Pyronix Kudos AM 3 in 1 User manual

0C03
PYRONIX LTD
INSTALLATION
1. Remove the case lid by unscrewing the fixing screw illustrated in.
2. Remove the lens as shown in.
3. Remove the PCB, taking care not to touch the pyro sensor labeled.
4. Choose wall fixing holes, labeled and on diagram.
5. Mark wall for fixing positions (Do not route wires near mains cabling,
avoid vibrating surfaces and mount only on a solid wall)
6. Drill fixing holes
7. Fix the case to the wall.
8. Replace the PCB taking care not to touch the pyro sensor, labeled
9. Using the DIP switches (See diagram ) select the required
features and modes of operation.
10. Carry out walk test.
11. Refit the case lid and lens as shown in and
POTENTIAL FALSE ALARM HAZARDS.
1. Direct sunlight on detector
2. Pets and animals
3. Mounting detector near heaters
4. Draught’s from open windows
GB
C
H1
D3
H2
C1
C1
C2
H2
D2
H1
B2
B
A
A
B3
B1
C
D
F
E
F1
F2
F3
F4
F5
G
H
H1
H2
H1 H2 H3 H4
Power up. Normal alarm. Micowave. PIR
DIP switches (see diagram )
Note: As Factory Default all switches are ON
LED INDICATIONS
SPECIFICATIONS (QUICK REFERENCE)
Model: Kudos AM 3 in 1
Casing: White 3mm ABS Back / Front cover
0.7mm HDPE in lens area
Lens: Volumetric: 15m, 74 zones, 7 planes, 2.4m mounting height
Curtain 25m, 24 Zones, 6 planes, 5m mounting height
Long Range 45m, 46 zones, 6 planes, 2.4 mounting height
.
Detection method: Low noise dual element pyroelectric sensor + microwave
Digital signal processing: PC1, SPP+
Detection speed: 0.25 - 2.5 m/s
Operating Voltage: 9-16 VDC
Current consumption: 40mA Quiescent
@13.8V 35mA Alarm
105mA self test (short burst per test)
Relay Output: 60Vdc, 50mA (42.4Vac peak)
Mounting Height: 1.8 - 2.4m Volumetric
1.8 - 5.0m Curtain
1.8 - 2.4m Long Range
Tamper Switch: Normally closed voltage free contacts
(12V 50mA max rating)
00 0 0
Storage Temp: -40 C / 80 C (-40 F / 176 F )
0 0 0 0
Operating Temp: -30 C / 70 C (22 F / 158 F )
Emissions: EN55022 Class B
Immunity: To new European Standard EN50130-4
Accessories: Optional back tamper
PIR sensor
failed self test.
H6
Mask processing in progress.
H7
Indication of a valid mask activation.
Note:The technology
which has failed will be
indicated by a cylic flash
and pause of the LED.
H5
Microwave sensor
failed self test.
9. E- Remote LED enable terminal
To use the remote LED enable feature switch A must be in the OFF position.
9.1 Connections
To remotely enable LEDs 0 volts must be applied to the E- terminal.
9.2 Pyronix panels
Connect detector input E- to a PGM output and configure as walk test.
R
This product is approved for use in the
Residential, Commercial and Light Industrial Environment.
OPERATION OF FEATURES
1. LED Enable / Disable (Switch A)
ON = LED Enable (Override the E- control)
OFF = LED Disable (E- controls the LEDs)
ON: The detector operates in AM dual mode
OFF: The detector operates in AM PIR mode only and is intended for
use with a curtain or long range lens only.
In AM PIR mode, a triggering of the PIR causes the alarm relay to open
and the alarm LED to turn on. The PIR and Microwave LEDs are disabled.
Mask processing will work the same in both modes, i.e. the microwave signal
will be used to reset mask processing or a latched mask event
2. Operational Mode (Switch B)
OR = If either single technology detects prolonged intruder activity
5. And /Or (Switch E)
AND = Conventional dual tech, both technologies need to be
triggered simultaneously to generate an alarm.
an alarm will be generated independently.
Immunity testing carried out in AND mode.
7. Relay mode (Switch G)
ON = Relay is in normally closed mode. (N/C)
OFF = Relay is in normally open mode. (N/O)
8. 50/60 Hz (Switch H)
Factory set.
Kudos AM
3 in 1
The KUDOS AM incorporates a unique anti-masking feature which will
prevent the alarm panel from being set if an attempt to block the PIR or
Microwave coverage pattern is detected. When something moves in close
proximity to the detector an anti-mask processing sequence will be
activated. This is indicated by the Red LED which will flash at half second
intervals. Processing will normally take 60 seconds to complete and during
this time the detector mask relay output will remain closed. If the detector
verifies that an attempt to block its coverage has been made then the
appropriate relay(s) will open (according to the alarm relay mode switch).
The relay(s) will remain open until the block has been removed. In addition
the Green and Orange LEDs will turn on regardless of whether LED disable
has been selected. To reset the detector to normal operating mode, remove
the blocking material, while the RED alarm LED is flashing the detector should
be walk tested to activate both technologies. After 60 seconds the RED alarm
LED should stop flashing. When the RED Alarm LED is no longer flashing the
detector should be walk tested again to activate both technologies. Under
certain conditions it may be possible for anti-masking system not to recognise
masking of one technology only. See Options 5& 6.
NB. The above description assumes the relay mode switch G is set to
Normally Closed.
Mask sensitivity adjustment is provided by a potentiometer on the PCB.
Maximum sensitivity is achieved when the pot is turned fully clockwise.
To disable the anti-masking feature the pot should be turned fully counter
3. Mask (Switch C)
ON = Only mask relay opens and stays open upon mask processing
concluding a genuine mask situation has occurred.
OFF = Mask and alarm relays open and stay open upon mask processing
concluding a genuine mask situation has occurred.
ANTI - MASKING Refer to
MASK - ADJUSTMENT Refer to
F3
C
clockwise.
.
RINS845-3
This product complies with TS50131-2-4. at security grade 3,
environmental class 2.
UK = Suitable for use with systems installed to PD6662:2004 (AMD)
EXPORT = Suitable for use with systems installed to EN50131-1
SWITCH FEATURE POSITION MEANING
A LED Enable ON LED Enable
OFF LED Disable
B Operational ON Dual Tech Mode
Mode
OFF AM PIR Mode
C Mask Relay ON Open Mask relay
Action only when in mask
OFF Open Mask and Alarm
relay when in mask
D PIR ON SPP+
Processing
OFF PC1
E AND/OR ON AND mode is functional
OFF OR mode is functional
F Mask ON Normal Anti Mask Security Mode
Security Mode
(Anti-Block) OFF High Anti Mask Security Mode
G Relay Mode ON Relays Normally Closed
OFF Relays Normally Open
H Frequency of ON 50Hz
Operation
OFF 60Hz
4. PIR Signal Processing (Switch D) refer to
PC1 = One detection zone must be crossed
SPP+ = Two opposing detection zones must be crossed
E
6. Mask Security Mode (Switch F)
ON = Normal Anti Mask Security Mode
OFF = High Anti Mask Security Mode
Single Technology Masking can be prevented by using the Normal/High Anti
Mask Security Mode function. Switch F to OFF (Anti-Block)
When this mode is selected the RT input must be connected to a control
panel programmable (PGM) output.
When the panel is disarmed this input must be at 0V. When the panel is
armed the input must switch to 12V.
If an attempt to mask the detector is made during a disarmed state, then the
alarm relay will be held open until the detector masking is removed.
This fault is displayed as shown in diagram H7.
65mm 55mm
155mm
WEIGHTS AND
DIMENSIONS
Kg
79.2 g
Weights And Dimensions
Coverage Patterns
15m Volumetric Lens
25m Curtain Lens
45m Long Range Lens
Board Layout
Mounting & Cable Entry
PIR Detection Methods
Wiring to Control Panel
Remote LED Enable
Tamper Operation
Mask Operation
Normally Closed Operation
Normally Open Operation
Optional Tamper Unit
Front Cover & Lenses
Removing Cover
Removing Lens
Diagrams
WARRANTY
This product is sold subject to our standard warranty conditions and is warranted against defects in
workmanship for a period of two years. In the interest of continuing improvement of quality, customer care and design,
Pyronix Ltd reserve the right to amend specifications without giving prior notice.
Single technology masking can be prevented by switching switch E to OFF
(OR mode is functional).
TS50131-2-4
EN50131-1
PD6662:2004
Security Grade 3
Environmental Class 2
Pyronix Limited
Pyronix House
Braithwell Way
Hellaby, Rotherham
S66 8QY, ENGLAND
Customer Support:
+44(0)845 6434 999 (local rate)
or +44(0)1709 535225
Hours: Mon to Fri, 8:00am till 6:30pm
Email: customer[email protected]
Website: www.pyronix.com
Switch
F
PC1
SPP+
OFF
ON
D
D1
NOTE:
D2 and D3 have
been designed to
allow the detector
to be mounted in
a corner,
45 degrees to
a wall or flat
against a wall.
MOUNTING AND
CABLE ENTRY KNOCKOUTS
D2
D3
C1
C2
C2
C
On Off
Dip Switches
On Off
Dip Switches
Optional
rear tamper
Tamper
Switch
Mask
Adjustment
Microwave
adjustment
LED Enable
Dual Tech
Open Mask
SPP+
AND
Normal Anti-Block
Relay N/C
50Hz
LED Disable
AM PIR Mode
Open Mask & Alarm
PC1
OR
High Anti-Block
Relay N/O
60Hz
Orange LED =
microwave
Red LED = Alarm
Green LED = PIR
BOARD LAYOUT
PYRO
SENSOR
A
A
+-N
NC
CTTRT E-
B
B
C
C
D
D
E
E
F
F
G
G
H
H
ALARM MASK
NOTE:
Microwave adjustment
= 5 to 15m.
Mask adjustment
= 0 to 1.0 m
0.8m
1.3m
2.3m
3.8m
6.0m
6.6m
10.5m
11.0M
17.0m
45.0m
VERTICAL COVERAGE
2.4m
1m 5m
5m 15m
25m 35m
40m
15m 20m10m 25m
HORIZONTAL COVERAGE AT MAXIMUM RANGE
0.8 m
1.6m
2.0m
2.6m
3.4m
4.4m
5.8m
7.7m
11.0m
VERTICAL COVERAGE
25m VERTICAL CURTAIN LENS
HORIZONTAL COVERAGE AT MINIMUM RANGE
B2
O
20
24 zones
6 planes
2.4m
5m
3m
0m
2m
2m
2m
2m
1m
1m
1m
1m
0m
3m
3m
3m
15m VOLUMETRIC LENS
B
B1
COVERAGE PATTERN AND PLAN VIEW
45m LONG RANGE LENS
B3
HORIZONTAL COVERAGE
18m
0m
17m
16m
15m
14m
13m
12m
11m
10m
9m
8m
7m
6m
5m
4m
3m
2m
1m
1m
2m
3m
4m
5m
6m
7m
8m
9m
10m
11m
12m
13m
14m
15m
16m
17m
18m 1m 10m 20m 30m 45m
O
90
46 zones
6 planes
HORIZONTAL COVERAGE
VERTICAL COVERAGE
15m
5m
1m
2m
3m 4m
5m
5m 6m 7m
8m
9m
11m 12m 13m
14m
15m
1m 10m
10m
2.4m
O
85
74 zones
7 planes
15m
1m 10m
REMOVING AND REPLACEMENT OF FRONT COVER AND LENSES.
H
H1 H2
REMOVING THE LENS:
With the front cover
removed,unclip the
lens as shown above.
NOTE:
When removing the
front cover leave the
screw in place
REPLACING THE LENS:
Locate the lens by hooking onto
the three bottom pegs and push
the lens into position, ensuring that
the lens is secure via the side and
top clips.
0.3 - 3.0 m/s
1 2 3
SPP+
PC 1
PIR DETECTION METHODS
PC 1 = One detection zone must be crossed.
SPP+ = Two opposing detection zones must be crossed.
F
E
G
T T
N C
N C
N C N C
T T
F2
F3
NORMAL
NO MASK ACTIVATION
TAMPER ALARM
MASK ACTIVATION SWITCH C OFF
MASK ACTIVATION SWITCH C ON
TAMP PGM
RT
PGM
WALK TEST
12V
50mA
60V
50mA
Remote
LED
enable
Set/
Unset
Alarm
Relay
Mask
Relay
60V
50mA
9 - 16Vdc
35mA
@12Vdc
ALARM
ZONE
MASK
ZONE
RT E-
T
T
C
C N
N
WIRING TO CONTROL PANEL
F1
MASK
MASK
ALARM
MASK
TAMPER OPERATION
MASK OPERATION
D
F4
F5
NORMAL
NORMALLY CLOSED OPERATION
NORMALLY OPEN OPERATION
NORMAL
NO
ALARM
ALARM
NO
1
1
1A
1A
1B
1B
1C
1C
2
2
3
3
3A
3A
3B
3B
4
4
5
5
6
6
7
OPTIONAL TAMPER UNIT
Note: The Kudos detector may be fitted with an optional back tamper, which is sold separately.
C
7
ntlt
in
Is
a
l
ao
nnwi c e
Mou ti g th ba k tamp r
Fl t aa
aag inst a wll
re
ue
C
onrm
on
td
5ge o wa
l
4 D
ere n l
u u h a i o
C t o t t e tmper pos ti n
u dss lr
req ire , u ing calpe o
s atyi
h rp u ilit kn fe
iit p n t
Or entaton of am er u i
edie
L ft han s d
ih ai
R
gt
hn
d
sd
e
E sr m r s i
nu e ta pe wtch lever
c rr c e
is o e tly orintated
P s t n t h ae
o i io swi c and t mpr
le
p
at
.
ti n n w hn t ,
Posi o u it it i deector
n s p re fo
usi g te th e, r
o ntnf i
rie ta io o un t.
nu e i s r
Es r clip f xture a e
l e i th c r c
ocat d n e ore t
oio,
t o eps
t
inonhe utr
fa f ea g
sur ce o th c sin .
Frequencies Countries
AT, BE, CH, CY, CZ,
DK, FI, FR, GR, HU, IE,
IS, IT, LT, MT, NL, PL,
SI, TR
BE, CH, CY, DK, HU,
IE, IS, IT, MT, NL, NO,
SE, SI
GB
9.9Ghz
10.5Ghz
10.6Ghz
This product operates is a
European non-harmonised
frequency band
Hereby, Pyronix, declares that this Kudos AM 3 in 1
is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC.
The declaration of conformity may be consulted at
www.pyronix.com/DoC
!

Other Pyronix Security Sensor manuals

Pyronix PCX 46 APP Owner's manual

Pyronix

Pyronix PCX 46 APP Owner's manual

Pyronix Kudos User manual

Pyronix

Pyronix Kudos User manual

Pyronix XDL15TT-AM User manual

Pyronix

Pyronix XDL15TT-AM User manual

Pyronix KX10DP User manual

Pyronix

Pyronix KX10DP User manual

Pyronix ENFORCER V11 User manual

Pyronix

Pyronix ENFORCER V11 User manual

Pyronix KX10DP-WE User manual

Pyronix

Pyronix KX10DP-WE User manual

Pyronix KX12DQ-WE User manual

Pyronix

Pyronix KX12DQ-WE User manual

Pyronix XDH10TT-WE User manual

Pyronix

Pyronix XDH10TT-WE User manual

Pyronix KX15DD User manual

Pyronix

Pyronix KX15DD User manual

Pyronix Kudos DT User manual

Pyronix

Pyronix Kudos DT User manual

Pyronix XDL12TT-WB User manual

Pyronix

Pyronix XDL12TT-WB User manual

Pyronix FPKX15DT2 User manual

Pyronix

Pyronix FPKX15DT2 User manual

Pyronix KX15DC-WE User manual

Pyronix

Pyronix KX15DC-WE User manual

Pyronix EQUINOX AM+ User manual

Pyronix

Pyronix EQUINOX AM+ User manual

Pyronix HomeControl+ Installation and operating manual

Pyronix

Pyronix HomeControl+ Installation and operating manual

Pyronix KX15DQ User manual

Pyronix

Pyronix KX15DQ User manual

Pyronix KX10DP User manual

Pyronix

Pyronix KX10DP User manual

Pyronix HIKVISION SMOKE-WE User manual

Pyronix

Pyronix HIKVISION SMOKE-WE User manual

Pyronix KX10DP User manual

Pyronix

Pyronix KX10DP User manual

Pyronix KX15DQ User manual

Pyronix

Pyronix KX15DQ User manual

Pyronix XD10TTAM User manual

Pyronix

Pyronix XD10TTAM User manual

Pyronix BREAKGLASS 2000 User manual

Pyronix

Pyronix BREAKGLASS 2000 User manual

Pyronix KX10DP User manual

Pyronix

Pyronix KX10DP User manual

Pyronix KX10DTP User manual

Pyronix

Pyronix KX10DTP User manual

Popular Security Sensor manuals by other brands

GEZE GC 173 Supplementary sheet

GEZE

GEZE GC 173 Supplementary sheet

hager H 400 User instructions

hager

hager H 400 User instructions

GST C-9103 manual

GST

GST C-9103 manual

Teledyne 340CF ELSD Installation and operation guide

Teledyne

Teledyne 340CF ELSD Installation and operation guide

Visonic NEXT CAM PG2 installation instructions

Visonic

Visonic NEXT CAM PG2 installation instructions

Gira System 3000 5373 Series operating instructions

Gira

Gira System 3000 5373 Series operating instructions

Satel micra MXD-300 manual

Satel

Satel micra MXD-300 manual

Ness Quantum Pet aware Dual Installation notes

Ness

Ness Quantum Pet aware Dual Installation notes

North American Rescue Talon 60-0027 Instrcutions for use

North American Rescue

North American Rescue Talon 60-0027 Instrcutions for use

THORLABS PDA100A2 user guide

THORLABS

THORLABS PDA100A2 user guide

General Photonics BPD-002-OEM-400-15 Instructions Note

General Photonics

General Photonics BPD-002-OEM-400-15 Instructions Note

Alula RE110P install guide

Alula

Alula RE110P install guide

TimeTec Water Leak Detector user guide

TimeTec

TimeTec Water Leak Detector user guide

SWARCO IG325/2 user manual

SWARCO

SWARCO IG325/2 user manual

logika WL-ZSPWBPWBPW-PI11-04 product manual

logika

logika WL-ZSPWBPWBPW-PI11-04 product manual

Thermocable ProReact EN Analogue installation instructions

Thermocable

Thermocable ProReact EN Analogue installation instructions

Vision ZP3102MY-5 Installation & operation manual

Vision

Vision ZP3102MY-5 Installation & operation manual

Smartwares RM640K manual

Smartwares

Smartwares RM640K manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.