© 2017 United Technologies Corporation 1 / 2 P/N 30310840-EN • REV 001 • ISS 27MAR17
DC-M9415 Series Wall Mount
Strobe Installation Sheet
Description
The DC-M9415 Series Wall Mount Strobe is a visible fire alarm
notification appliance that is designed for mounting on indoor walls.
See Table 1 for a list of model numbers.
Table
1: Models
Description
Model number
Strobe, white
DC-M9415W
Strobe, red
DC-M9415R
The strobe includes a field-configurable switch for selecting the desired
candela output and a field-configurable jumper for the strobe signal
output. The candela output setting is locked in place and remains
visible after final installation.
This strobe features an enhanced synchronization circuit to comply
with the latest requirements of UL 1971 Signaling Devices for the
Hearing Impaired.
Synchronized operation requires that you connect the DC-M9415
Series Wall Mount Strobe to a NAC output set for Synch Mode, or to a
separate DC-M9410 Signal Synchronization Module.
Installation
Install and wire this device in accordance with applicable national and
local codes, ordinances, and regulations.
WARNING: Electrocution hazard. To avoid personal injury or death
from electrocution, remove all sources of power and allow 10 minutes
for stored energy to discharge before installing or removing equipment.
Caution: Electrical supervision requires breaking the wire run at each
terminal. Do not loop the signaling circuit field wires around the
terminals.
To install the strobe:
1. Remove the cover by depressing both tabs on the top of the unit
with a small screwdriver and twisting slightly.
2. Slide the candela switch to the desired candela output (15, 30, 75,
or 110 cd) by aligning it with the indicator located beside the
switch. See Figure 1.
3. Set the strobe signal if required. See Figure 2.
4. Connect the strobe terminals to the signal circuit field wiring. You
must observe polarity for the unit to function properly. See
Figure 3.
5. Mount the unit onto a compatible electrical box, making sure not to
over-tighten the mounting screws.
6. Replace the cover by aligning at the bottom, then snapping in at
the top.
7. Test the unit for proper operation.
Figure 1: Candela switch
Figure 2: Strobe signal setting
(1) To change the strobe to temporal (private mode), cut from circle J1
to the edge of circuit board.
Note: If the strobe is set to temporal (private mode), this device is no
longer UL 1971 listed, but is UL 1638 listed.
Figure 3: Wiring diagram
(1) From NAC output
(2) To next appliance, EOLR, or return to source
Note: Polarity is shown in the alarm condition.
110
75
30
15
J2 J3
J1
(1)
(1) (2)
2 / 2 P/N 30310840-EN • REV 001 • ISS 27MAR17
Maintenance
Caution: To maintain the required agency listings, do not change
factory applied finishes.
This unit is not serviceable or repairable. Should the unit fail to
operate, contact the supplier for replacement.
Perform a visual inspection and an operational test twice a year or as
directed by the local authority having jurisdiction.
Specifications
Operating
voltage 24 VDC or 24 VFWR nominal
Strobe operating
current See Table 2
Light output
Selectable at 15, 30, 75, and 110 cd
Synchronization
Meets UL 1971 requirements. Maximum
allowed resistance between any two devices
is 20 Ω. Refer to specifications for the
synchronization control module, this strobe,
and the control panel to determine allowed
wire resistance.
Strobe signal rate
1 flash per second (fps)
Wire size
12 to 18 AWG (0.75 to 2.50 mm²)
Compatible electrical
boxes
Single-gang box, 2-1/2 in. (64 mm) deep
Operating environment
Temperature
Relative humidity
32 to 120°F (0 to 49°C)
0 to 93% noncondensing
Table
2: Strobe operating current in RMS (A)
15 cd 30 cd 75 cd 110 cd
16 Vdc
0.103 0.141 0.255 0.311
16 Vfwr
0.125 0.179 0.346 0.392
VDC
= Volts direct current, regulated and filtered
VFWR = Volts full wave rectified
Figure 4: UL 1971 minimum light output (% of rating vs. angle)
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
0510 15 20 25 30 35 40 4550556065
70
75
80
85
90
-5
-10
-15
-20
-25
-30
-35
-40
-45
-50
-55
-60
-65
-70
-75
-80
-85
-90
Angle
Percentage of rated output
Horizontal and vertical outputs reflect the same pattern.
Regulatory information
UL
rating Regulated 24 VDC and 24 VFWR
Environmental
class
UL: Indoor, Dry
North American
standards
UL 1638 and UL 1971
Contact information
For information or questions, please contact:
Gulf Security Technology Co., Ltd.
No. 80, Changjiang East Road,
QETDZ, Qinhuangdao, Hebei, P. R. China 066004
Tel +86 (0) 335 8502434
Fax +86 (0) 335 8502532
[email protected]
www.gst.com.cn

This manual suits for next models

2

Other GST Fire Alarm manuals

GST I-9202 User manual

GST

GST I-9202 User manual

GST DC-9102E User manual

GST

GST DC-9102E User manual

GST DI-9204Exd User manual

GST

GST DI-9204Exd User manual

GST DC-9204E User manual

GST

GST DC-9204E User manual

GST DI-9204 User manual

GST

GST DI-9204 User manual

GST GST-IFP8 User manual

GST

GST GST-IFP8 User manual

GST GST-MNA2C User manual

GST

GST GST-MNA2C User manual

GST DI-9406 User manual

GST

GST DI-9406 User manual

GST DI-9204 User manual

GST

GST DI-9204 User manual

GST C-9401 User manual

GST

GST C-9401 User manual

Popular Fire Alarm manuals by other brands

Plymovent Shield 5k1 Installation and user manual

Plymovent

Plymovent Shield 5k1 Installation and user manual

Wheelock MB Series installation instructions

Wheelock

Wheelock MB Series installation instructions

Brooks RFS1 V2 Operation & installation manual

Brooks

Brooks RFS1 V2 Operation & installation manual

Ziton ZP1-F2 installation manual

Ziton

Ziton ZP1-F2 installation manual

FireClass MCP200CS quick start guide

FireClass

FireClass MCP200CS quick start guide

FIREWOLF FW-C01224 owner's manual

FIREWOLF

FIREWOLF FW-C01224 owner's manual

Tyco RC-1 manual

Tyco

Tyco RC-1 manual

Zeta Alarm Systems Premier Quatro QT/1 installation manual

Zeta Alarm Systems

Zeta Alarm Systems Premier Quatro QT/1 installation manual

E2S D2xB1LD3 instruction manual

E2S

E2S D2xB1LD3 instruction manual

FireClass DUO-CEL Application guide

FireClass

FireClass DUO-CEL Application guide

Harrington Network Plus HS-3030 Programming manual

Harrington

Harrington Network Plus HS-3030 Programming manual

Tanda TX7320 Installation and operation manual

Tanda

Tanda TX7320 Installation and operation manual

Plumis Automist User handbook manual

Plumis

Plumis Automist User handbook manual

Sargent 2900 Series FIREGUARD Wiring instructions

Sargent

Sargent 2900 Series FIREGUARD Wiring instructions

Siemens SFPO-11 Installation instructions manual

Siemens

Siemens SFPO-11 Installation instructions manual

Mircom FX-350 Series user guide

Mircom

Mircom FX-350 Series user guide

LEGRAND 380 42 quick start guide

LEGRAND

LEGRAND 380 42 quick start guide

RUBETEK CP-1 manual

RUBETEK

RUBETEK CP-1 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.