Green Brook DH020A User manual

INSTRUCTIONS FOR WIRED
DOORCHIMES & PUSHES
MODEL NUMBERS -
Doorc imes -
DH020A: Galaxy C ime
DH021A: Tubular C ime
DH022A: Moon C ime
DH050A: Galaxy C ime Kit
Bell Pus es -
If you have bought a be push on y
p ease go straight to STEP 3a. in these
instructions.
DP010A: Black Bell Pus
DP020A: W ite Bell Pus
DP050A: Brass Plate Bell Pus
DP060A: Brass Bell (wit name card)
DP070A: Brass Surface Mount Bell
DP080A: Brass Bell Pus
DP090A: Brass Round Bell Pus
DP100A: Antique Copper Bell
DP110A: Wroug t Iron Black Bell
DPL12A: ‘Pus A Lite’ Brass Pus
DPL13A: ‘Pus A Lite’ Silver Button
(for DPL12A & DPL13A p ease a so
note step 3b)
DPL03A: Lit (illuminated) Black Bell
DPL04A: Lit (illuminated) W ite Bell
(DPL03A & DPL04A must be used with a
be transformer)
This doorchime has a traditional
ding-dong sound and is easily
fitted for use with any door push.
• Bell wire required (included
in DH050A Galaxy Chime Kit)
• Bell push required (included
in DH050A Galaxy Chime Kit).
An ornate door push can be
used if preferred. (For lit bell
pushes a transformer must
also be used - GreenBrook
Model Number ‘DAT01A’)
• Fixing screws included
• Requires 3 x C cell R14
batteries (not included)
PLEASE READ THE FOLLOWING
INSTRUCTIONS FULLY BEFORE
ATTEMPTING INSTALLATION.
1) Using a knife, carefully split
the bell wire down the
middle to form two separate
wires, each 30mm long.
2) Strip each wire back to expose
5mm of copper wire.
STEP 1.
PREPARING BELL WIRE
STEP 2. WIRING
YOUR DOORCHIME
STEP 3a. WIRING
YOUR BELL PUSH
3) The process will
need to be
repeated at the
other end of
the bell wire once
it has been cut to
the required length.
4) The bell wire is now ready to
wire up the doorchime to the
bell push.
1) Unclip top cover.
2) Thread bell wire from the
back of the base and through
the large opening to the left
of the keyhole slot.
3) Insert either one of the
stripped ends to terminal A
and the other to terminal C,
ensuring the terminal screws
are tightened securely after-
wards. Do not use terminals
marked B and D.
4) Position the base on the wall
vertically, away from opening
doors, with the battery
compartment at the bottom.
Ensure that it is less than 5
metres away from the bell
push.
5) Use one of the screws and
wall fixings to hang the base
on the wall via the top key
hole slot. Adjust the screw for
a flush fit if required.
6) Insert 3 x C cell batteries as
per markings on the inside of
the case.
1) If necessary, remove the base
cover of the bell push to
reveal the terminal screws.
2) Loosen one of
the terminal screws
and wrap one of
the stripped ends
of bell wire around
the exposed screw
thread, ensuring
Issue No: 701336
West Road,
Harlow,
Essex
CM20 2BG
Tel 01279 772 750
Fax 01279 635 2 5
Email: [email protected]
Web: www.greenbrook.co.uk
GUARANTEE
TROUBLE SHOOTING
STEP 3b.
PUSH A LITE BUTTONS
(DPL12 & DPL13 ONLY)
STEP 4.
USING A TRANSFORMER
the screw is tightened securely
afterwards. Repeat this process
for the other screw terminal
and wire.
3) Fix the base to the doorframe
using two of the screws and
ll fixings provided. Try to
position the door push in an
unexposed place to protect it
from bad weather.
4) Snap the cover back on if
appropriate.
An alternative bell push can be
used with this doorchime, please
follow the instructions on the
pack.
Certain door push models can be
converted to illuminated pushes
by purchasing either a
GreenBrook DPL12A or DPL13A
bell push button separately. Please
note:For illuminated pushes, a bell
transformer must be used.
GreenBrook models - DP050A,
DP060A, DP0 0A, DP100 and
DP110 are all suitable to convert
to illuminated pushes.
Simply press the button on the
back through the front panel of
the door push and swap it with
the ‘Push A Lite’ button. Wire up
a bell transformer following Step 4.
For use with an i uminated be
push.
Only an Volt 1Amp transformer
is recommended, (Greenbrook
Model DAT01A). Please carefully
follow the manufacturer’s
instructions - use terminals C and
D on the doorchime case to
connect up the transformer.
Remove the batteries from the
doorchime and ensure the power
is switched off at the mains
before attempting any wiring.
If the doorchime does not work,
check the batteries and also that
the bell wire is connected to the
correct terminals. Do not use
terminal marked B.
Your Doorchime is guaranteed for
12 months from the date of
purchase. Please retain your till
receipt as proof of purchase. This
is in addition to your statutory
rights.
PLEASE KEEP THESE
INSTRUCTIONS SAFE FOR
FUTURE REFERENCE
If after going through the trouble
shooting section, you still
experience difficulty please ring
us on -
GreenBrook’s He p Line
01279 772 750
during office hours
quoting the model number.

This manual suits for next models

3

Other Green Brook Accessories manuals

Green Brook DHT01A-C User manual

Green Brook

Green Brook DHT01A-C User manual

Green Brook Power Breaker ProteKt User manual

Green Brook

Green Brook Power Breaker ProteKt User manual

Green Brook DC010A Manual

Green Brook

Green Brook DC010A Manual

Green Brook DB285B User manual

Green Brook

Green Brook DB285B User manual

Green Brook KingShield Orion Range User manual

Green Brook

Green Brook KingShield Orion Range User manual

Green Brook DW040A User manual

Green Brook

Green Brook DW040A User manual

Green Brook PowerBreaker K21S-WP Manual

Green Brook

Green Brook PowerBreaker K21S-WP Manual

Green Brook PowerBreaker Protekt PSKTRCDP2G User manual

Green Brook

Green Brook PowerBreaker Protekt PSKTRCDP2G User manual

Green Brook DH020A-C User manual

Green Brook

Green Brook DH020A-C User manual

Green Brook P17 User manual

Green Brook

Green Brook P17 User manual

Green Brook DW050AH User manual

Green Brook

Green Brook DW050AH User manual

Green Brook DW080A-C User manual

Green Brook

Green Brook DW080A-C User manual

Green Brook DH020A User manual

Green Brook

Green Brook DH020A User manual

Green Brook DW060AN-C User manual

Green Brook

Green Brook DW060AN-C User manual

Green Brook M22W User manual

Green Brook

Green Brook M22W User manual

Green Brook DW081A-C User manual

Green Brook

Green Brook DW081A-C User manual

Green Brook SHAS Manual

Green Brook

Green Brook SHAS Manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.