Growatt MIN 2500TL-X User manual

Other manuals for MIN 2500TL-X

2

This manual suits for next models

6

Other Growatt Inverter manuals

Growatt Growatt 2500MTL-S User manual

Growatt

Growatt Growatt 2500MTL-S User manual

Growatt SPF 5000 ES User manual

Growatt

Growatt SPF 5000 ES User manual

Growatt MIN 2500TL-X User manual

Growatt

Growatt MIN 2500TL-X User manual

Growatt SPF 4000T DVM User manual

Growatt

Growatt SPF 4000T DVM User manual

Growatt MID 33-50KTL3-X2 User manual

Growatt

Growatt MID 33-50KTL3-X2 User manual

Growatt Shine WebBox User manual

Growatt

Growatt Shine WebBox User manual

Growatt MIN 2500TL-XH User manual

Growatt

Growatt MIN 2500TL-XH User manual

Growatt 10000HYP User manual

Growatt

Growatt 10000HYP User manual

Growatt 30000 TL3 User manual

Growatt

Growatt 30000 TL3 User manual

Growatt MOD TL3-XH Series User manual

Growatt

Growatt MOD TL3-XH Series User manual

Growatt SPF 4KT HVM User manual

Growatt

Growatt SPF 4KT HVM User manual

Growatt WIT 50-100K-HU User manual

Growatt

Growatt WIT 50-100K-HU User manual

Growatt SPF 5000TL User manual

Growatt

Growatt SPF 5000TL User manual

Growatt MOD 4000TL3-X User manual

Growatt

Growatt MOD 4000TL3-X User manual

Growatt MAX 175KTL3-X HV User manual

Growatt

Growatt MAX 175KTL3-X HV User manual

Growatt 8000TL3-S User manual

Growatt

Growatt 8000TL3-S User manual

Growatt SPF 3500 ES User manual

Growatt

Growatt SPF 3500 ES User manual

Growatt MID 17-40KTL3-X User manual

Growatt

Growatt MID 17-40KTL3-X User manual

Growatt MID 17-33KTL3-X User manual

Growatt

Growatt MID 17-33KTL3-X User manual

Growatt 1500-US User manual

Growatt

Growatt 1500-US User manual

Growatt MTL-S User manual

Growatt

Growatt MTL-S User manual

Growatt Growatt 4200 MTL User manual

Growatt

Growatt Growatt 4200 MTL User manual

Growatt WIT 50-100K-AU User manual

Growatt

Growatt WIT 50-100K-AU User manual

Growatt SPF 3000TL User manual

Growatt

Growatt SPF 3000TL User manual

Popular Inverter manuals by other brands

Omnik New Energy Omniksol-1.5k-TL user manual

Omnik New Energy

Omnik New Energy Omniksol-1.5k-TL user manual

Agilent Technologies 33250A user guide

Agilent Technologies

Agilent Technologies 33250A user guide

4-noks ZR-SWITCH-RC instruction manual

4-noks

4-noks ZR-SWITCH-RC instruction manual

V&T V5 Series user manual

V&T

V&T V5 Series user manual

Hon Turing HT-T-S1000-12 introduction

Hon Turing

Hon Turing HT-T-S1000-12 introduction

Metabo E 140 SP Plus Original operating instructions

Metabo

Metabo E 140 SP Plus Original operating instructions

BARRON EXITRONIX Tucson Micro Series installation instructions

BARRON

BARRON EXITRONIX Tucson Micro Series installation instructions

Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

Baumer

Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

electroil

electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

Silicon Solar TPS555-1230 instruction manual

Silicon Solar

Silicon Solar TPS555-1230 instruction manual

Mission Critical Xantrex Freedom SW-RVC owner's guide

Mission Critical

Mission Critical Xantrex Freedom SW-RVC owner's guide

HP 3312A Operating and service manual

HP

HP 3312A Operating and service manual

Hoymiles HM-500T user manual

Hoymiles

Hoymiles HM-500T user manual

Nitecore SPM10 user manual

Nitecore

Nitecore SPM10 user manual

AEG Protect PV installation manual

AEG

AEG Protect PV installation manual

On Board TruePower Plus 1200MS owner's manual

On Board

On Board TruePower Plus 1200MS owner's manual

Plugreen PGM-200P-230 Installation and operation manual

Plugreen

Plugreen PGM-200P-230 Installation and operation manual

Fourgroup Easy use and Programming Handbook

Fourgroup

Fourgroup Easy use and Programming Handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1 2 3 4567811 12
10
9
MIN 2500-6000TL-X Quick Guide
8-10mm
123
45
2.3 Communication module installation
Inverter side
Inverter side Inverter side
Inverter side
▲Up
UninstallInstall
3.
Electrical connection
Please prepare the cable before connecting as follows.
1
2
3
4
Cable name
PV input wire
Type
Two or three polychromatic
multi-core copper wires
PV wire(such as PV1-F)
RS485
Recommend model
6mm²
6mm²
4mm² - 6mm²
4mm² - 6mm²
4mm² - 6mm²
/
No.
Communication
wire
AC output wire
grounding wire
Protective Single multi-core
yellow-green wire 1.Please make sure all switches are in “OFF”
position before wiring. For personal safety,
please do not operate with electricity.
2.If the diameter of the cable does not match
the terminal, or the cable is aluminum wire,
please contact our after-sales personnel.
Note:
3.1 Grounding 3.2 AC output connection
3.3 DC connection
3.3.1 PV input terminal installation
Positive metal terminal
Positive metal terminal
Negative metal terminal
Negative metal terminal
Negative metal terminal
Please make sure the cable can not be
pulled out after pressing.
Pull the PV cable make sure there
is no loos or shaking.
Make sure the cable polarity is
correct and voltage is less than
550V.
System overview 2.1 Installation requirements
2.2 Wall mounting
Note:
1.When drilling holes in the wall, avoid water and electricity pipes, otherwise it may cause danger.
1.
2.
(1)Front panel (2)Touch button (3)OLED screen (4)LED indicator
(10)DRM port
(5)Heat sink
(6)DC switch (8)PV terminal
(11)RS485 port
(9)USB port
(7)Vent valve
(12)AC terminal
1.This document is for quick installation guidance only, please refer to User Manual for more details.
2.Growatt shall not be liable for any damage resulting from unproper installation.
Note:
Overview
Installation
≥300mm
≥300mm
≥300mm
≥500mm
≥300mm
250
18
Type 1
Type 2
Type 3
179
161
429
375
319 28
350
137.5
GR-UM-149-A-03GR-UM-149-A-03
PV+
PV-
12
Customer can read more information by push button.
Mark
Describe
Explain
Touch mark
Single touch
Switch the display interface or the
current number plus 1
Double touch
Enter the setting state or confirm
Triple touch
Return to the previous display interface
Long press for 5s
Confirm Country setting or Number
recover default value
Inverter status indicator
Red
Fault
Green
Normal operation
Red light flashing
Warning
It can display the basic information of inverter through OLED display screen
(PV/AC voltage,PV power,ACcurrent,total power,generating capacity, etc.).
Shenzhen Growatt New Energy Technology CO.,LTD
No.28 Guangming Road, Shiyan Street, Bao’an District,
Shenzhen, P.R.China
T
E service@ginverter.com
W
9.
8.
Note:
1.Before installing the PV terminal, please
double-check that the PV input voltage and
current do not exceed the MPPT limits.
2.When installing the PV terminal, pay
attention to the difference between the
positive and negative poles and the one-to-
one correspondence between the terminals
and the machine.
3.There is a "click" sound when the terminal
is connected,please gently pulling the PV
wire to make sure there is no loose or
pulling off.
3.3.3 Communication cable installation
Click
Download
Manual Growatt New Energy
3.3.2 Plug in PV terminal
Note:
The Inverter
side
The Inverter
side
Unclock the housing
Click!
Click!
NO.
1
2
3
NO
4
5
6
REFGEN
COM/DRM0
DRM Port Pin Definitions
SYS COM Port Pin Definitions
DRM5
Definition
Definition
No. Definition
1
2
3
4
+12V
COM
RS 485A1
RS 485B1
Power
supply for
external
relay(≤2W)
Signal for
communic
ation
DRM8
DRM7
DRM6
No. Definition
6
5
7
8
RS 485A2
RS 485B2
CT-P
CT-N
Signal for
export
limitation
(Optional)
Signal for
Smart
Meter
1.When laying out signal cables, separate them from power cables to avoid strong signal interference sources
2.Do not mix the connector to the DRM COM port and the connector to the SYS port.
Connecting Meter
4.
The following table describes how we can connect EASTRON meter (SDM230-Modbus)to inverter:
The following table describes how we can connect CHINT meter (DDSU666) to inverter:
Meter Pin NO. Description Meter Connection
1
2
3
4
7
8
L-in
L-out
N-in
N-out
RS485A
RS485B
Grid L
AC connector & Load L
Grid N
AC connector & Load N
SYS COM Pin 7 RS485A2
SYS COM Pin 8 RS485B2
Meter Pin NO. Description Meter Connection
1
2
3
4
5
6
L-in
L-out
N-in
N-out
RS485A
RS485B
Grid L
AC connector & Load L
Grid N
AC connector & Load N
SYS COM Pin 7 RS485A2
SYS COM Pin 8 RS485B2
Note: For Australian market,installers can connect pin3 or
pin4 to the neutral links/bars.
Before turning the inverter on, please make sure the PV input voltage and current are within the MPPT limits.
Follow the steps below to turn the inverter on:
1.Switch on the build-in DC isolator at the bottom of the inverter.
2.Switch on the PV Array and DC isolator next to your inverter, if you can not find this switch, skip this step.
3.Switch on the Solar AC isolator if the inverter is more than 3 meters away from your switchboard.
4.Switch on the solar supply main switch in the switch board.
To shut down your system, follow this guide in reverse order
Note:
6.
Power on and off steps
5.
Post-installation check
No.
Acceptance criteria
No.
Acceptance criteria
1
The inverter is installed correctly, firmly and reliably.
6
The RS485 communication cable is installed correctly and firmly.
2
The ground wire connected well and the connection is firm
and reliable.
7
The cable tie port is trimmed well without leaving sharp
corners,meets the requirements of the user.
3
All switches are in the OFF state.
8
All exposed terminals are well protected and there are no vacant
ports.
4
All wiring is correct and securely connected.
9
Pay attention to clean up all construction residues.
5
The wiring of the cable is reasonable, meets the
requirements, and there is no phenomenon of broken skin.
+86 0755 2747 1942
www.ginverter.com
7. Status of PV grid inverter
Service and contact
Export limitation setting
Exporlimit
OFF ON
Password
123
Set parameter
General
Advanced
Meter
CT
ExportLimit Rate
XXX.X%
Set OK
Under the permission given by your energy
provider, the ratio of your system output
power divided by the rated power of the
inverter is called Export Limit Rate. For
instance, if the energy provider only
accepts 4kW from your 5KW system, then
the Export Limit Rate of 5kW inverter is
80.0%.
1
1
1