “K2 Summit Production Client for basic K2 SAN” on page 25
Gigabit Ethernet Switch HP 2900 series “2900 HP GigE switch for basic K2 SAN” on page 29
K2 Media Server Dell 1950 “Dell 1950 GS for Level 10 basic K2 SAN” on page 34
Dell R610 “Dell R610 GS for Level 10 basic K2 SAN” on page 42
K2 RAID Level 10 K2 RAID “K2 RAID for Level 10 basic K2 SAN” on page 57
RAID Primary
Chassis
RAID Expansion
Chassis(optional)
K2 Media
Server
K2 clients
Gigabit Ethernet Switch
Control
Media
Control
Media
Control
FTP
Media
Control point PC
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 MEDIA SERVER
Control
Control
FTP/streaming
Control
Media
Fibre
Channel

03 September 2009 K2 Storage Cabling Guide 13
Level 10 Redundant K2 SAN
Level 10 Redundant K2 SAN
This manual documents the default GigE switch configuration. Other configurations are available,
depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System
Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.
To cable this K2 SAN
device… Of this model or
platform… Turn to these instructions:
K2 client K2 Media Client,
including SDA-00,
SD-00, and HD-00.
“K2 Media Client for redundant K2 SAN” on page 25
K2 Summit
Production Client “K2 Summit Production Client for redundant K2 SAN” on
page 26
Gigabit Ethernet Switch HP 2900 series “2900 HP GigE switch for redundant K2 SAN” on page 30
K2 Media Server Dell 1950 “Dell 1950 GS for Level 10 redundant K2 SAN” on page 34
Dell R610 “Dell R610 GS for Level 10 redundant K2 SAN” on page 42
K2 RAID Level 10 K2 RAID “K2 RAID for Level 10 redundant K2 SAN” on page 58
RAID Primary
Chassis
RAID Expansion
Chassis(optional)
K2 Media
Servers
AB
BA
Gigabit Ethernet
Switches
Control B
Media B
Control A
Media A
Control A
Media A
Control B
Media B
Control
FTP
Media
Control
FTP
Media
Control point PC
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
K2 clients
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 MEDIA SERVER K2 MEDIA SERVER
Control ISLs
Control
Control
FTP/streaming
Control B
Media B
Control A
MediaA
Fibre
Channel
Fibre
Channel

14 K2 Storage Cabling Guide 03 September 2009
Chapter 1 Start with the K2 storage system diagram
Level 20 Basic K2 SAN
This manual documents the default GigE switch configuration. Other configurations are available,
depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System
Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.
Multiple NH servers must be of the same type, either all NH1-10GE or all NH1.
To cable this K2 SAN
device… Of this model or
platform… Turn to these instructions:
K2 client K2 Media Client,
including SDA-00,
SD-00, and HD-00.
“K2 Media Client for basic K2 SAN” on page 24
K2 Summit
Production Client “K2 Summit Production Client for basic K2 SAN” on page 25
Gigabit Ethernet Switch HP 2900 series “2900 HP GigE switch for basic K2 SAN” on page 29
K2 Media Server Dell 1950 “Dell 1950 GS for Level 20 basic K2 SAN” on page 35
Dell R610 “Dell R610 GS for Level 20 basic K2 SAN” on page 42
NH1 K2 Media Server
(optional) Dell 1950 “Dell 1950 NH1 for online K2 SAN” on page 46
Dell R610 “Dell R610 NH1 for online K2 SAN” on page 47
NH1-10GE K2 Media
Server (optional) Dell 1950 “Dell 1950 NH1-10GE for online K2 SAN” on page 49
Dell R610 “Dell R610 NH1-10GE for online K2 SAN” on page 50
K2 RAID Level 20 K2 RAID “K2 RAID for Level 20 basic K2 SAN” on page 59
RAID Primary
Chassis
RAID Expansion
Chassis(optional)
K2 Media Server
Gigabit Ethernet Switch
Control
Media
Control
Media
Control
FTP
Media
Media
Control point PC
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
K2 clients
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 MEDIA SERVER
Control
Control
FTP/streaming
Control
Media
Fibre Channel
NH Server
(optional)
K2 MEDIA SERVER
Con
tr
o
l
FT
P

03 September 2009 K2 Storage Cabling Guide 15
Level 20 Redundant K2 SAN
Level 20 Redundant K2 SAN
This manual documents the default GigE switch configuration. Other configurations are available,
depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System
Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.
Multiple NH servers must be of the same type, either all NH1-10GE or all NH1.
To cable this K2 SAN
device… Of this model or
platform… Turn to these instructions:
K2 client K2 Media Client,
including SDA-00,
SD-00, and HD-00.
“K2 Media Client for redundant K2 SAN” on page 25
K2 Summit
Production Client “K2 Summit Production Client for redundant K2 SAN” on
page 26
Gigabit Ethernet Switch HP 2900 series “2900 HP GigE switch for redundant K2 SAN” on page 30
K2 Media Server Dell 1950 “Dell 1950 GS for Level 20 redundant K2 SAN” on page 35
Dell R610 “Dell R610 GS for Level 20 redundant K2 SAN” on page 43
NH1 K2 Media Server
(optional) Dell 1950 “Dell 1950 NH1 for online K2 SAN” on page 46
Dell R610 “Dell R610 NH1 for online K2 SAN” on page 47
NH1-10GE K2 Media
Server (optional) Dell 1950 “Dell 1950 NH1-10GE for online K2 SAN” on page 49
Dell R610 “Dell R610 NH1-10GE for online K2 SAN” on page 50
K2 RAID Level 20 K2 RAID “K2 RAID for Level 20 redundant K2 SAN” on page 60
RAID Primary
Chassis
RAID Expansion
Chassis(optional)
K2 Media
Servers
NH Servers
(optional)
AB
BA
Gigabit Ethernet
Switches
Fibre Channel
Control B
Media B
Control A
Media A
Control A
Media A
Control B
Media B
Control
FTP
Media
Media
Control
FTP
Media
Media
Control point PC
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
K2 clients
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 MEDIA SERVER K2 MEDIA SERVER
K2 MEDIA SERVER
Control ISLs
Control
Control
FTP/streaming
Control B
Media B
Control A
MediaA
MEDIA SERVER
Fibre Channel
Control
FTP
Contro
l
FTP

16 K2 Storage Cabling Guide 03 September 2009
Chapter 1 Start with the K2 storage system diagram
Level 30 Basic K2 SAN
This manual documents the default GigE switch configuration. Other configurations are available,
depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System
Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.
Multiple NH servers must be of the same type, either all NH1-10GE or all NH1.
To cable this K2 SAN
device… Of this model or
platform… Turn to these instructions:
K2 client K2 Media Client,
including SDA-00,
SD-00, and HD-00.
“K2 Media Client for basic K2 SAN” on page 24
K2 Summit
Production Client “K2 Summit Production Client for basic K2 SAN” on page 25
Gigabit Ethernet Switch HP 2900 series “2900 HP GigE switch for basic K2 SAN” on page 29
K2 Media Server Dell 2950 “Dell 2950 LS for basic K2 SAN” on page 41
Dell R710 “Dell R710 LS for basic K2 SAN” on page 44
NH1 K2 Media Server
(optional) Dell 1950 “Dell 1950 NH1 for online K2 SAN” on page 46
Dell R610 “Dell R610 NH1 for online K2 SAN” on page 47
NH1-10GE K2 Media
Server (optional) Dell 1950 “Dell 1950 NH1-10GE for online K2 SAN” on page 49
Dell R610 “Dell R610 NH1-10GE for online K2 SAN” on page 50
K2 RAID Level 30 K2 RAID “K2 RAID for Level 30 basic K2 SAN” on page 61
RAID Primary
Chassis
RAID Expansion
Chassis(optional)
K2 Media Server
Gigabit Ethernet Switch
Control
Media
Control
Media
Control
FTP
Media
Media
Media
Media
Control point PC
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
K2 clients
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 MEDIA SERVER
Control
Control
FTP/streaming
Control
Media
Fibre Channel
NH Server
(optional)
K2 MEDIA SERVER
Con
tr
o
l
FT
P

03 September 2009 K2 Storage Cabling Guide 17
Level 30 Redundant K2 SAN
Level 30 Redundant K2 SAN
This manual documents the default GigE switch configuration. Other configurations are available,
depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System
Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.
Multiple NH servers must be of the same type, either all NH1-10GE or all NH1.
To cable this K2 SAN
device… Of this model or
platform… Turn to these instructions:
K2 client K2 Media Client,
including SDA-00,
SD-00, and HD-00.
“K2 Media Client for redundant K2 SAN” on page 25
K2 Summit
Production Client “K2 Summit Production Client for redundant K2 SAN” on
page 26
Gigabit Ethernet Switch HP 2900 series “2900 HP GigE switch for redundant K2 SAN” on page 30
K2 Media Server Dell 2950 “Dell 2950 LS for redundant K2 SAN” on page 41
Dell R710 “Dell R710 LS for redundant K2 SAN” on page 45
NH1 K2 Media Server
(optional) Dell 1950 “Dell 1950 NH1 for online K2 SAN” on page 46
Dell R610 “Dell R610 NH1 for online K2 SAN” on page 47
NH1-10GE K2 Media
Server (optional) Dell 1950 “Dell 1950 NH1-10GE for online K2 SAN” on page 49
Dell R610 “Dell R610 NH1-10GE for online K2 SAN” on page 50
K2 RAID Level 30 K2 RAID “K2 RAID for Level 30 redundant K2 SAN” on page 62
RAID Primary
Chassis
RAID Expansion
Chassis(optional)
K2 Media
Servers
NH Servers
(optional)
AB
BA
Gigabit Ethernet
Switches
Fibre Channel
Control B
Media B
Control A
Media A
Control A
Media A
Control B
Media B
Control
FTP
Media
Media
Media
Media
Control
FTP
Media
Media
Media
Media
Control point PC
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
K2 clients
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 MEDIA SERVER K2 MEDIA SERVER
K2 MEDIA SERVER
Control ISLs
Control
Control
FTP/streaming
Control B
Media B
Control A
MediaA
MEDIA SERVER
Fibre Channel
Control
FTP
Contro
l
FTP

18 K2 Storage Cabling Guide 03 September 2009
Chapter 1 Start with the K2 storage system diagram
Level 35 Basic K2 SAN
This manual documents the default GigE switch configuration. Other configurations are available,
depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System
Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.
To cable this K2 SAN
device… Of this model or
platform… Turn to these instructions:
K2 client K2 Media Client,
including SDA-00,
SD-00, and HD-00.
“K2 Media Client for basic K2 SAN” on page 24
K2 Summit
Production Client “K2 Summit Production Client for basic K2 SAN” on page 25
Gigabit Ethernet Switch HP 2900 series “2900 HP GigE switch for basic K2 SAN” on page 29
K2 Media Server Dell 1950 “Dell 1950 GS for Level 35 basic K2 SAN” on page 36
Dell R610 “Dell R610 GS for Level 35 basic K2 SAN” on page 43
NH1-10GE K2 Media
Server (optional) Dell 1950 “Dell 1950 NH1-10GE for online K2 SAN” on page 49
Dell R610 “Dell R610 NH1-10GE for online K2 SAN” on page 50
K2 RAID Level 35 K2 RAID “K2 RAID for Level 35 basic K2 SAN” on page 63
L30 RAID Primary
Chassis
RAID Expansion
Chassis(optional)
GSK2 Media Servers
21
Gigabit Ethernet Switch
Control
Media
Control
Media
Control
Media
Media
Control point PC
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
K2 clients
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 MEDIA SERVER
Control
FTP
Media
Media
K2 MEDIA SERVER
Control
Control
FTP/streaming
Control
Media
Fibre Channel
NH1-10GE
Server
(optional)
K2 MEDIA SERVER
Con
tr
o
l
FTP

03 September 2009 K2 Storage Cabling Guide 19
Level 35 Redundant K2 SAN
Level 35 Redundant K2 SAN
This manual documents the default GigE switch configuration. Other configurations are available,
depending on your port count and FTP bandwidth requirements. Refer to the K2 Storage System
Instruction Manual or the K2 SAN Installation and Configuration Guide for more information.
To cable this K2 SAN
device… Of this model or
platform… Turn to these instructions:
K2 client K2 Media Client,
including SDA-00,
SD-00, and HD-00.
“K2 Media Client for redundant K2 SAN” on page 25
K2 Summit
Production Client “K2 Summit Production Client for redundant K2 SAN” on
page 26
Gigabit Ethernet Switch HP 2900 series “2900 HP GigE switch for redundant K2 SAN” on page 30
K2 Media Server Dell 1950 “Dell 1950 GS for Level 35 redundant K2 SAN” on page 37
Dell R610 “Dell R610 GS for Level 35 redundant K2 SAN” on page 44
NH1-10GE K2 Media
Server (optional) Dell 1950 “Dell 1950 NH1-10GE for online K2 SAN” on page 49
Dell R610 “Dell R610 NH1-10GE for online K2 SAN” on page 50
K2 RAID Level 35 K2 RAID “K2 RAID for Level 35 redundant K2 SAN” on page 64
NH1-10GE
Server (optional)
K2 MEDIA SERVER
Con
tr
o
l
FTP
Fibre Channel Fibre Channel
L30 RAID Primary
Chassis
RAID Expansion
Chassis(optional)
1A
AB
2A 1B 2B
Gigabit Ethernet Switches
Control A
MediaA
Control A
Control B
MediaA
MediaB
Control B
MediaB
Control
FTP
Media
Media
Control
Media
Media
Control
FTP
Media
Media
Control
Media
Media
Control point PC
!K2 SAS STORAGE
K2 clients
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 SUMMIT
PRODUCTIONCLIENT
K2 MEDIA SERVER K2 MEDIASERVER K2 MEDIA SERVER K2 MEDIA SERVER
Control ISLs
Control
Control
FTP/streaming
Control B
MediaB
Control A
MediaA
!K2 SAS STORAGE
!K2 SAS STORAGE
!K2 SAS STORAGE
GSK2 Media
Servers

20 K2 Storage Cabling Guide 03 September 2009
Chapter 1 Start with the K2 storage system diagram
Nearline 10 Basic K2 SAN
To cable this K2 SAN
device… Of this model or
platform… Turn to these instructions:
Gigabit Ethernet Switch HP 2900 series “2900 HP GigE switch for basic nearline K2 SAN” on
page 30
NH1 K2 Media Server Dell 1950 “Dell 1950 NH1 for basic nearline K2 SAN” on page 46
Dell R610 “Dell R610 NH1 for basic nearline K2 SAN” on page 47
NH1-10GE K2 Media
Server Dell 1950 “Dell 1950 NH1-10GE for basic nearline K2 SAN” on
page 49
Dell R610 “Dell R610 NH1-10GE for basic nearline K2 SAN” on
page 50
K2 RAID Level 10 K2 RAID “K2 RAID for Nearline 10 basic K2 SAN” on page 65
Control
RAID Chassis
(SATA drives)
RAID Expansion Chassis
(SATA drives)
NH K2 Media
Server
Gigabit Ethernet
Switch
Fibre Channel
connection
Control
FTP
Control point PC
!K2 SATA STORAGE
!K2 SATA STORAGE
!K2 SATA STORAGE
!K2 SATA STORAGE
K2 MEDIA SERVER
Control
FTP to/from online system
Other manuals for K2 BASECAMP EXPRESS
20
Table of contents
Other GRASS VALLEY Storage manuals

GRASS VALLEY
GRASS VALLEY PFR 600/E User manual

GRASS VALLEY
GRASS VALLEY K2 BASECAMP EXPRESS User manual

GRASS VALLEY
GRASS VALLEY K2 BASECAMP EXPRESS User manual

GRASS VALLEY
GRASS VALLEY K2 Lx0 User manual

GRASS VALLEY
GRASS VALLEY PROFILE XP PFR 500 User manual

GRASS VALLEY
GRASS VALLEY K2 BASECAMP EXPRESS User manual

GRASS VALLEY
GRASS VALLEY K2 BASECAMP EXPRESS Manual

GRASS VALLEY
GRASS VALLEY REV PRO Quick start guide

GRASS VALLEY
GRASS VALLEY Profile XP PFR500/E User manual

GRASS VALLEY
GRASS VALLEY K2 BASECAMP EXPRESS User manual